Hostname: page-component-684bc48f8b-kbzls Total loading time: 7.091 Render date: 2021-04-11T11:13:42.273Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": false, "newCiteModal": false, "newCitedByModal": true }

Dispersive double bent crystal monochromators Si(111) + Si(311) and Si(111) + Si(400) with a strongly asymmetric diffraction geometry of the analyzer for powder diffractometry

Published online by Cambridge University Press:  19 March 2019

P. Mikula
Affiliation:
Neutron Physics Department, Nuclear Physics Institute, ASCR v.v.i, Rez, Czech Republic
M. Vrana
Affiliation:
Neutron Physics Department, Nuclear Physics Institute, ASCR v.v.i, Rez, Czech Republic
J. Saroun
Affiliation:
Neutron Physics Department, Nuclear Physics Institute, ASCR v.v.i, Rez, Czech Republic
J. Stammers
Affiliation:
Neutron Physics Department, Nuclear Physics Institute, ASCR v.v.i, Rez, Czech Republic
V. Em
Affiliation:
National Research Centre “Kurchatov Institute”, Moscow, Russian Federation
Corresponding
E-mail address:

Abstract

In this paper, some results of neutron diffraction properties of the dispersive double-crystal Si(111) + Si(311) and Si(111) + Si(400) monochromator settings containing two bent perfect crystals but with the second one – analyzer in the strongly asymmetric diffraction geometry, are presented. For the sake of possible applications, both double crystal settings were tested in the orientation of the second crystal for the output beam compression geometry. Powder diffraction test was carried out on a α-Fe(211) pin of the diameter of 2 mm. Contrary to the Si(111) + Si(400) setting, an excellent resolution represented by full width at half maximum in the (Δd/d)-scale was obtained for the Si(111) + Si(311) double crystal monochromator in the parallel as well as in the antiparallel diffraction geometry.

Type
Technical Articles
Copyright
Copyright © International Centre for Diffraction Data 2019 

Access options

Get access to the full version of this content by using one of the access options below.

References

Hempel, A., Eichhorn, F., Reichel, P., and Boede, W. (1996). “A neutron double-crystal diffractometer with a position sensitive detector for small-angle scattering studies,” Nucl. Instrum. Methods in Phys. Res. A 381, 466471.CrossRefGoogle Scholar
Kulda, J. (1984). “A novel approach to dynamical neutron diffraction by a deformed crystal,” Acta Crystallogr. Section A 40, 120126.CrossRefGoogle Scholar
Kulda, J., and Mikula, P. (1983). “A medium resolution double crystal diffractometer for SANS studies,” J. Appl. Cryst. 16, 498504.CrossRefGoogle Scholar
Mikula, P., and Vrána, M. (2015). “New type of versatile diffractometer with a double-crystal (DC) monochromator system”, In Proc. of the Int. Conf. EPDIC 14, June 15–18, 2014, Aarhus, Denmark; Powder Diffraction, 30, Suppl. S1, S41–S46.Google Scholar
Mikula, P., Kulda, J., Vrána, M., and Chalupa, B. (1984). “A proposal of a highly efficient double crystal monochromator for thermal neutrons,” J. Appl. Cryst. 17, 189195.CrossRefGoogle Scholar
Mikula, P., Lukáš, P., and Eichhorn, F. (1988). “New version of a medium resolution double-crystal diffractometer for the study of a small angle neutron scattering (SANS),” J. Appl. Crystallogr. 21, 3337.CrossRefGoogle Scholar
Mikula, P., Vrána, M., Šaroun, J., Pilch, J., Seong, B. S., Woo, W., and Em, V. (2014). “Neutron diffraction studies of double crystal (+n,-m) setting containing a fully asymmetric diffraction geometry (FAD) of a bent perfect crystal (BPC) with the output beam expansion (OBE)”, J. Appl. Cryst. 47, Part 2, 599605.CrossRefGoogle Scholar
Mikula, P., Vrána, M., and Korytár, D. (2015). “Observation of edge refraction on a conventional neutron diffractometer employing dispersive double-crystal monochromator,” Physics Procedia. 69, 320326.CrossRefGoogle Scholar
Šaroun, J., and Kulda, J. (2009). “Monte Carlo simulation package RESTRAX 5.2.0 and SIMRES 6.0.6,” June 2009, Available at http://neutron.ujf.cas.cz/restrax/index.php?chap=3/.Google Scholar
Šaroun, J., Lukáš, P., Mikula, P., and Alefeld, B. (1994). “Optimization of a double-bent crystal diffractometer for small-angle neutron scattering experiments,” J. Appl. Crystallogr. 27, 8088.CrossRefGoogle Scholar

Full text views

Full text views reflects PDF downloads, PDFs sent to Google Drive, Dropbox and Kindle and HTML full text views.

Total number of HTML views: 10
Total number of PDF views: 59 *
View data table for this chart

* Views captured on Cambridge Core between 19th March 2019 - 11th April 2021. This data will be updated every 24 hours.

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Dispersive double bent crystal monochromators Si(111) + Si(311) and Si(111) + Si(400) with a strongly asymmetric diffraction geometry of the analyzer for powder diffractometry
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Dispersive double bent crystal monochromators Si(111) + Si(311) and Si(111) + Si(400) with a strongly asymmetric diffraction geometry of the analyzer for powder diffractometry
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Dispersive double bent crystal monochromators Si(111) + Si(311) and Si(111) + Si(400) with a strongly asymmetric diffraction geometry of the analyzer for powder diffractometry
Available formats
×
×

Reply to: Submit a response


Your details


Conflicting interests

Do you have any conflicting interests? *