Skip to main content Accessibility help
×
Home

Adaptive Wavelength Calibration Algorithm for LAMOST

  • H. Q. Qin (a1), J. Zhu (a1), Z. Q. Zhu (a1), Z. F. Ye (a1) and A. L. Luo (a2)...

Abstract

An adaptive algorithm is presented for the wavelength calibration of the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST). The new algorithm can identify emission lines of calibration lamp without manual interaction and then fit relationship between the pixel positions and the wavelengths by utilizing a polynomial function. In this study, experiments are performed both on the actual data observed by LAMOST and the simulated data to analyze the accuracy and the robustness.The experimental results show that the proposed automatic algorithm can perform the lines identification exactly and acquire the wavelength solution accurately. Thus, an applicable approach is provided for the wavelength calibration of LAMOST.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      Adaptive Wavelength Calibration Algorithm for LAMOST
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      Adaptive Wavelength Calibration Algorithm for LAMOST
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      Adaptive Wavelength Calibration Algorithm for LAMOST
      Available formats
      ×

Copyright

Corresponding author

CCorresponding author. Email: yezf@ustc.edu.cn

References

Hide All
Bai, L., Liao, N. F., Li, Z. J. & Yang, W. P., 2004, ChOpL, 2, 174
Burles, S. & Schlegel, D., 2007, SDSS Data Reduction Software, v5.3.12, http://das.sdss.org/software
Cui, X. Q., 2009, AAS Meeting, 213, 226.01
Lo, E. & Fountain, A. W., 2006, SPIE, 6233, 62330
Qin, H. Q., Ye, Z. F. & Luo, A. L., 2009, PASP, 121, 408
Sanchez, S. F., 2006, AN, 327, 850
Thompson, R. I., Bechtold, J., Black, J. H. & Martins, C. J. A. P., 2009, NA, 14, 379
van Geffen, J. H. G. M. & van Oss, R. F., 2003, ApOpt, 42, 2739

Keywords

Adaptive Wavelength Calibration Algorithm for LAMOST

  • H. Q. Qin (a1), J. Zhu (a1), Z. Q. Zhu (a1), Z. F. Ye (a1) and A. L. Luo (a2)...

Metrics