Hostname: page-component-8448b6f56d-c47g7 Total loading time: 0 Render date: 2024-04-25T04:15:14.674Z Has data issue: false hasContentIssue false

Protection Layer Influence on Capacitive Micromachined Ultrasonic Transducers Performance

Published online by Cambridge University Press:  01 February 2011

Edgard Jeanne
Affiliation:
edgard.jeanne@st.com, Université de Tours, Laboratoire de Microélectronique de Puissance, Rue Pierre et Marie Curie - B.P. 7155, TOURS, 37071 TOURS CEDEX 2, France
Cyril Meynier
Affiliation:
cyril.meynier@univ-tours.fr, Université Francois Rabelais, LUSSI CNRS FRE 2448, Tours, 37000, France
Franck Teston
Affiliation:
franck.teston@univ-tours.fr, Université Francois Rabelais, LUSSI CNRS FRE 2448, Tours, 37000, France
Dominique Certon
Affiliation:
dominique.certon@univ-tours.fr, Université Francois Rabelais, LUSSI CNRS FRE 2448, Tours, 37000, France
Nicolas Felix
Affiliation:
nicolas.felix@vermon.com, Vermon SA, Tours, 37000, France
Mathieu Roy
Affiliation:
mathieu.roy@st.com, STMicroelectronics, R&D, Tours, 37071, France
Daniel Alquier
Affiliation:
daniel.alquier@univ-tours.fr, Université de Tours, Laboratoire de Microélectronique de Puissance, Tours, 37071, France
Get access

Abstract

For MEMS technology, reliability is of major concern. The implementation of a protection and passivation layer, that may easily enhance reliability of capacitive Micromachined Ultrasonic Transducers (cMUTs) must be done without degrading device performance. In this work, realization, simulation and characterization of passivated cMUT are presented. Two materials, SiNx and Parylene C, were selected with regard to their mechanical and physical properties as well as their compatibility with device processing. Particular attention was paid on layer deposition temperature to avoid a structural modification of the top aluminium electrode and, hence, a membrane bulge. The characterization results are in good agreement with the simulations. The SiN passivation layer clearly impact device performance while Parylene C effectiveness is clearly pointed out even through ageing characterizations. If SiNx layer can be used for passivation with particular precautions, Parylene is definitely an interesting material for cMUT passivation and protection.

Type
Research Article
Copyright
Copyright © Materials Research Society 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Felix, N., in Smart System Integration 2007, edited by Gessner, T., 99-105 (2007).Google Scholar
2 Belgacem, B., Yaakoubi, N., Jeanne, E., Roy, M., Jerisian, R., Alquier, D., Proc. Eurosensors XIX, WPb 28 (2005).Google Scholar
3 Ong, P. L., Wei, J., Tay, F., Iliescu, C., J. Phys.: Conference Series, 34, 764769 (2006).Google Scholar
4 Yao, T. J., Yang, X. and Tai, Y.-C., Sens. Actuators A, 98, 771–5 (2002).Google Scholar
5 Yao, T. J., Parylene for MEMS applications, Ph.D. thesis, California Institute of Technology, CA, (2002).Google Scholar
6 Karnfelt, C., Tegnander, C., IEEE Trans. Microwave Theory and Techniques, 54, 8 (2006).Google Scholar
7 Chen, J. M and Zhao, J. J., Solid-State Integ. Circuit Tech., 569571 (2006).Google Scholar
8 Certon, D., Teston, F., Patat, F., cMUT Special Issue in IEEE-UFFC, 52, 12, 21992210 (2005).Google Scholar
9 Belgacem, B., Alquier, D., Muralt, P., Baborowski, J., J. Micromech. Microeng., 14, 299304 (2004).Google Scholar
10 Cianci, E., Schina, A., Minotti, A., Foglietti, V., Sens. Actuators A, 127, 8087 (2006).Google Scholar
11 Attia, P., Hesto, P., Mat. Res. Soc. Symp. Proc., 518, 38 (1998).Google Scholar
12 Belgacem, B., PhD. Thesis, Tours, France (2004).Google Scholar
13 Modlinski, R., Microelectron. Reliab., 44, 17331738 (2004).Google Scholar