We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To send content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about sending content to .
To send content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about sending to your Kindle.
Note you can select to send to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
An electronic surveillance tool was developed for CAUTI and urinary catheter utilization based on the objective components of the National Healthcare Safety Network (NHSN) definitions including fever, urinalysis, and urine culture. Results were compared to manual chart review by an infection preventionist (IP).
Results.
During January and February 2010, 204 positive urine cultures (≥103 colony-forming units/mL) were identified in 136 patients with indwelling urinary catheters during their hospitalization. The electronic surveillance tool detected 60 CAUTI cases and 7,098 catheter-days, yielding a CAUTI incidence rate of 8.5 per 1,000 catheter-days. Urinary catheter utilization ratios (Foley-days/patient-days) were: acute care units, 0.27 (3,637 of 13,229); intensive care units, 0.77 (3,461 of 4,469); and overall, 0.40 (7,098 of 17,698). In comparison, the IP identified 59 cases by manual review with a sensitivity of 51 of 59 (86.4%), specificity 136 of 145 (93.8%), and negative predictive value of 136 of 144 (94.4%). Fever was present in 54 of 59 (91.5%) of CAUTI cases identified manually, while subjective criteria were documented in only 6 of 59 (10.2%) infections. Agreement between the electronic surveillance and manual IP review was assessed as very good (k, 0.80; 95% confidence interval, 0.71–0.89).
Conclusions.
We report an attempt at automating surveillance for CAUTI. With a high negative predictive value, the electronic tool allows for more efficient CAUTI surveillance and facilitates housewide trending of rates and catheter utilization. This approach should be validated in different patient populations.