Hostname: page-component-8448b6f56d-jr42d Total loading time: 0 Render date: 2024-04-23T21:52:59.341Z Has data issue: false hasContentIssue false

Synchrotron X-ray Absorption Studies of Atomic-Level Alloying in Immiscible Mixtures

Published online by Cambridge University Press:  10 February 2011

J.-H. He
Affiliation:
Center for Advanced Microstructures and Devices (CAMD) and Department of Mechanical Engineering, Louisiana State University, Baton Rouge, LA 70803
P. J. Schilling
Affiliation:
Center for Advanced Microstructures and Devices (CAMD) and Department of Mechanical Engineering, Louisiana State University, Baton Rouge, LA 70803
E. Ma
Affiliation:
Center for Advanced Microstructures and Devices (CAMD) and Department of Mechanical Engineering, Louisiana State University, Baton Rouge, LA 70803
Get access

Abstract

An X-ray absorption beamline has been developed recently at the electron storage ring of the LSU Center for Advanced Microstructures and Devices. Using Extended X-ray Absorption Fine Structure (EXAFS) and X-ray Absorption Near Edge Structure (XANES), we have studied the local atomic environments in immiscible mixtures processed by high-energy ball milling, a mechanical alloying technique involving heavy deformation. By examining the local coordination and bond distances, it is concluded that atomic-level alloying can indeed be induced between Cu and Fe through milling at room temperature, forming substitutional fcc and bcc solid solutions. In addition to single-phase regions, a two-phase region consisting of fcc/bcc solutions has been found after milling at both room temperature and liquid nitrogen temperature. In contrast to the Cu-Fe system, solid solution formation is not detectable in milled Ag-Fe and Cu-Ta mixtures. This work demonstrates the power of synchrotron EXAFS/XANES experiments in monitoring nonequilibrium alloying on the atomic level. At the same time, the results provide direct experimental evidence of the capability as well as limitations of high-energy ball milling to form alloys in positive-heat-of-mixing systems.

Type
Research Article
Copyright
Copyright © Materials Research Society 1998

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1. Yavari, A. R., Desre, P. J. and Benameur, T., Phys. Rev. Lett. 68, 2235 (1992).Google Scholar
2. Eckert, J., Holzer, J. C., Krill III, C. E. and Johnson, W. L., J. Appl. Phys. 73, 2794 (1993).Google Scholar
3. Ma, E., Atzmon, M. and Pinkerton, F. E., J. Appl. Phys. 74, 955 (1993).Google Scholar
4. Drbohlav, O. and Yavari, A. R., Acta. Metall. Mater. 43,1799 (1995).Google Scholar
5. Gente, C., Oehring, M. and Bormann, R., Phys. Rev. B48, 13244 (1993).Google Scholar
6. Huang, J. Y., Wu, Y. K., He, A. Q. and Ye, H. Q., Nanostructured Materials, 4, 293 (1994); also 4, 1 (1994).Google Scholar
7. Klug, H. P. and Alexander, L. E., X-ray Diffraction Procedures, 2nd ed. (John Wiley, NY, 1974), Chap. 7, p. 531.Google Scholar
8. Kuyama, J., Inui, H., Imaoka, S., Nasu, S., Ishihara, K. and Shingu, P. H., J. J. Appl. Phys. 30, L854 (1991).Google Scholar
9. Jiang, J., Gonser, U., Gente, C. and Bormann, R., Appl. Phys. Lett. 63, 1056 (1993).Google Scholar
10. Macri, P., Rose, P., Frattini, R., Enzo, S., Principi, G., Hu, W., and Cowlam, N., J. Appl. Phys. 76, 4061 (1994).Google Scholar
11. Herr, U., Jing, J., Gonser, U. and Gleiter, H., Sol. Stat. Comm. 76, 197 (1990).Google Scholar
12. Wong, J., Nixon, W. E. and Mitchell, J. W., J. Appl. Phys. 71, 150 (1992).Google Scholar
13. Stern, E. A., Newville, M., Ravel, B., Yacoby, Y. and Haskel, D., Physica B, in press.Google Scholar
14. Schilling, P. J., He, J., Cheng, J. and Ma, E., Appl. Phys. Lett. 68, 767 (1996).Google Scholar
15. Ma, E., He, J. H. and Schilling, P. J., Phys. Rev. B 55, 5542 (1997).Google Scholar
16. Xu, J., He, J.-H. and Ma, E., Met. Mater. Trans. 28A, 1569 (1997).Google Scholar