Skip to main content Accessibility help
×
Home

Detection of Respiratory Viruses with Plastic High Throughput Screening Devices

  • Zhengshan Zhao (a1), Gerardo A. Diaz-Quijada (a2), Régis Peytavi (a3), Éric LeBlanc (a4), Johanne Frenette (a5), Guy Boivin (a6), Jim V. Zoval (a7), Marc Madou (a8), Michel M. Dumoulin (a9), Teodor Veres (a10) and Michel G. Bergeron (a11)...

Abstract

Microarrays have become one of the most convenient tools for high throughput screening and have catalyzed major advances in genomics and proteomics. Other important applications can be found in medical diagnostics, detection of biothreats, drug discovery, etc. Integration of microarrays with microfluidic devices can be highly advantageous in terms of portability, shorter analysis time and lower consumption of expensive biological analytes. Since fabrication of microfluidic devices using traditional materials such as glass is rather expensive, there is a high interest in employing polymeric materials as a low cost alternative suitable for mass production. We present proof-of-concept DNA arrays on a plastic platform for the detection of four important respiratory pathogens: Influenza A virus, respiratory syncytial virus, human enterovirus, and human metapneumovirus.

This was accomplished by amplifying the genetic material from the viruses and simultaneously labeling the amplicons with a fluorescent dye (Cy3) via a highly sensitive multiplex Reverse Transcription Polymerase Chain Reaction (RT-PCR). The resultant RT-PCR product was hybridized, without further purification, with an array of specific oligonucleotide probes (20 mers) that had been covalently bound to a plastic substrate. Results indicate a high signal to background ratio that is comparable to commercially available microarray glass slides. In addition, 5 minute hybridization on this plastic substrate has been demonstrated using a centrifugal microfluidic platform, paving the way to a rapid medical diagnostic device for point-of-care use that is based on a low-cost portable Micro-Total-Analysis-System (μ-TAS).

Copyright

References

Hide All
1. Peytavi, R., Raymond, F. R., Gagné, D., Picard, F. J., Jia, G., Zoval, J., Madou, M., Boissinot, K., Boissinot, M., Bissonnette, L., Ouellette, M., and , B. M. G., Clin. Chem., 51, 1836, (2005).
2. Diaz-Quijada, G. A., Peytavi, R., Nantel, A., Roy, E., Bergeron, M. G., Dumoulin, M. M., and Veres, T., “Towards low cost disposable high throughput screening devices,” Proceedings of the Materials Research Society, Boston, MA, 2005.
3. Elnifro, E. M., Ashshi, A. M., Cooper, R. J., and Klapper, P. E., Clin. Microbiol. Rev., 13, 559, (2000).
4. Cha, R. S. and Thilly, W. G., PCR Methods Appl., 3, S18, (1993).
5. Dieffenbach, C. W., Lowe, T. M. J., and Dveksler, G. S., PCR Methods Appl., 3, S30, (1993).
6. Henegariu, O., Heerema, N. A., Dlouhy, S. R., Vance, G. H., and Vogt, P. H., BioTechniques, 23, 504, (1997).

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed