Hostname: page-component-747cfc64b6-nvdzj Total loading time: 0.347 Render date: 2021-06-15T17:03:37.843Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": true, "newCiteModal": false, "newCitedByModal": true, "newEcommerce": true }

Late manifestation coarctation of the aorta in a premature infant 4-month post-percutaneous device closure of a patent ductus arteriosus

Published online by Cambridge University Press:  25 November 2019

Ryan M. Serrano
Affiliation:
Department of Pediatric Cardiology and Department of Pediatric Cardiothoracic Surgery, Riley Hospital for Children, Indianapolis, IN, USA
Mark D. Rodefeld
Affiliation:
Department of Pediatric Cardiology and Department of Pediatric Cardiothoracic Surgery, Riley Hospital for Children, Indianapolis, IN, USA
Ryan Alexy
Affiliation:
Department of Pediatric Cardiology and Department of Pediatric Cardiothoracic Surgery, Riley Hospital for Children, Indianapolis, IN, USA
Corresponding
E-mail address:

Abstract

Patent ductus arteriosus is the most common cardiovascular abnormality in premature infants. With newly available percutaneous devices, centres are reporting high rates of success and favourable safety profiles with percutaneous closure of haemodynamically significant ductus arteriosi in infants under 1000 g. We report the case of a 5-week-old, previous 25-week gestation, 1200-g infant who underwent successful percutaneous closure of a ductus arteriosus with a Medtronic Microvascular Plug but who developed late-term coarctation from the device. This case should prompt practitioners to consider the need and timing of follow-up echocardiograms in this population and sheds light on a newly reported long-term complication of device closure in premature infants.

Type
Brief Report
Copyright
© Cambridge University Press 2019 

Access options

Get access to the full version of this content by using one of the access options below.

References

Chiruvolu, A, Punjwani, P, Ramaciotti, C. Clinical and echocardiographic diagnosis of patent ductus arteriosus in premature neonates. Early Hum Dev 2009; 85: 147149.CrossRefGoogle ScholarPubMed
Noori, S, Friedlich, P, Seri, I. Patent ductus arteriosus in the preterm infant: to treat or not to treat? J Perinatol 2010; 30: S31S37.CrossRefGoogle ScholarPubMed
Ogando, AR, Asensio, IP, Sanchez de la blanca, AR, et al. Surgical ligation versus percutaneous closure of patent ductus arteriosus in very low-weight preterm infants: which are the real benefits of the percutaneous approach? Pediatr Cardiol 2018; 39: 398410.CrossRefGoogle Scholar
Wang-Giuffre, EW, Breinholt, J. Novel use of the Medtronic micro vascular plug for PDA closure in preterm infants. Catheter Cardiovasc Interv 2017; 89: 10591065.CrossRefGoogle ScholarPubMed
Sathanandam, S, Justino, H, Warrer, BR 3rd, et al. Initial clinical experience with the Medtronic Micro Vascular Plug in transcatheter occlusion of PDAs in extremely premature infants. Catheter Cardiovasc Interv 2017; 89: 10511058.CrossRefGoogle ScholarPubMed
Pamukcu, O, Tuncay, A, Narin, N, et al. Patent ductus arteriosus closure in preterms less than 2 kg: surgery versus transcatheter. Int J Cardiol 2018; 250: 110115.CrossRefGoogle ScholarPubMed
Zahn, EM, Peck, D, Phillips, A, et al. Transcatheter closure of patent ductus arteriosus in extremely premature newborns early results and midterm-follow up. J Am Coll Cardiol Intv 2016; 9: 24292437.CrossRefGoogle ScholarPubMed
3
Cited by

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Late manifestation coarctation of the aorta in a premature infant 4-month post-percutaneous device closure of a patent ductus arteriosus
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Late manifestation coarctation of the aorta in a premature infant 4-month post-percutaneous device closure of a patent ductus arteriosus
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Late manifestation coarctation of the aorta in a premature infant 4-month post-percutaneous device closure of a patent ductus arteriosus
Available formats
×
×

Reply to: Submit a response

Please enter your response.

Your details

Please enter a valid email address.

Conflicting interests

Do you have any conflicting interests? *