Hostname: page-component-78dcdb465f-xl52z Total loading time: 0.324 Render date: 2021-04-19T23:33:28.918Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": false, "newCiteModal": false, "newCitedByModal": true }

Article contents

Application of the Triple-Photomultiplier Liquid Spectrometer Hidex 300 Sl in Radiocarbon Dating

Published online by Cambridge University Press:  18 July 2016

Marek Krapiec
Affiliation:
AGH University of Science and Technology, Faculty of Geology, Geophysics and Environmental Protection, Al. Mickiewicza 30, 30-059 Kraków, Poland. Also: Laboratory of Absolute Dating, Cianowice 225, 32-043 Skala, Poland.
Adam Walanus
Affiliation:
AGH University of Science and Technology, Faculty of Geology, Geophysics and Environmental Protection, Al. Mickiewicza 30, 30-059 Kraków, Poland.
Corresponding
E-mail address:
Rights & Permissions[Opens in a new window]

Abstract

The Hidex 300 SL is a liquid scintillation analyzer with an automatic sample changer and a triple-photomultiplier tube detection assembly that registers triple- as well as double-coincidence spectra. In the triple mode, the background in the 14C window is 13.7 cpm (14C standard 30.8 cpm; =154.3 cpm/5.01), so the factor of merit equals 8.7. The triple-to-double coincidence ratio (TDCR) allows for determining the 14C counting efficiency, the quench level, and quench correction. However, in the case of very low-activity samples, which is the case even for modern 14C samples, the TDCR is not the best method for the correction of benzene impurities. We propose using the position (channel) of the right slope of the sample (14C) logarithmic pulse-height spectrum. In the case of near-background samples, the cosmic muon peak can be used instead. The Monte Carlo modeling of spectra gave the 14C level below which the muon peak is a better quench correction parameter than the position of the 14C spectrum. The spectrometer, with the proposed quench correction method, was tested with wood samples dated dendrochronologically. For 21 samples, there is no systematic bias observed, and the standard deviation of the age differences scaled by the Poisson errors is 1.24 ± 0.15, which means that the counting statistics account for 80% of the total variability (including sample preparation).

Type
Articles
Copyright
Copyright © 2011 The Arizona Board of Regents on behalf of the University of Arizona 

References

Broda, R. 2003. A review of the triple-to-double coincidence ratio (TDCR) method for standardizing radionuclides. Applied Radiation and Isotopes 58(5):585–94.CrossRefGoogle ScholarPubMed
Krapiec, M. 1992. Skale dendrochronologiczne póznego holocenu poludniowej i centralnej Polski. Kwartalnik AGH – Geologia 18(3):37119.Google Scholar
Krapiec, M. 2001. Holocene dendrochronological standards for subfossil oaks from the area of Southern Poland. Studia Quaternaria 18:4763.Google Scholar
McCormac, FG. 1992. Liquid scintillation counter characterization, optimization and benzene purity correction. Radiocarbon 34(1):3745.CrossRefGoogle Scholar
Robert, CP, Casella, G. 2004. Monte Carlo Statistical Methods. 2nd edition New York: Springer-Verlag.CrossRefGoogle Scholar
Simpson, BRS, Meyer, BR. 1994. Direct activity measurement of pure beta-emitting radionuclides by the TDCR efficiency calculation technique. Nuclear Instruments and Methods in Physics Research A 339(1–2):1420.CrossRefGoogle Scholar

Full text views

Full text views reflects PDF downloads, PDFs sent to Google Drive, Dropbox and Kindle and HTML full text views.

Total number of HTML views: 0
Total number of PDF views: 148 *
View data table for this chart

* Views captured on Cambridge Core between September 2016 - 19th April 2021. This data will be updated every 24 hours.

You have Access

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Application of the Triple-Photomultiplier Liquid Spectrometer Hidex 300 Sl in Radiocarbon Dating
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Application of the Triple-Photomultiplier Liquid Spectrometer Hidex 300 Sl in Radiocarbon Dating
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Application of the Triple-Photomultiplier Liquid Spectrometer Hidex 300 Sl in Radiocarbon Dating
Available formats
×
×

Reply to: Submit a response


Your details


Conflicting interests

Do you have any conflicting interests? *