Skip to main content Accessibility help
×
Home

X-Ray Nanoplasma Instruments and Tools

  • Scott Bloom (a1), Harry Rieger (a1) and Jim Alwan (a1)

Abstract

Soft x-rays have wavelengths in the range of 1–15 nm and therefore the diffraction limited spot size of focused x-rays can be as small as 1.22 × the radiation wavelength, or less than 20 nm spot size. Using our pulsed x-ray source and focusing a small collected solid angle of this x-ray radiation to a sample provides enough power to form a very hot plasma that emits a range of radiation from UV through IR that can be collected and analyzed on a conventional optical spectrometer. In addition to diagnostic capabilities the instrument can be also used as a tool to form structures at nanometer scale resolution. Since the plasma is formed by ablating the target material with x-rays the target can be patterned or nanomachined using the plasma itself. It should be possible to pattern nanoscale devices by rastering the material under the nanoplasma. Finally in analogy to plasma assisted CVD processes, organometallic vapors could introduced into the sample chamber such that the nanoplasma locally plates out specific species of metals of other materials on the target at nanoscale sizes for forming devices, circuits, wires, etc. This paper presents a design for a nanoplasma instrument, predicted performance parameters will be presented, and development issues identified and discussed.

Copyright

References

Hide All
1. Ding, Y., Micheletto, R., Hanada, H., Nagamura, T., Okazaki, S., Rev. Sci. Instrum. 73 (2002) 3227.
2. Kossakovski, D., Beauchamp, J.L., Anal. Chem. 72 (2000) 4731.
3. Dutoit, B., Zeisel, D., Deckert, V., Zenobi, R., J. Phys. Chem. B 101 (1997) 6955.
4. “Soft X-ray Laser Produces 3 W Of Output At 1 nm” Photonics Online 4/1/99
5. “Tinier Chips, Then Life's Tiniest Secrets” Los Angeles Times 4/19/99
6. Turcu, E., Rieger, H., Forber, R., Campeau, S., Powers, M., French, G., Grygier, R., Foster, R., Mitchell, P., and Gaeta, C., “High power x-ray source for next generation lithography”, EUV, X-Ray and Neutron Optics and Sources, SPIE Conf. Proc., SPIE 3767, 1999
7. Turcu, ICE., Rieger, H., Vladimirsky, Y., Grygier, R., Powers, M., Naungayan, J., Campeau, S., French, G., Forber, R., and Foster, R., “Microfocus Soft X-Ray Source Generated by a Compact High Power Laser plasma”, Advances in Laboratory X-ray Sources and Optics, SPIE Vol. 4141 (2000)
8. Rieger, H., JMAR Technologies, Inc. “X-ray Vision - The Tabletop Laser System Yields a Plasma X-ray Source” OE Magazine publication of SPIE-The International Society for Optical Engineers. March 2001.
9. Rieger, H. and Campeau, Serge300 W Diode Pumped Nd:YAG Laser System for Soft X-Ray Generation”, TOPS 2001 Advanced Solid-State Lasers, OSA
10. Gaeta, C. J., Rieger, H., Turcu, I.C.E., Forber, R.A., Campeau, S.M., Cassidy, K.L., Powers, M.F., Maldonado*, J.R., French, G., Naungayan, J., Kelsy, C., Hark, P., Morris, J. H., Foster, R. M., Smith, H.I., and Lim, M.H. “High Power Compact LaserPlasma Source for X-Ray Lithography”, Japanese J of Appl. Phys. June 2002.

X-Ray Nanoplasma Instruments and Tools

  • Scott Bloom (a1), Harry Rieger (a1) and Jim Alwan (a1)

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed