Feasibility of customised unipolar conversion using bipolar temporary pacing wires in patients after surgical repair of congenital heart disease

Published online by Cambridge University Press:  20 August 2013

Bjoern Peters
Affiliation:
Department of Congenital Heart Disease and Pediatric Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany
Oliver Miera
Affiliation:
Department of Congenital Heart Disease and Pediatric Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany
Peter Ewert
Affiliation:
Department of Congenital Heart Disease and Pediatric Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany
Sevim Yilmaz
Affiliation:
Department of Congenital Heart Disease and Pediatric Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany
Felix Berger
Affiliation:
Department of Congenital Heart Disease and Pediatric Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany
Boris Schmitt
Affiliation:
Department of Congenital Heart Disease and Pediatric Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany
Corresponding
E-mail address:

Abstract

Objective: Temporary pacing wires play a crucial role in the diagnosis and therapy of post-operative arrhythmia after surgery for congenital heart disease. At present, bipolar pacing wires are used in most institutions. In case of functional failure of these wires, a unipolar mode of stimulation and sensing should be theoretically possible as a rescue procedure. Methods: We tested the feasibility of the customised unipolar mode in 18 post-operative patients with congenital heart disease (age 9.2 ± 13.9 months, weight 6.3 ± 3.8 kg, and cardiopulmonary bypass time 70 ± 29 minutes). As there are two possible unipolar configurations, there are twice the number of testing parameters; of those, we compared sensing (mV) and pacing thresholds (V at 0.5 ms). Results: Atrial sensing was significantly better in the unipolar modes (p < 0.001, p < 0.003). The ventricular unipolar sensing did not differ significantly in the “better” of the two possible configurations from the bipolar values (p = 0.363). For the unipolar pacing thresholds, only the “better” unipolar configuration did not differ significantly from the bipolar measurements (atrial: p = 0.058, ventricular: p = 0.138). There was no exit block or undersensing. Conclusion: The results demonstrate that unipolar stimulation and sensing using bipolar epicardial temporary pacing wires is feasible. In the case of failure of bipolar temporary pacing wires, this modality represents an easy rescue measure that in such cases should always be considered.

Type
Original Articles
Copyright
Copyright © Cambridge University Press 2013 

Access options

Get access to the full version of this content by using one of the access options below.

References

1. Batra, AS, Balaji, S. Post operative temporary epicardial pacing: when, how and why? Ann Pediatr Cardiol 2008; 1: 120125.CrossRefGoogle Scholar
2. Wirtz, S, Schulte, HD, Winter, J, Godehardt, E, Kunert, J. Reliability of different temporary myocardial pacing leads. Thorac Cardiovasc Surg 1989; 37: 163168.CrossRefGoogle ScholarPubMed
3. Yiu, P, Tansley, P, Pepper, JRA. Improved reliability of post-operative ventricular pacing by use of bipolar temporary pacing leads. Cardiovasc Surg 2001; 9: 391395.CrossRefGoogle ScholarPubMed
4. Elmi, F, Tullo, NG, Khalighi, K. Natural history and predictors of temporary epicardial pacemaker wire function in patients after open heart surgery. Cardiology 2002; 98: 175180.CrossRefGoogle Scholar
5. Rusanov, A, Spotnitz, HM. Salvage of a failing bifurcated bipolar epicardial lead with conductor fracture. Ann Thorac Surg 2010; 90: 649651.CrossRefGoogle ScholarPubMed
6. Paul, T, Luhmer, I, Wilken, M, Kallfelz, HC. Emergency 12-hour transesophageal stimulation in a 21-month-old infant. Anaesthesist 1993; 42: 564566.Google Scholar
7. Hessling, G, Brockmeier, K, Ulmer, HE. Transesophageal electrocardiography and atrial pacing in children. J Electrocardiol 2002; 35 (Suppl): 143149.CrossRefGoogle ScholarPubMed
8. Kohler, H, Zink, S, Scharf, J, Koch, A. Severe esophageal burn after transesophageal pacing. Endoscopy 2007; 39 (Suppl 1): E300.CrossRefGoogle ScholarPubMed
9. Knilians, TK. Arrhythmia. In: Wheeler DS, Wong HR, Shanley, TP (eds.). Pediatric Critical Care Medicine: Basic Science and Clinical Evidence, Springer, London, 2007: 785–796.Google Scholar
10. Lee, KL, Lau, CP, Tse, HF, et al. First human demonstration of cardiac stimulation with transcutaneous ultrasound energy delivery: implications for wireless pacing with implantable devices. J Am Coll Cardiol 2007; 50: 877883.CrossRefGoogle ScholarPubMed
11. Valsangiacomo, E, Schmid, ER, Schupbach, RW, et al. Early postoperative arrhythmias after cardiac operation in children. Ann Thorac Surg 2002; 74: 792796.CrossRefGoogle ScholarPubMed
12. Rekawek, J, Kansy, A, Miszczak-Knecht, M, et al. Risk factors for cardiac arrhythmias in children with congenital heart disease after surgical intervention in the early postoperative period. J Thorac Cardiovasc Surg 2007; 133: 900904.CrossRefGoogle ScholarPubMed
13. Bar-Cohen, Y, Silka, MJ. Management of postoperative arrhythmias in pediatric patients. Curr Treat Options Cardiovasc Med 2012; 14: 443454.CrossRefGoogle ScholarPubMed
14. Ceresnak, SR, Pass, RH, Starc, TJ, et al. Predictors for hemodynamic improvement with temporary pacing after pediatric cardiac surgery. J Thorac Cardiovasc Surg 2011; 141: 183187.CrossRefGoogle ScholarPubMed

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Feasibility of customised unipolar conversion using bipolar temporary pacing wires in patients after surgical repair of congenital heart disease
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Feasibility of customised unipolar conversion using bipolar temporary pacing wires in patients after surgical repair of congenital heart disease
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Feasibility of customised unipolar conversion using bipolar temporary pacing wires in patients after surgical repair of congenital heart disease
Available formats
×
×

Reply to: Submit a response


Your details


Conflicting interests

Do you have any conflicting interests? *