Hostname: page-component-8448b6f56d-42gr6 Total loading time: 0 Render date: 2024-04-20T03:08:07.548Z Has data issue: false hasContentIssue false

An institutional review of the value of computed tomographic angiography in the diagnosis of congenital cardiac malformations

Published online by Cambridge University Press:  14 April 2005

Arun Chandran
Affiliation:
Departments of Pediatric Cardiology and Radiology, University of Florida College of Medicine, Gainesville, Florida, United States of America
F. Jay Fricker
Affiliation:
Departments of Pediatric Cardiology and Radiology, University of Florida College of Medicine, Gainesville, Florida, United States of America
Kenneth O. Schowengerdt
Affiliation:
Departments of Pediatric Cardiology and Radiology, University of Florida College of Medicine, Gainesville, Florida, United States of America
William A. Cumming
Affiliation:
Departments of Pediatric Cardiology and Radiology, University of Florida College of Medicine, Gainesville, Florida, United States of America
Arwa Saidi
Affiliation:
Departments of Pediatric Cardiology and Radiology, University of Florida College of Medicine, Gainesville, Florida, United States of America
Carolyn T. Spencer
Affiliation:
Departments of Pediatric Cardiology and Radiology, University of Florida College of Medicine, Gainesville, Florida, United States of America
Joseph Paolillo
Affiliation:
Departments of Pediatric Cardiology and Radiology, University of Florida College of Medicine, Gainesville, Florida, United States of America
Margaret M. Samyn
Affiliation:
Departments of Pediatric Cardiology and Radiology, University of Florida College of Medicine, Gainesville, Florida, United States of America

Abstract

The ultra-fast, thin-cut computerised tomographic angiogram is an efficient method to diagnose extracardiac lesions associated with congenital cardiac disease. For the purposes of this review, we evaluated various facets of the technique as used in 30 patients who were referred for diagnosis of congenital cardiac disease. The technique had high diagnostic accuracy, with a sensitivity of 93 percent in 15 of these patients referred for either interventional catheterisation or surgery. There were no immediate side-effects associated with the scanning procedure. The scan was also found to be more cost-effective as compared to an alternative noninvasive modality for imaging modality, namely magnetic resonance imaging. The angiographic technique, however, does expose the child to between 2 and 2.5 rems of radiation, despite the short period of scanning, of 10 plus or minus 2 seconds.

Type
Original Article
Copyright
2005 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Hopkins KL. Pediatric great vessel anomalies: initial clinical experience with spiral computer tomography angiography. Radiology 1996; 200: 811815.Google Scholar
Katz M, Konen E, Rozenman J, Szeinberg A, Itzchak Y. Spiral computer tomography and 3D image reconstruction of vascular rings and associated tracheobronchial anomalies. J Comput Assist Tomogr 1995; 19: 564568.Google Scholar
Becker C, Soppa C, Fink U, et al. Spiral computer tomographic angiography and 3-dimensional reconstruction in patients with aortic coarctation. Eur Radiol 1997; 7: 14731477.Google Scholar
Kaemmerer H, Mugge A, Oelert F, et al. Evaluation of the aorta and supra-aortic vessels with spiral computer tomography and 3-dimensional vascular reconstruction after operation of aortic isthmus stenosis. Z Kardiol 1994; 83: 775783.Google Scholar
Shiraishi I, Kato Y, Todoroki H, Satoh H, Hamaoka K. Differential color imaging technique of helical computer tomographic angiography in the diagnosis of total anomalous pulmonary venous drainage. Circulation 2000; 101: 20172018.Google Scholar
Tsai-Goodman B, Geva T, Odegard KC, Sena LM, Powell AJ. Clinical role, accuracy, and technical aspects of cardiovascular magnetic resonance imaging in infants. Am J Cardiol 2004; 94: 6974.Google Scholar
Odegard KC, DiNardo JA, Tsai-Goodman B, et al. Anesthesia considerations for cardiac magnetic resonance imaging in infants and small children. Paediatr Anaesth 2004; 14: 471476.Google Scholar
Pihkala J, Nykanen D, Freedome RM, Benson LN. Interventional cardiac catheterisation. Pediatr Clin North Am 1999; 46: 441464.Google Scholar
Korperich H, Gieseke J, Barth P, et al. Flow volume and shunt quantification in pediatric congenital heart disease by real-time magnetic resonance velocity mapping: a validation study. Circulation 2004; 109: 19871993.Google Scholar
Razavi RS, Hill DL, Muthurangu V, et al. Three-dimensional magnetic resonance imaging of congenital cardiac anomalies. Cardiol Young 2003; 13: 461465.Google Scholar
Geva T, Sandweiss BM, Gauvreau K, Lock JE, Powell AJ. Factors associated with impaired clinical status in long-term survivors of tetralogy of Fallot repair evaluated by magnetic resonance imaging. J Am Coll Cardiol 2004; 43: 10681074.Google Scholar
Pignatelli RH, McMahon CJ, Chung T, Vick GW III. Role of echocardiography versus magnetic resonance imaging for the diagnosis of congenital heart disease. Curr Opin Cardiol 2003; 18: 357365.Google Scholar
Boxt LM. Magnetic resonance and computed tomographic evaluation of congenital heart disease. J Magn Reson Imaging 2004; 19: 827847.Google Scholar
Siegel MJ. Multiplanar and three-dimensional multi-detector row computer tomography of thoracic vessels and airways in the pediatric population. Radiology 2003; 229: 641650.Google Scholar
Lee ED, Siegel MJ, Hildebolt CF, et al. Multidetector computer tomography evaluation of thoracic aortic anomalies in pediatric patients and young adults: comparison of axial, multiplanar, and 3-dimensional images. Am J Roentgenol 2004; 182: 777784.Google Scholar
Lawler LP, Fishman EK. Multi-detector row computer tomography of thoracic disease with emphasis on 3-dimensional volume rendering and computer tomographic angiography. Radiographics 2001; 21: 12571273.Google Scholar
Frush DP, Donnelly LF, Rosen NS. Computed tomography and radiation risks: what pediatric health care providers should know. Pediatrics 2003; 112: 951957.Google Scholar
Giesler T, Baum U, Ropers D, et al. Non invasive visualization of coronary arteries using contrast enhanced multi-detector computer tomography: influence of heart rate on image quality and stenosis detection. Am J Roentgenol 2002; 179: 911916.Google Scholar
Nieman K, Rensing BJ, van Geuns RJ, et al. Non-invasive cardiac angiography with multi-slice spiral computed tomography: impact of heart rate. Heart 2002; 88: 470474.Google Scholar