Skip to main content Accessibility help
×
Home

Secondary excitation process for quantitative confocal 3D-XRF analysis

  • Kouichi Tsuji (a1), Atsushi Tabe (a1), Peter Wobrauscheck (a2) and Christina Streli (a2)

Abstract

X-ray fluorescence (XRF) is a well-established method for quantitative elemental analysis. For accurate quantification, secondary excitation has to be taken into account. In this paper, the secondary excitation process was discussed for analysis by confocal micro-XRF. Experimental depth profiles were shown for a layered sample of Co and Cu. An additional peak was observed in the depth profile of Co, and it was explained by secondary excitation process. Additionally, a Mosaic model was proposed for quantification of confocal micro- XRF analysis.

Copyright

Corresponding author

a) Author to whom correspondence should be addressed. Electronic mail: tsuji@a-chem.eng.osaka-cu.ac.jp

References

Hide All
Ding, X., Gao, N., and Havrilla, G. (2000). “Monolithic polycapillary x-ray optics engineered to meet a wide range of applications,” Proceedings of SPIE. 4144, 174182.
Gibson, W. M. and Kumakhov, M. A. (1993). “Application of X-ray and neutron optics,” Proc. SPIE. 1736, 172189.
Hirano, S., Akioka, K., Doi, T., Arai, M., and Tsuji, K. (2014). “Elemental depth imaging of solutions for monitoring corrosion process of steel sheet by confocal micro-XRF,” X-Ray Spectrom. 43, 216220.
Kanngiesser, B., Malzer, W., and Reiche, I. (2003). “A new 3D micro X-ray fluorescence analysis set-up – First archaeometric applications,” Nucl. Instrum. Methods Phys. Res., Sect. B. 211, 259264.
Mantouvalou, I., Malzer, W., and Kanngiesser, B. (2012). “Quantification for 3D micro X-ray fluorescence,” Spectrochim. Acta Part B 77, 918.
Nakano, K. and Tsuji, K. (2009). “Nondestructive elemental depth profiling of Japanese lacquerware ‘Tamamushi-nuri’ by confocal 3D X-ray analysis in comparison with micro GE-XRF,” X-Ray Spectrom. 38, 446450.
Nakano, K. and Tsuji, K. (2010). “Development of laboratory confocal 3D-XRF spectrometer and nondestructive depth profiling,” J. Anal. At. Spectrom. 25, 562569.
Nakano, K., Nishi, C., Otsuki, K., Nishiwaki, Y., and Tsuji, K. (2011). “Depth elemental imaging of forensic samples by confocal micro-XRF method,” Anal. Chem. 83, 34773483.
Nakazawa, T. and Tsuji, K. (2013a). “Development of a high resolution confocal micro-XRF instrument equipped with a vacuum chamber,” X-Ray Spectrom. 42, 374379.
Nakazawa, T. and Tsuji, K. (2013). “Depth-selective elemental imaging of microSD card by confocal micro-XRF analysis,” X-Ray Spectrom. 42, 123127.
Schoonjans, T., Silversmit, G., Vekemans, B., Schmitz, S., Burghammer, M., Riekel, C., Brenker, F. E., and Vincze, L. (2012). “Fundamental parameter based quantification algorithm for confocal nano-X-ray fluorescence analysis,” Spectrochim. Acta Part B. 67, 3242.
Smolek, S., Pemmer, B., Fölser, M., Streli, C., and Wobrauschek, P. (2012). “Confocal micro-x-ray fluorescence spectrometer for light element analysis,” Rev. Sci. Instrum. 83, 083703; doi: 10.1063/1.4744934
Smolek, S., Nakazawa, T., Tabe, A., Nakano, K., Tsuji, K., Streli, C., and Wobrauschek, P. (2013). “Comparison of two confocal micro-XRF spectrometers with different design aspects,” X-ray Spectrom. 43, 93101.
Sokaras, D. and Karydas, A. G. (2009). “Secondary fluorescenec enhancement in confocal X-ray microscopy analysis,” Anal. Chem. 81, 49464954.
Tsuji, K. and Nakano, K. (2007). “Development of confocal 3D micro XRF spectrometer with Cr-Mo dual excitation,” X-Ray Spectrom. 36, 145149.
Tsuji, K. and Nakano, K. (2011). “Development of a new confocal 3D-XRF instrument with an X-ray tube,” J. Anal. At. Spectrom. 26, 305309.
Tsuji, K., Nakano, K., and Ding, X. (2007). “Development of confocal micro X-ray fluorescence instrument using two X-ray beams,” Spectrochim. Acta Part B. 62, 549553.
Tsuji, K., Yonehara, T., and Nakano, K. (2008). “Application of confocal 3D micro-XRF for solid/liquid interface analysis,” Anal. Sci. 24, 99103.

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed