Hostname: page-component-8448b6f56d-cfpbc Total loading time: 0 Render date: 2024-04-19T20:36:19.863Z Has data issue: false hasContentIssue false

Reprocessing of single-use medical devices and their associated problems: an experience from a cancer center in eastern India

Published online by Cambridge University Press:  16 March 2020

Debabrata Basu*
Affiliation:
Central Sterile Supply Department, Tata Medical Center, Kolkata, India
Mousumi Dhara
Affiliation:
Materials Department, Tata Medical Center, Kolkata, India
Sanjay Kishore Dutta
Affiliation:
Central Sterile Supply Department, Tata Medical Center, Kolkata, India
*
Author for correspondence: Debabrata Basu, E-mail: debabrata.basu@tmckolkata.com
Rights & Permissions [Opens in a new window]

Abstract

Type
Letter to the Editor
Copyright
© 2020 by The Society for Healthcare Epidemiology of America. All rights reserved

To the Editor—Transmission of infectious agents can occur through unclean and unsterile medical devices. Breakdown of sterility of medical devices may lead to the transmission of bacterial and viral pathogens, including those associated with multidrug resistance. Costly medical devices must be reprocessed, and the decontamination process must be conducted under stringent quality control. The central sterile supply department (CSSD) plays an important role in ensuring that these medical devices are sterilized and delivered to various users in the hospital in a quality-assured environment. Here, we discuss the reprocessing of so-called single-use medical devices (SUDs) in a hospital CSSD as well as some advantages and limitations of cleaning, disinfection, and sterilization. Reference Allison1

Complex instrument design

Many instruments are available in the medical supply market that cannot be cleaned and sterilized properly due to their complex design; nevertheless, they are declared reusable. Basically, surgical instruments are divided into 2 categories: heat-resistant (metallic) and heat sensitive (nonmetallic, eg, rubber or plastic) where difficulty of reprocessing based on their geometric design (ie, outside shape, lumen, surface, valves and seals), the material used (ie, chemical property, passive layer, corrosion properties and thermal stability), and their construction (eg, ease of disassembly or dead-end areas). Reference Sebben2 However, the reprocessing of nonmetallic instruments is more critical than that of metallic instruments because these instruments mainly have specialized uses. The complexities of nonmetallic instruments include their design composition (ie, splits, screws, lumen, and flushing channels), their potential for contamination due to frequent use, and their lack of thermal stability due to plastic or rubber components. Reference Mayer, Bederman, Colin, Berger, Cesario and Schwarzkopf3 Also, these devices are often manufactured with the expectation that they will be discarded after a single use.

Reprocessing difficulties

Body fluids polymerize on instrument surfaces when they are allowed to dry. Thus, instruments must remain wet in area where they are used and must be transferred immediately thereafter to the CSSD. After handover in CSSD, the surgical instruments are disassembled before cleaning. The CSSD should have enough space, with proper cleaning facilities: a manual or mechanical wash system, water jets, suitable cleaning brushes, and a good ventilation system. The instruments should be immersed completely in a neutral enzymatic where proper contact time and concentration should be measured to achieve safe and effective cleaning; electrically powered surgical instruments should not be immersed but should be wiped thoroughly. Reference Basu4 To protect instruments from disinfecting agents that fix soils (ie, aldehydes or per-acetic acid), cleaning should be done prior to disinfection so that fixation of soil can be avoided. Thorough washing then takes place using a manual or mechanical method that requires purified and pressurized water. Sterilization is conducted according to the instrument’s thermal stability and the manufacturer’s recommendations if available. Finally, monitoring and documentation should be proper for legal purposes and for future requirement. 5,Reference Basu6

Single-use device reuse policy

In every hospital, a committee makes decisions about reprocessing SUDs. Committee members from administration, infection control, central services, surgical services, materials and finance departments should have enough knowledge of reprocessing SUDs to evaluate the related legal, ethical, and economic issues. Reference Sebben2 The main reason for reprocessing SUDs is to reduce the charges to the patient, and patient consent may not be required if there is a stringent standard policy for reusing SUDs. Reference Collier7 If full charges were made for every new SUD, people from poor or developing countries would not be able to afford medical services. Reference Lee, Berzins and Alfieri8,Reference Fast, Fast, Fast, Veltjens, Salami and White9 Additional aspects related to reusing SUDs include device availability, patient safety, equipment availability, and reprocessing time or technique. Any decision to reprocess an SUD product should include a thorough review of the manufacturer’s user’s manual, including any written policies for cleaning, disinfection, and sterilization. Reference Mayer, Bederman, Colin, Berger, Cesario and Schwarzkopf3 Finally, the committee must determine the maximum number of uses for each device as well as the charge to the patient: maximum retail price of the device (MRP) divided by the number of uses.

In our 400-bed cancer center in eastern India, the number reuses is based on our hospital reuse policy and the cost of the product. If the SUD cost is ≤10,000 INR (US$142.85), the charges to the patient will be one-third of the total MRP. Similarly, if an item costs 10,000 INR, the charges will be one-fifth of the total MRP, and if an item costs 30,000 INR (~US$428.57), the charges will be one-tenth of the total MRP. Thus, the patient need not pay more than 2, 000 INR (US$28.57) to 3,000 INR (US$42.85) for a single item. Below 2,000 INR, SUDs are not reused, according to our policy. Software containing date, product name, unique code, frequency of use, and patient’s identification number is used to maintain all the records of reused SUDs and to calculate the number uses along with cost.

In conclusion, the CSSD represents a neglected area of the infection control system in a hospital. Investment in well-equipped CSSD infrastructure is necessary for the smooth functioning of a hospital. Resources should be directed not only toward the development of physical infrastructure and the equipment in the CSSD but also toward the recruitment and retention of technically qualified personnel who are able to operate the system effectively. Every CSSD technician must know the importance of infection control and thoroughly understand their role in the process. Ensuring effective functioning of the CSSD is essential for infection prevention in any hospital. Reference Fast, Fast, Fast, Veltjens, Salami and White9

Acknowledgments

None.

Financial support

No financial support was provided relevant to this article.

Conflicts of interest

All authors report no conflicts of interest relevant to this article.

References

Allison, VD. Hospital central sterile supply departments. Br Med J 1960;2:772778.CrossRefGoogle ScholarPubMed
Sebben, JE. Sterilization and care of surgical instruments and supplies. J Am Acad Dermatol 1984;3:381392.CrossRefGoogle Scholar
Mayer, RR, Bederman, SS, Colin, VM, Berger, MM, Cesario, TC, Schwarzkopf, R. Risk of contamination in assembled versus disassembled instruments in hip arthroplasty surgery. J Arthroplasty 2016;31:17461749.CrossRefGoogle Scholar
Basu, D. The importance of chemical solutions used for cleaning stainless steel surgical instruments in the central sterile supply department. Infect Control Hosp Epidemiol 2015;36:868869.CrossRefGoogle ScholarPubMed
Guideline for disinfection and sterilization in healthcare facilities. Centers for Disease Control and Prevention website. http://www.cdc.gov/hicpac/disinfection sterilization/17 00recommendations.html. Published 2008. Accessed February 11, 2020.Google Scholar
Basu, D. Requirement of hollow process challenge device for monitoring hollow and complex instruments sterilization: a simulator for proper sterility assurance. Infection Control Hosp Epidemiol 2019;40:951952.CrossRefGoogle ScholarPubMed
Collier, R. The ethics of reusing single-use devices. CMAJ 2011;183:1245.CrossRefGoogle ScholarPubMed
Lee, RC, Berzins, S, Alfieri, N. Single-use device reuse risks. Can J Infect Control 2007;22:142146.Google ScholarPubMed
Fast, O, Fast, C, Fast, D, Veltjens, S, Salami, Z, White, MC. Limited sterile processing capabilities for safe surgery in low-income and middle-income countries: experience in the Republic of Congo, Madagascar, and Benin. BMJ Glob Health 2017;2 suppl 4:e000428.CrossRefGoogle Scholar