Investigation of biocompatibility on nitrogen-doped a-C:H film coating scaffold surface in in-vivo and in-vitro tests

  • Yasuharu Ohgoe (a1), Tomoaki Wada (a1), Yasuyuki Shiraishi (a2), Hidekazu Miura (a2), Kenji K. Hirakuri (a3), Akio Funakubo (a1), Tomoyuki Yambe (a2) and Yasuhiro Fukui (a1)...

Abstract

In this study, in order to investigate biocompatibility of nitrogen-doped hydrogenated amorphous carbon (a-C:H:N) film coating segmented polyurethane (SPU) scaffold fiber sheet (a-C:H:N-Scaffold) in in-vitro test, mouse fibroblasts (NIH 3T3) cells were grown on the a-C:H:N-Scaffold. The cell behavior was monitored by time-lapse imaging system. Additionally, the a-C:H:N-Scaffold was implanted at partial aorta descendens of a goat for 35 days. The surface morphology, composition, and wettability of the a-C:H:N-scaffold was estimated by Scanning Electron Microscope (SEM), X-ray photoelectron spectrometer (XPS), and contact angle measurement. In in-vitro test, it was observed that a-C:H:N film coating had a facilitatory effect on cell motility and cell growth. In in-vivo test, it was observed that the a-C:H:N-Scaffold surface was uniformly covered by neointima. The a-C:H:N-Scaffold surface had no thrombus formation as an inflammatory reaction and it was shown that the a-C:H:N film coating had a good blood compatibility. These results suggest that a-C:H:N film coating has good cytocompatibility and blood compatibility and it is a promising approach for improvement of biocompatibility of biomaterial surfaces.

Copyright

References

Hide All
1. Prasad, C. K., and Krishnan, L. K., Acta Biomaterialia 4, 182 (2008).
2. Johnson, K. K., Russ, P. D., Bair, J. H., and Friend, G. D., AJR 154, 405 (1990).
3. Bahney, C. S., Hsu, C. W., Yoo, J. U., West, J. L., and Johnstone, B., The FASEB Journal 25, 1488 (2011).
4. Chan, B. P. and Leon, K. W., European Spine Journal 17, 467 (2008).
5. Caracciolo, P. C., de Queiroz, A. A. A., Higa, O. Z., Buffa, F., Abraham, G. A., Acta Biomaterialia 4, 976 (2008).
6. Ohgoe, Y., Matsuo, H., Nonaka, K., Yaguchi, T., Kanasugi, K., Hirakuri, K. K., Funakubo, A., and Fukui, Y., Mater. Res. Soc. Symp. Proc. 1138, 1138-FF12-03 (2011).
7. Lackner, J. M., Waldhauser, W., BHM 155, 528 (2010).
8. Cheng, H. C., Chiou, S. Y., Liu, C. M., Lin, M. H., Chen, C. C., Ou, K. L., J. Alloys Compd. 477, 931 (2009)
9. Roy, R. K., Ahmed, Sk. F., Yi, J. W., Moon, M.-W., Lee, K.-R., Jun, Y., Vacuum 83, 1179 (2009).
10. Ma, W. J., Ruys, A. J., Mason, R. S., Martin, P. J., Bendavid, A., Liu, Z., Ionescu, M., Zreiqat, H., Biomaterials 28, 1620 (2007).
11. Roy, R. K., Lee, K. R., J. Biomed. Mater. Res. Part B 83B, 72 (2007).
12. Robertson, J., Diamond Relat. Mater. 12, 79 (2003).
13. Hasebe, T., Hotta, A., Kodama, H, Kamijo, A., Takahashi, K., Suzuki, T., New Diamond and Frontier Carbon Technology 17 , 263 (2007).
14. Yang, P., Huang, N., Leng, Y. X., Yao, Z. Q., Zhou, H. F., Maitz, M., Leng, Y., Chu, P. K., NIM B 242, 22 (2006)
15. Nitta, Y., Okamoto, K., Nakatani, T., Hoshi, H., Homma, A., Tatsumi, E., Taenaka, Y., Diamond Relat. Mater. 17, 1972 (2008).
16. Majumdar, A., Schröder, K., and Hippler, R., J. Appl. Phys. 104, 074702 (2008).
17. Kubová, O., Švorčík, V., Heitz, J., Moritz, S., Romanin, Ch., Matĕjka, P., Macková, A., Thin solid films 515, 6765 (2007).
18. Arnold, M., Cavalcanti-Adam, E.A., Glass, R., Blummel, J., Eck, W., Kantlehner, M., Kessler, H. and Spatz, J.P., ChemPhysChem 5, 383 (2004).
19. Biazar, E., Heidari, M., Asefnezhad, A., Montazeri, N., Int. J. Nanomedicine 6, 631639 (2011).
20. Khan, S. P., Auner, G. G., Newaz, G. M., Nanomedicine:NBM 1, 135–129 (2005).

Keywords

Investigation of biocompatibility on nitrogen-doped a-C:H film coating scaffold surface in in-vivo and in-vitro tests

  • Yasuharu Ohgoe (a1), Tomoaki Wada (a1), Yasuyuki Shiraishi (a2), Hidekazu Miura (a2), Kenji K. Hirakuri (a3), Akio Funakubo (a1), Tomoyuki Yambe (a2) and Yasuhiro Fukui (a1)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed