Skip to main content Accessibility help
×
Home

A Biosensor System for the Detection of Salmonella Typhimurium Using Multiple Phage-based Magnetoelastic Biosensors

  • Wen Shen (a1), Yugui Li (a2), Huiqin Chen (a3), Shin Horikawa (a4) and B. A. Chin (a5)...

Abstract

Magnetoelastic (ME) sensors provide a fast, sensitive method to detect bacteria with smaller sensors have higher mass sensitivity for detecting lower concentrations of bacteria. However, signals from smaller sensors are weaker and have more noise due to manufacturing defects. In this paper, we present a biosensor system for the detection of Salmonella typhimurium using multiple magnetoelastic sensors, each with the size of 2000 × 400 × 30 μm. The sensors are immobilized with E2 phage, which specifically binds with S. typhimurium. Unlike traditional methods, our system uses a step pulse to “shock” the sensor, causing it to vibrate at its natural resonance frequency and produce a signal in the pickup coil due to reverse magnetostriction. A Fast Fourier Transform (FFT) was used to determine the resonance frequency. As the biosensor captures S. typhimurium cells, its mass increases with a corresponding decrease of its resonance frequency.The detection system was composed of one coil with a reference sensor to monitor stability, and another coil with three measurement sensors separated in three tubes for simultaneous detection of bacteria. With multi-sensors the effect of a manufacturing defect is decreased and we get the benefit of averaging for more accurate and reliable results. Stability tests show that the variance of frequency detection is less than 122 ppm of its resonance frequency. SEM pictures of the sensor surface show a uniform binding of S. typhimurium cells. Cells were counted and the mass change calculated. The measured frequency change corresponds well to the theoretical change. The results show that the multiple phage based ME biosensors are able to simultaneously detect S. typhimurium and offer good sensitivity and reliability of detection.

Copyright

References

Hide All
1 Grimes, C. A., Ong, K. G., Loiselle, K., Stoyanov, P. G., Kouzoudis, D., Liu, Y., Tong, C. and Tefiku, F., Smart Materials and Structures 8 (5), 639646 (1999).
2 Guntupalli, R., Lakshmanan, R. S., Hu, J., Huang, T. S., Barbaree, J. M., Vodyanoy, V. and Chin, B. A., Journal of Microbiological Methods 70 (1), 112118 (2007).
3 Xie, F., Yang, H., Li, S., Shen, W., Wan, J., Johnson, M. L., Wikle, H. C., Kim, D.-J. and Chin, B. A., Intermetallics 17 (4), 270273 (2009).
4 Shen, W., Lakshmanan, R. S., Mathison, L. C., Petrenko, V. A. and Chin, B. A., Sensors and Actuators B: Chemical 137 (2), 501506 (2009).
5 Shen, W., Mathison, L. C., Petrenko, V. A. and Chin, B. A., Journal of Physics D: Applied Physics 43 (1), 015004.
6 Honeywell, , (2008).
7 Huang, S., Hu, J., Wan, J., Johnson, M. L., Shu, H. and Chin, B. A., Materials Science and Engineering: C 28 (3), 380386 (2008).
8 Sorokulova, I. B., Olsen, E. V., Chen, I. H., Fiebor, B., Barbaree, J. M., Vodyanoy, V. J., Chin, B. A. and Petrenko, V. A., Journal of Microbiological Methods 63 (1), 5572 (2005).
9 Shen, W., Mathison, L. C., Petrenko, V. A. and Chin, B. A., Applied Physics Letters 96 163502 (2010).

Keywords

Related content

Powered by UNSILO

A Biosensor System for the Detection of Salmonella Typhimurium Using Multiple Phage-based Magnetoelastic Biosensors

  • Wen Shen (a1), Yugui Li (a2), Huiqin Chen (a3), Shin Horikawa (a4) and B. A. Chin (a5)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed.