The Keck Carbon Cycle AMS Laboratory, University of California, Irvine: Status Report

  • Robert K Beverly (a1), Will Beaumont (a1), Denis Tauz (a1), Kaelyn M Ormsby (a1), Karl F von Reden (a2), Guaciara M Santos (a1) and John R Southon (a1)...

Abstract

We present a status report of the accelerator mass spectrometry (AMS) facility at the University of California, Irvine, USA. Recent spectrometer upgrades and repairs are discussed. Modifications to preparation laboratory procedures designed to improve sample throughput efficiency while maintaining precision of 2–3‰ for 1-mg samples (Santos et al. 2007c) are presented.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      The Keck Carbon Cycle AMS Laboratory, University of California, Irvine: Status Report
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      The Keck Carbon Cycle AMS Laboratory, University of California, Irvine: Status Report
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      The Keck Carbon Cycle AMS Laboratory, University of California, Irvine: Status Report
      Available formats
      ×

Copyright

Corresponding author

Corresponding author. Email: rbeverly@uci.edu

References

Hide All
Bottinga, Y. 1969. Calculated fractionation factors for carbon and hydrogen isotope exchange in the system calcite-carbon dioxide-graphite-methane-hydrogen-water vapor. Geochimica et Cosmochimica Acta 33(1):4964.
Goslar, T, Czernik, J, Goslar, E. 2004. Low-energy 14C AMS in Poznań radiocarbon laboratory, Poland. Nuclear Instruments and Methods in Physics Research B 223–224:511.
Santos, GM, Southon, JR, Druffel-Rodriguez, KC, Griffin, S, Mazon, M. 2004. Magnesium perchlorate as an alternative water trap in AMS graphite sample preparation: a report on sample preparation at KCCAMS at the University of California, Irvine. Radiocarbon 46(1):165–73.
Santos, GM, Southon, JR, Griffin, S, Beaupre, SR, Druffel, ERM. 2007a. Ultra small-mass AMS 14C sample preparation and analyses at KCCAMS/UCI Facility. Nuclear Instruments and Methods in Physics Research B 259(1):293302.
Santos, GM, Mazon, M, Southon, JR, Rifai, S, Moore, R. 2007b. Evaluation of iron and cobalt powders as catalysts for 14C-AMS target preparation. Nuclear Instruments and Methods in Physics Research B 259(1):308–15.
Santos, GM, Moore, RB, Southon, JR, Griffin, S, Hinger, E, Zhang, D. 2007c. AMS 14C sample preparation at the KCCAMS/UCI Facility: status report and performance of small samples. Radiocarbon 49(2):255–69.
Santos, GM, Southon, JR, Drenzek, NJ, Ziolkowski, LA, Druffel, E, Xu, X, Zhang, D, Trumbore, S, Eglinton, TI, Hughen, KA. 2010. Blank assessment for ultra-small radiocarbon samples: chemical extraction and separation versus AMS. Radiocarbon 52(2–3):1322–35.
Southon, J, Santos, GM, Druffel-Rodriguez, K, Druffel, E, Trumbore, S, Xu, X, Griffin, S, Ali, S, Mazon, M. 2004. The Keck Carbon Cycle AMS laboratory, University of California, Irvine: initial operation and a background surprise. Radiocarbon 46(1):41–9.
Southon, JR, Santos, GM. 2004. Ion source development at KCCAMS, University of California, Irvine. Radiocarbon 46(1):33–9.
Southon, J, Santos, GM. 2007. Life with MC-SNICS. Part II: recent ion source development at the Keck Carbon Cycle AMS Facility. Nuclear Instruments and Methods in Physics Research B 259(1):8893.
Southon, J, Santos, G, Han, B. 2007. Cs feed tests and emittance measurements on a modified MC-SNICS ion source for radiocarbon AMS. Radiocarbon 49(2):301–5.
Stuiver, M, Polach, HA. 1977. Discussion: reporting of 14C data. Radiocarbon 19(3):355–63.

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed