Skip to main content Accessibility help
×
Home

Combined Simulation and Measurement Study of Temperature Uniformity in Rapid Thermal Processing

  • Yur-Tsai Lin (a1), Ravi Subrahmanyan (a1) and A. R. Sitaram (a1)

Abstract

Modeling and simulation of rapid thermal processing has been studied extensively in the past. This work presents the results of a combined simulation and measurement study of a commercial multilamp RTP chamber. The simulations were used to estimate the contributions of different geometrical, material, process, and physical effects on temperature uniformity. The physical effects considered in the simulations included radiation, thermal conduction, transient effects during ramp up and cool down and the effects of patterns on the wafer surface. The effects were corroborated by direct temperature measurements using thermocouple embedded wafers, and the results were used to reliably calculate stress effects. The stress distributions were determined analytically in cases without surface films on the wafer. In the case of wafers with surface films, stress distributions were calculated based on thermal strains. This study allows us to concentrate efforts on increasing temperature uniformity to those areas where the greatest benefits in terms of yield and film uniformity can be obtained.

Copyright

References

Hide All
[1] Hill, C., Jones, S., and Boys, D., in Reduced Thermal Processing for ULSI, (Plenum, New York, 1989).
[2] Lord, H.A., IEEE Trans. Semiconductor Manufacturing, 1 (3) 105 1989.
[3] Kersch, A., Schafer, H., and Werner, C., in Proc. International Electron Devices Meeting, page 883, 1991
[4] FIDAP Users Manual, Fluid Dynamic International, 1992.
[5] Lin, Y-T., “Temperature Uniformity in Rapid Thermal Processing Equipment”, Motorola (APRDL) Internal Report, 1992.
[6] Kakoschke, R. in Mat. Res. Soc. Proc., 1991
[7] Vandenabeele, P., Maex, K., and DeKeersmaecker, R., MRS Spring Meeting, Symposium B, 1989.
[8] Seithoff, H. and Haasen, P., in Lattice Defects in Semiconductors, p. 491, Univ. of Tokyo, 1968.

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed