We report the synthesis of a nanocomposite materials consisting of gallium nitride (GaN) confined in the well ordered mesoporous transparent matrix MCM-41 with the help of the metalorganic single source precursor triazido(trimethylamine)gallium using solution impregnation technique. The loading of the pores of MCM-41 with GaN was confirmed by chemical analysis, XRD, TEM, BET, NMR and optical spectroscopy (PL and PL-excitation spectroscopy). The composites exhibit a blue shift of the bandgap of GaN due to quantum confinement.

Type
Research Article
Copyright
Copyright © Materials Research Society 2000

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

[1] Nakamura, S. and Fasol, G., The Blue Laser Diode, Springer, Berlin, Heidelberg, New York, 1997.Google Scholar
[2] a) Janik, J. F. and Wells, R. L., Chem. Mater. 8, p. 2,708 (1996)Google Scholar
-b) Frank, A. C., F. Stowasser, Sussek, H., Pritzkow, H., Miskys, C. R., Ambacher, O., Giersig, M. and Fischer, R. A., J. Am. Chem. Soc. 120, p.3,512 (1998).Google Scholar
[3] Ying, J. Y., Mehnert, C. P. and Wong, M. S., Angew. Chem. Int. Ed. 38, p. 56 (1999).Google Scholar
[4] Srdanov, V. I., Alxneit, I., Stucky, G. D., Renves, C. M. and DenBaars, S. P., J. Phys. Chem. B, 102, p.3,341 (1998). J. R. Agger, M. W. Anderson, M. E. Pemble, 0. Terasaki and Y. Nozoe, J. Phys. Chem. B. 102, p. 3,345 (1998).Google Scholar
[5] Marler, B., Oberhagemann, U., Vortmann, S. and Gies, H., Microporous Mater. 6, p. 375 (1996).Google Scholar
[6] ICP data were obtained with a PU 7000 of Philips-Unicom. The samples were dissolved by sodium peroxide melt-cooking. Elemental analysis data were obtained with a Elementar VarioEL.Google Scholar
[7] Brunauer, S., Emmett, P. H. and Teller, E., J. Am. Chem. Soc. 60, p. 309 (1938). E. P. Barrett, L. G. Joyner and P. P. Halenda, J. Am. Chem. Soc. 73, p. 373 (1951). Nitrogen sorption measurements were carried out using a Quantachrome Autosorb 1 at 77 K. The samples were degassed for 12 h at 300°C in vacuum before measurement.Google Scholar
[8] Powder X-ray diffraction pattern were obtained using a D 8 advance of Bruker axs with Cu Kcx radiation.Google Scholar
[9] Transmission electron micrographs were obtained using a Hitachi H 8100 operating at 200 kV. The samples were dissolved in ethanol with ultrasonics and dispersed on a carbon-copper-grid.Google Scholar
[10] The solid state 71Ga-NMR spectra were obtained with a Bruker ASX 400 spectrometer in static mode with 122 MHz resonance frequency and hahn-echo-technique.Google Scholar
[11] Photoluminescence (PL) experimental setup: the sample was excited with 5 eV by a modulated (lock-in-technique) 30 W deuterium lamp combined with a band pass filter at room temperature. The resulting photoluminescence was collected by a quartz lens dispersed through a monochromator (Jobin-Yvon HR-640, spectral resolution 1 nm) and registered by means of a photomultiplier (Hamamatsu R 375 P). The spectra are not corrected for the spectral sensitivity of the equipment. The spectral components were weighted by he spectral slitwidth.Google Scholar
[12] Madelung, O., Semiconductor-Basic Data, Springer, Berlin, Heidelberg, New York, 1996.Google Scholar
[13] Photoluminescence excitation spectroscopy setup: Photoluminescence excitation spectroscopy setup: a modulated (lock-in technique) 150 W Xenon lamp combined with a double monochromator (Jobin Yvon DH 10, spectral resolution 8 nm) was used as excitation source. The luminescence was collected at room temperature by a quartz lens, filtered by a long pass filter (edge at 450 nm) and detected by means of a photomultiplier (Hamamatsu R 4220). The spectra were corrected by the spectral distribution of the excited light.Google Scholar
[14] Éfros, A. L. and Éfros, A. L., Sov. Phys. Semicond. 16, p. 772 (1982). Parameters of equation (1) a: particle size and me and mh effective electron and hole mass, respectively, me = 0.27 m0 , mh = 0.8 m0 (data from bulk GaN) and m0 = 9.1095. 10−31 kg being the electron rest mass.Google Scholar