The Rapid Prehospital Estimation of Blood Glucose Using Chemstrip bG

Published online by Cambridge University Press:  28 June 2012

Paul T. Hogya*
Affiliation:
University of Pittsburgh Affiliated Residency in Emergency Medicine
Donald M. Yealy
Affiliation:
University of Pittsburgh Affiliated Residency in Emergency Medicine
Paul M. Paris
Affiliation:
Division of Emergency Medicine, Department of Medicine, University of Pittsburgh School of Medicine, Center for Emergency Medicine of Western Pennsylvania
Ronald D. Stewart
Affiliation:
Department of Surgery and Anesthesia, University of Toronto
*
Presented at the Scientific Assembly of the National Association of EMS Physicians, San Francisco, CA, June 1989.

Abstract

The accuracy of the glucose reagent strip, Chemstrip bG, for the determination of the presence of hypoglycemia, euglycemia, or hyperglycemia was assessed in the prehospital setting when used by paramedics treating patients with an altered level of consciousness. Venous blood specimens were obtained from each of sixty-two patients. Serum glucose levels of the sample were determined by paramedics in the field using the Chemstrip bG and within three hours after sample acquisition by standard laboratory techniques. The sensitivity and specificity of detecting true hypoglycemia (serum glucose<61 mg/dl) using the field reagent strips were 100% and 83.3% respectively. The corresponding 95% lower limits of confidence (LLC) were 81.3% and 83 .3%. The sensitivity and specificity of field detection of the absence of hypoglycemia (serum glucose ≥ 61 mg/dl) were 86.6 % (LLC=80.9%) and 100% (LLC=81.3%) respectively. The accuracy of the reagent strips is specific but not sensitive for the determination of the presence of hyperglycemia (serum glucose > 179 mg/dl). Thus, the Chemstrip bG is an accurate means for the rapid identification of the presence or absence of hypoglycemia in the field setting by paramedics.

Type
Original Research
Copyright
Copyright © World Association for Disaster and Emergency Medicine 1989

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Henry, GL: Coma and altered states of consciousness. in Emergency Medicine: A Comprehensive Study Guide, Tintanalli, JE, Rothstein, RJ, Krome, RL (eds): New York, McGraw-Hill Co., 1985; p. 127.Google Scholar
2. Adler, PM: Serum glucose changes after administration of 50% dextrose solution: pre-and in-hospital calculations. Am J Emerg Med 1986; 4:504506.CrossRefGoogle ScholarPubMed
3. Goldfarb, S, Cox, M, Singer, I, et al: Acute hyperkalemia induced by hyperglycemia: Hormonal mechanisms. Ann Intern Med 1976; 84:426432.CrossRefGoogle ScholarPubMed
4. Rehcrona, S: Brain acidosis. Ann Emerg Med 1985; 14:770776.CrossRefGoogle Scholar
5. Hanley, JA, Lippman-Hand, A: If nothing goes wrong, is everything alright? Interpreting zero numerators. JAMA 1983; 249:17431745.CrossRefGoogle Scholar
6. Rennie, IDB, Keen, H, Southon, H: A rapid enzyme strip method for estimating blood sugar. Lancet 1964; 884887.CrossRefGoogle ScholarPubMed
7. Marks, V, Dawson, B: Rapid stick method for determining blood glucose concentration. Br Med J 1965; 2:293295.CrossRefGoogle Scholar
8. Harvey, DR, Cooper, LV, Fancourt, RF, et al: The use of Dextrostix reflectance meters in the diagnosis of neonatal hypoglycemia. J Perinat Med 1976; 4:106109.CrossRefGoogle ScholarPubMed
9. Dorchy, H, Lock, H: Evaluation of a Dextrostix scale for hypoglycemia. Helv Paediat Acta 1973; 28:565568.Google Scholar
10. Keane, NA, Clemens, RS Jr, Kirk, KA: The accuracy of various methods for home glucose monitoring. Abstract. National Meeting of the American Diabetes Association, June 1980, Washington, D.C.Google Scholar
11. Canfield, ME, Kemp, SF, Hoft, C: Assessment of a new blood glucose strip: comparison of Visidex, Visidex II, and Chemstrip bG with glucose analyzer determination of blood glucose. Diabetes Care 1985; 11:293295.Google Scholar
12. Maisels, MJ, Lee, CA: Chemstrip glucose test strips: Correlation with true glucose values less than 80 mg/dl. Crit Care Med 1983; 11:293295.CrossRefGoogle ScholarPubMed
13. Clarke, WL, Cox, D, Carter, WL, et al: Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 1987; 10:622628.CrossRefGoogle ScholarPubMed
14. Silverstein, JH, Rosenbloom, AL, Clarke, DW, et al: Accuracy of two systems for blood glucose monitoring without a meter (Chem-strip/Visdex). Diabetes Care 1983; 6:533535.CrossRefGoogle Scholar