Hostname: page-component-8448b6f56d-xtgtn Total loading time: 0 Render date: 2024-04-18T07:56:42.573Z Has data issue: false hasContentIssue false

Emeraldine Base Thin Film Carbon Dioxide Sensor

Published online by Cambridge University Press:  01 February 2011

Mihai Irimia-Vladu
Affiliation:
irimimi@auburn.edu, Auburn University, Materials Research and Education Center, 275 Wilmore Laboratories, Auburn, Alabama, 36849, United States, (334)-444-3620, (334)-444-3400
Jeffrey W. Fergus
Affiliation:
jwfergus@eng.auburn.edu, Auburn University, Materials Research and Education Center, United States
Get access

Abstract

A thin film of emeraldine base polyaniline in NMP was cast on an interdigitated electrode and its conductivity investigated by impedance spectroscopy. The thin film responded to carbonic acid solutions of various pHs lower than 5. In general, an emeraldine base (EB) to emeraldine salt (ES) transformation occurs by protonation when the pH is less than 4. In the present case, the stages that occur prior to the onset of changes in total conductivity are detected by impedance spectroscopy. The sensor output was stable and reversible over a period of 3 months of testing.

Type
Research Article
Copyright
Copyright © Materials Research Society 2006

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

[1] Chiang, J.C. and MacDiarmid, A.G., Synthetic Metals 13, 193 (1986).Google Scholar
[2] MacDiarmid, A.C., Chiang, J.C., Richter, A.F. and Epstein, A.J., Synth. Met. 18, 285 (1987).Google Scholar
[3] Jozefowicz, M., Epstein, A.J., Tang, X., Synth. Met. 46, 337 (1992).Google Scholar
[4] Angelopoulos, M., Ray, A., MacDiarmid, A.G. and Epstein, A.J., Synth. Met. 21, 21 (1987).Google Scholar