        To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

        Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

        Find out more about the Kindle Personal Document Service.

        Determination of analytical precision in calculating total energy expenditure using the doubly labelled water method in humans
        Available formats
        ×

        Send article to Dropbox

        To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

        Determination of analytical precision in calculating total energy expenditure using the doubly labelled water method in humans
        Available formats
        ×

        Send article to Google Drive

        To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

        Determination of analytical precision in calculating total energy expenditure using the doubly labelled water method in humans
        Available formats
        ×
Export citation

Doubly labelled water (DLW) is the gold standard method for estimation of free-living energy expenditure in humans(1).  Overall precision is an important factor to consider when designing a study, as poor precision in total energy expenditure (TEE) will increase the sample size required.  The precision or analytical variation of modelled TEE is variable and dependent on the laboratory, instrumentation used and specific methodology used.  In order to calculate the precision of our methodology, we assessed the reproducibility of modelled TEE estimation over ten consecutive weeks.  Additionally, jack-knife resampling was used to assess bias within an individual estimate of TEE.

Two female participants (mean (SD): age, 40 (4) years: height, 1.66 (0.04) m: weight, 77.6 (9.1) kg) were dosed with 150 mg/kg body weight H218O (Taiyo Nippon Sanso, Tokyo, Japan) and 80 mg/kg body weight 2H2O (Cambridge Isotope Laboratories, Massachusetts, USA).  The protocol was approved by the East of England - Cambridge Central Research Ethics Committee, Cambridge, UK.   Eleven urine samples were collected, comprising of a baseline urine sample followed by ten consecutive days post-dosing, avoiding the first void of the day. To minimise freeze-thaw cycles, each urine sample was aliquoted into ten 7 ml glass bijou bottles and stored at −20 °C until analysis.  Analysis of H218O and 2H2O was conducted weekly using a continuous-flow isotope ratio mass spectrometer (AP2003, Analytical Precision Ltd., Northwich, Cheshire, UK) and a dual-inlet isotope ratio mass spectrometer (IsoPrime, GV Instruments Ltd., Wythenshawe, Manchester, UK) respectively.  Energy expenditure was modelled according to Schoeller(2) and expressed in kilojoules.  Precision was calculated as the coefficient of variation.

Average daily TEE for repeat measurements was 8643 (52) kJ and 8683 (52) kJ (mean (SE)) for participant Y & W respectively.  Both had total analytical precisions of 1.20 %, with separate precisions for isotope elimination rates and dilution spaces reported in Table 1.  Jack-knife resampling confirmed a standard error of the TEE estimate of 63  and 127 kJ and a small mean bias of 12 and −15 kJ.

Table 1. Isotope elimination rates and dilution spaces for the two participants.

Preliminary data for four repeat measurements. Values are means with  %CV.

ko, oxygen elimination rate; kh, hydrogen elimination rate; No, oxygen dilution space; Nh, hydrogen dilution space; TEE, total energy expenditure.

In conclusion, the analytical precision for our laboratory when using the doubly labelled water method to calculate TEE is well within the published limits of 3-6 %(3, 4).

1.Schoeller, DA & van Santen, E. (1982) J Appl Physiol Respir Environ Exerc Physiol 53(4), 955–9.
2.Schoeller, DA, Ravussin, E, Schutz, Y et al. (1986) Am J Physiol 250(5 Pt 2), R823–30.
3.Schoeller, DA, Taylor, PB & Shay, K (1995) Obesity Research 3(1), 1520.
4.Cole, TJ & Coward, WA (1992) Am J Physiol 263(26), E965E973.