Polycapillary X-Ray Optics for Thin Film Strain and Texture Analysis

  • F. A. Hofmann (a1), W. M. Gibson (a1), S. M. Lee (a1), C. A. Macdonald (a1), J. B. Ullrich (a2) and N. GAO (a2)...

Abstract

Polycapillary optics, shaped arrays consisting of hundreds of thousands of hollow glass capillary tubes, can be used to redirect, collimate, or focus x-ray beams from conventional, laboratory-based sources. Multifiber polycapillary collimating optics were placed without system optimization into a number of diffractometer systems. Strain and texture measurements were performed. Measurements on thin films with and without the lens yielded gains of 8–100. Gains are higher in comparison with systems employing pinhole rather than one-dimensional slit collimation. The collimation also resulted in peak symmetrization, which simplified peak shape analysis.

Focused beam optics provide even larger gains. Gains of 100 have been demonstrated using polycapillary optics with spot sizes as small 20 μm. This is of particular significance for providing spatial resolution for low signal applications such as thin films. The inverse dependence of the critical angle for total external reflection on photon energy also results in suppression of high energy photons. This suppression of Bremsstrahlung can allow use of higher tube potentials to increase characteristic line emission. Background suppression from a polycapillary optic ″soller slit″ is also enhanced due to the two dimensional collimation and much smaller acceptance angle of the polycapillary optics. Polycapillary optic alignment is also faster and more convenient than the usual parafocusing geometry. The combination of background suppression, intensity gain and increased tube emission by employing polycapillary optics greatly increases the signal to noise ratio for thin film stress analysis.

Copyright

References

Hide All
1 Jentzch, F., Phys. Z. 30, p. 1268, 1929.
2 Hirsch, P. B. and Keller, J. N., Phys. Soc. (London) B64, 1951.
3 Arkadiev, V. A., Kolomitsev, A. I., Kumakhov, M. A., Ponorave, I. Yu., Khodeev, I. A., Chertov, Yu.P. and Shakparonov, I. M., Sov. Phys. Usp. 32 (3), p.271, March 1989.
4 Jackson, J. D., “Classical Electrodynamics”, 1962 by John Wiley & Sons, Inc. Sect. 7.9, pp 227.
5 MacDonald, C.A., ″Applications and Measurements of Polycapillary X-Ray Optics,″ Journal of X-Ray Science and Technology, 6, p.3247, 1996.
6 Rath, B., Youngman, R., MacDonald, C. A., ″An Automated Test System for Measuring Polycapillary X-Ray Optics,″ Review of Scientific Instrumentation, 65, p.33933398, Nov. 1994.
7 Ullrich, J. B, Kovantsev, V., MacDonald, C.A., ″Measurements of Polycapillary X-Ray Optics,″ Jour. Appl. Phys., 74 (10), Nov. 15, 1993, pp. 59335939.
8 Abreu, C. C. and MacDonald, C. A., “Beam Collimation, Focusing, Filtering and Imaging with Polycapillary X-Ray and Neutron Optics,” article, in press, Physica Medica.
9 Abreu, C. C., Kruger, D. G., MacDonald, C. A., Mistretta, C. A., Peppler, W. W., Xiao, Q. F., ″Measurements of Capillary X-Ray Optics with Potential for Use in Mammographic Imaging,″ Med. Phy. 22 (11), Pt. 1, p. 17931801, November 1995.
10 Kruger, D. G., Abreu, C. C., Hendee, E. G., Kocharian, A., Peppler, W. W., Mistretta, C. A., MacDonald, C. A., “Imaging Characteristics of X-Ray Capillary Optics in Mammography,” Medical Physics 23 (2), February, p. 187196, 1996.
11 Russell, C. H., Gibson, W. M., Gubarev, M. V., Hofmann, F. A., Joy, M. K., MacDonald, C. A., Wang, Lei, Xiao, Qi-Fan, Youngman, R., “Collector for 10–100 keV X-Rays based on polycapillary optics” in R. B. Hoover and A. B. C. Walker II, eds., in Grazing Incidence and Multilayer X-ray Optical Systems, SPIE vol. 3113, p. 369377, 7/97.
12 Owens, S. M., Ullrich, J. B., Ponomarev, I.Yu., Carter, D. C., Sisk, R. C., Ho, J. X. and Gibson, W. M., “Polycapillary X-Ray Optics for Macromolecular Crystallography,” SPIE vol.2859, p.200209, 1996.
13 Kardiawarman, , York, B. R., Qian, C., Xiao, Q. F., Gibson, W. M., and MacDonald, C. A., “Application of a Multifiber Collimating Lens to Thin Film Structure Analysis,” in Hoover, R. B. and Williams, M. B., X-Ray and Ultraviolet Sensors and Applications, SPIE vol. 2519, July 1995.
14 Goodstein, D. L., States of Matter, Prentice-Hall, 1975.
15 Kennedy, R., Xiao, Q-F., Ryan, T. and York, B. R.: European Powder Diffraction Conference (EPDIC) 1997.
16 York, B. R. and Xiao, Qi-Fan, Denver X-Ray Conf., Aug 4–8, 1997, Steamboat Springs, CO.
17 Matney, K. M., Wormington, M., Bowen, D. K. and Xiao, Q.-F., Denver X-Ray Conf., Aug. 4–8, 1997, Steamboat Springs, CO.
18 Hofmann, F. A., Freinberg-Trufas, C. A., Owens, S. M., Padiyar, S. D., MacDonald, C. A., “Focusing of Synchrotron Radiation with Polycapillary Optics,” Nuclear Instruments and Methods in Physics Research, Section B, Dec 1997, p. 145150.
19 Rath, B. K., Aloisi, D. C., Bilderback, D. H., Gao, N., Gibson, W. M., Hofmann, F. A., Homan, B. E., Jezewski, C. J., Klotzko, I. L., Mitchell, J. M., Owens, S. M., Ullrich, J. B., Wang, Lei, Wells, G. M., Xiao, Q. F. and MacDonald, C. A., “Effects of intense x-ray radiation on polycapillary fiber performance,” in R. B. Hoover and M. B.Williams, X-Ray and Ultraviolet Sensors and Applications, SPIE vol.2519, July 1995 p207217.
20 Rath, B. K., Hagelberg, F. B., Homan, B. E. and MacDonald, C. A., “Synchrotron White Beam Thermal Loading on Polycapillary X-ray Optics,” in press, NIM A.
21 Rath, B. K., Gibson, W. M., , Lei Wang, Homan, B. E. and MacDonald, C. A., ” submitted, Journal of Applied Physics.
22 Ho, J. X., Snell, E. H., Sisk, C. R., Ruble, J. R., Carter, D. C., Owens, S. M. and Gibson, W. M., ” accepted for publication Acta Cryst. D, 1997.

Related content

Powered by UNSILO

Polycapillary X-Ray Optics for Thin Film Strain and Texture Analysis

  • F. A. Hofmann (a1), W. M. Gibson (a1), S. M. Lee (a1), C. A. Macdonald (a1), J. B. Ullrich (a2) and N. GAO (a2)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed.