Miniature Signals and Miniature Counters: Accuracy Assurance Via Microprocessors and Multiparameter Control Techniques

  • L A Currie (a1), R W Gerlach (a1), G A Klouda (a1), F C Ruegg (a1) and G B Tompkins (a1)...

Abstract

When 14C signals approach background levels, the validity of assumptions concerning Poisson counting statistics and measurement system stability becomes crucial in interpreting the resultant low-level counting observations. This has been demonstrated in our previous work on detection limits for non-Poisson error and it is critical in our current studies of carbonaceous pollutants, where the 14C signal from just 5 mg C is comparable to that of the background for our miniature gas proportional counters. To assure data quality, our multi-detector system is designed for the on-line monitoring of critical parameters that reflect both the (statistical) nature of the non-Poisson errors and the underlying (physical) causes. It sends >60 bits of information/pulse to a microprocessor which automatically generates, for each counting period, two-dimensional spectra and multiparameter correlation and control charts. To evaluate the validity of long-term counting of 1–10 mg C we use robust (statistical) estimators, optimal counting interval subdivision, and time series analysis of the individual pulses. New opportunities for selective sampling and chemical fractionation which come with the small sample measurement capability have led us to give special attention also to higher control levels, involving e g, isotonic heterogeneity and representative standard materials.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      Miniature Signals and Miniature Counters: Accuracy Assurance Via Microprocessors and Multiparameter Control Techniques
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      Miniature Signals and Miniature Counters: Accuracy Assurance Via Microprocessors and Multiparameter Control Techniques
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      Miniature Signals and Miniature Counters: Accuracy Assurance Via Microprocessors and Multiparameter Control Techniques
      Available formats
      ×

Copyright

References

Hide All
Cooper, JA, Currie, LA, and Klouda, GA, 1981, Assessment of Contemporary carbon combustion source contributions to urban air particulate levels using C-14 measurements: Environmental Sci Technol, v 15, p 1045.
Cooper, JA and Malek, D, eds, 1981, Conference on residential solid fuels, environmental impacts and solutions: Oregon Graduate Center, p 365385.
Cox, DR and Lewis, PAW, 1966, The statistical analysis of series of events: New York, Wiley & Sons, Chap 6.
Currie, LA, 1973, The limit of precision in nuclear and analytical chemistry: Nuclear Instruments Methods, v 100, p 387395.
Currie, LA, 1978, Bias Detection, in : New York, John Wiley and Sons, p 151.
Currie, LA, Klouda, GA, Continetti, RE, Kaplan, IR, Wong, WW, Dzubay, TG, and Stevens, RK, 1983, On the origin of carbonaceous particles in American Cities: Results of radiocarbon dating and chemical characterization, in Stuiver, M and Kra, RS, eds, Internatl 14C conf; Radiocarbon, v 25.
Currie, LA, Noakes, J, and Breiter, D, 1979, Measurement of small radiocarbon samples: Power of alternative methods for tracing atmospheric hydrocarbons, in Berger, R and Suess, HE, eds, Radiocarbon dating, Internatl 14C conf, 9th, Proc: Berkeley/Los Angeles, Univ California Press, p 158175.
Kafadar, K, Rice, J, and Spiegelman, C, 1983, One-sided trimming in small samples with asymmetric contamination: Commun in statistics, theory and methods, v 12, no. 4, p 477496.
Polach, HA, Soini, E, Kojola, H, Robertson, S, and Kaihola, L, 1982, Radiocarbon dating of milligram-size samples using gas proportional counters: an evaluation of precision and of design parameters, in Australian conf on archaeometry, 1st, Proc: Sydney, Australian Museum.
Sayre, EV, Harbottle, G, Stoenner, RW, Otlet, RL, and Evans, GB, 1981, The use of the small gas proportional counters for the carbon-14 measurement of very small samples, in : IAEA, Vienna, in press.

Miniature Signals and Miniature Counters: Accuracy Assurance Via Microprocessors and Multiparameter Control Techniques

  • L A Currie (a1), R W Gerlach (a1), G A Klouda (a1), F C Ruegg (a1) and G B Tompkins (a1)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed