Hostname: page-component-78c5997874-t5tsf Total loading time: 0 Render date: 2024-11-17T23:27:27.567Z Has data issue: false hasContentIssue false

Formation, Characterization, Protein Resistance, and Reactivity of Cl3Si(CH2)11(OCH2CH2)3OH Self-Assembled Monolayers

Published online by Cambridge University Press:  01 February 2011

Jiehyun Seong
Affiliation:
Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139-4307, U.S.A.
Seok-Won Lee
Affiliation:
Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139-4307, U.S.A.
Paul E. Laibinis
Affiliation:
Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139-4307, U.S.A.
Get access

Abstract

We report a method for generating tri(ethylene glycol)-terminated-n-alkyltrichlorosiloxane monolayers on SiO2 surfaces. These chemisorbed films, with a thickess of ∼2-3 nm, provide an oligo(ethylene glycol) surface that reduces the nonspecific adsorption of proteins and hydroxyl attachment sites for covalently immobilizing biomolecules to the substrate. These mono-molecular films were formed by adsorbing an acetoxy-tri(ethylene glycol)-terminated n-alkyltrichlorosilane, CH3(C=O)O(CH2CH2O)3(CH2)11SiCl3, onto glass and Si/SiO2 substrates, where the terminal acetate provided a protecting group for the hydroxyl functionality during self-assembly of the film. After formation of the monolayer, the acetate functionality was reduced chemically to form films exposing a covalently attached -(OCH2CH2)3OH terminus at a density of ∼3[.dotmath]1014 molecules/cm2. Protein adsorption studies verified that the films exhibited notable resistances against the non-specific adsorption of various proteins. Chemical modification of the -(OCH2CH2)3OH surface with protein A provided a non-adsorbing surface for selective immobilization of immunoglobulins.

Type
Research Article
Copyright
Copyright © Materials Research Society 2002

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Singh, P., Sharma, B.P. and Tyle, P., Diagnostics in the Year 2000: Antibody, Biosensor, and Nucleic Acid Technologies (Van Nostrand Reinhold, 1993).Google Scholar
2. Kenausis, G.L., Vörös, J., Elbert, D.L., Huang, N., Hofer, R., Ruiz-Taylor, L., Textor, M., Hubbell, J.A. and Spencer, N.D., J. Phys. Chem. B 104, 3298 (2000).Google Scholar
3. Ruiz-Taylor, L.A., Martin, T.L., Zaugg, F.G., Witte, K., Indermuhle, P., Nock, S. and Wagner, P., Proc. Natl. Acad. Sci., USA 98, 852 (2001).Google Scholar
4. Huang, N.P., Vörös, J., DePaul, S.M., Textor, M. and Spencer, N.D., Langmuir 18, 220 (2002).Google Scholar
5. Lee, S.-W. and Laibinis, P.E., Biomaterials 19, 1669 (1998).Google Scholar
6. Pale-Grosdemange, C., Simon, E.S., Prime, K.L. and Whitesides, G.M., J. Am. Chem. Soc. 113, 12 (1991).Google Scholar
7. Prime, K.L and Whitesides, G.M., J. Am. Chem. Soc. 115, 10714 (1993).Google Scholar