Effect of Thermal Treatments on the Transduction Behaviors of Conductometric Hydrogen Gas Sensors Integrated with HCl-Doped Polyaniline Nanofibers

  • Pen-Cheng Wang (a1), Yaping Dan (a2), Luke A. Somers (a3), Alan G. MacDiarmid (a4) and A.T. Charlie Johnson (a5)...

Abstract

We present the effect of thermal treatments on the transduction behaviors of HCl-doped polyaniline (PANI) nanofibers integrated in conductometric devices upon exposure to 1% H2 (carried by N2). After drying in N2 at 25ºC for 12 hours, devices showed a ∼10% decrease in electrical resistance upon exposure to 1% H2. However, devices subject to 12-hour drying in N2 at 25ºC followed by further thermal treatments in N2 at 100ºC, 164ºC or 200ºC for 30 minutes showed different transduction behaviors. Specifically, devices subject to thermal treatments at 100ºC and 164ºC showed a decrease in electrical resistance by ∼7% and <0.5%, respectively. More interestingly, the device subject to thermal treatment at 200ºC showed a transduction behavior with opposite polarity, i.e. a ∼5% increase in electrical resistance upon exposure to 1% H2. SEM, FTIR and TGA were employed to investigate the effect of thermal treatments on the morphology and chemical characteristics of HCl-doped polyaniline nanofibers. The results indicated that the change in the devices' interesting transduction behaviors might be related to the thermal treatment effects on the HCl-doped PANI nanofibers in (i) removal of adsorbed water, and (ii) crosslinking and/or degradation of polymer backbones.

Copyright

References

Hide All
1. Cho, S.J., Song, K.S., Kim, J.W., Kim, T.H., Choo, K., Fuel Chemistry Division, 224th National Meeting of the American Chemical Society 47, 790 (2002).
2. Cho, S.J., Choo, K., Kim, D.P., Kim, J.W., Catal. Today 120, 336 (2007).
3. Huang, Q., Wei, C., Conference Abstract, 205th Meeting of the Electrochemical Society, San Antonio, TX, USA, May 9-14, 2004.
4. Jurczyk, M.U., Kumar, A., Srinivasan, S., Stefanakos, E., Int. J. Hydrogen Energy 32, 1010 (2007).10.1016/j.ijhydene.2006.07.012
5. Panella, B., Kossykh, L., Dettlaff-Weglikowska, U., Hirscher, M., Zerbi, G., Roth, S., Synth. Met. 151, 208 (2005).
6. MacDiarmid, A.G., Angew. Chem. Int. Ed. 40, 2581 (2001).
7. Virji, S., Kaner, R.B., Weiller, B.H., J. Phys. Chem. B 110, 22266 (2006).
8. Sadek, A.Z., Wlodarski, W., Kalantar-Zadeh, K., Baker, C., Kaner, R.B., Sens. Actuators A 139, 53 (2007).
9. Wang, P-C., Venancio, E.C., Sarno, D.M., MacDiarmid, A.G., unpublished results (Nanofibers of polyaniline, presented by MacDiarmid, A.G. at ONR Polymer Review Meeting, Arlington, VA, USA, May 5, 2004).
10. MacDiarmid, A.G., Wang, P-C., Venancio, E.C., Morphology manipulation of polymerized aniline synthesized in an aqueous medium, patent disclosure, filed September 23, 2004.
11. Baker, C.O., Weiller, B.H., Kaner, R.B., e-mail communications, May 22, 2006-June 12, 2006.
12. Tang, J., Jing, X., Wang, B., Wang, F., Synth. Met., 24, 231 (1988).
13. Traore, M.K., Stevenson, W.T.K., McCormick, B.J., Dorey, R.C., Wen, S., Meyers, D., Synth. Met., 40, 137 (1991).
14. Venancio, E.C., Wang, P-C., MacDiarmid, A.G., Heben, M.J., unpublished results.
15. Sun, Y., Ph.D. Thesis, 1991, University of Pennsylvania, Philadelphia, USA.

Keywords

Effect of Thermal Treatments on the Transduction Behaviors of Conductometric Hydrogen Gas Sensors Integrated with HCl-Doped Polyaniline Nanofibers

  • Pen-Cheng Wang (a1), Yaping Dan (a2), Luke A. Somers (a3), Alan G. MacDiarmid (a4) and A.T. Charlie Johnson (a5)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed.