We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To send content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about sending content to .
To send content items to your Kindle, first ensure no-reply@cambridge.org
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about sending to your Kindle.
Note you can select to send to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Both transposition of the great arteries (TGA) previously submitted to a Senning/Mustard procedure and congenitally corrected TGA (cc-TGA) have the systemic circulation supported by the morphological right ventricle, thereby rendering these patients to heart failure events risk. The aim of this study was to evaluate cardiopulmonary exercise test parameters for stratifying the risk of heart failure events in TGA patients.
Methods:
Retrospective evaluation of adult TGA patients with systemic circulation supported by the morphological right ventricle submitted to cardiopulmonary exercise test in a tertiary centre. Patients were followed up for at least 1 year for the primary endpoint of cardiac death or heart failure hospitalisation. Several cardiopulmonary exercise test parameters were analysed as potential predictors of the combined endpoint and their predictive power were compared (area under the curve).
Results:
Cardiopulmonary exercise test was performed in 44 TGA patients (8 cc-TGA), with a mean age of 35.1 ± 8.4 years. The primary endpoint was reached by 10 (22.7%) patients, with a mean follow-up of 36.7 ± 26.8 months. Heart rate at anaerobic threshold had the highest area under the curve value (0.864), followed by peak oxygen consumption (pVO2) (0.838). Heart rate at anaerobic threshold ≤95 bpm and pVO2 ≤20 ml/kg/min had a sensitivity of 87.5 and 80.0% and a specificity of 82.4 and 76.5%, respectively, for the primary outcome.
Conclusion:
Heart rate at anaerobic threshold ≤95 bpm had the highest predictive power of all cardiopulmonary exercise test parameters analysed for heart failure events in TGA patients with systemic circulation supported by the morphological right ventricle.
Bicuspid aortic valve is the most common CHD. Its association with early valvular dysfunction, endocarditis, thoracic aorta dilatation, and aortic dissection is well established.
Objective
The aim of this study was to assess the incidence and predictors of cardiac events in adults with bicuspid aortic valve.
Methods
We carried out a retrospective analysis of cardiac outcomes in ambulatory adults with bicuspid aortic valve followed-up in a tertiary hospital centre. Outcomes were defined as follows: interventional – intervention on the aortic valve or thoracic aorta; medical – death, aortic dissection, aortic valve endocarditis, congestive heart failure, arrhythmias, or ischaemic heart disease requiring hospital admission; and a composite end point of both. Kaplan–Meier curves were generated to determine event rates, and predictors of cardiac events were determined by multivariate analysis.
Results
A total of 227 patients were followed-up over 13±9 years; 29% of patients developed severe aortic valve dysfunction and 12.3% reached ascending thoracic aorta dimensions above 45 mm. At least one cardiac outcome occurred in 38.8% of patients, with an incidence rate at 20 years of follow-up of 47±4%; 33% of patients were submitted to an aortic valve or thoracic aorta intervention. Survival 20 years after diagnosis was 94±2%. Independent predictors of the composite end point were baseline moderate–severe aortic valve dysfunction (hazard ratio, 3.19; 95% confidence interval, 1.35–7.54; p<0.01) and aortic valve leaflets calcification (hazard ratio, 4.72; 95% confidence interval, 1.91–11.64; p<0.005).
Conclusions
In this study of bicuspid aortic valve, the long-term survival was excellent but with occurrence of frequent cardiovascular events. Baseline aortic valve calcification and dysfunction were the only independent predictors of events.
The role of right ventricular longitudinal strain for assessing patients with repaired tetralogy of Fallot is not fully understood. In this study, we aimed to evaluate its relation with other structural and functional parameters in these patients.
Methods
Patients followed-up in a grown-up CHD unit, assessed by transthoracic echocardiography, cardiac MRI, and treadmill exercise testing, were retrospectively evaluated. Right ventricular size and function and pulmonary regurgitation severity were assessed by echocardiography and MRI. Right ventricular longitudinal strain was evaluated in the four-chamber view using the standard semiautomatic method.
Results
In total, 42 patients were included (61% male, 32±8 years). The mean right ventricular longitudinal strain was −16.2±3.7%, and the right ventricular ejection fraction, measured by MRI, was 42.9±7.2%. Longitudinal strain showed linear correlation with tricuspid annular systolic excursion (r=−0.40) and right ventricular ejection fraction (r=−0.45) (all p<0.05), which in turn showed linear correlation with right ventricular fractional area change (r=0.50), pulmonary regurgitation colour length (r=0.35), right ventricular end-systolic volume (r=−0.60), and left ventricular ejection fraction (r=0.36) (all p<0.05). Longitudinal strain (β=−0.72, 95% confidence interval −1.41, −0.15) and left ventricular ejection fraction (β=0.39, 95% confidence interval 0.11, 0.67) were independently associated with right ventricular ejection fraction. The best threshold of longitudinal strain for predicting a right ventricular ejection fraction of <40% was −17.0%.
Conclusions
Right ventricular longitudinal strain is a powerful method for evaluating patients with tetralogy of Fallot. It correlated with echocardiographic right ventricular function parameters and was independently associated with right ventricular ejection fraction derived by MRI.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.