Hostname: page-component-77ffc5d9c7-jwc9c Total loading time: 5.236 Render date: 2021-04-23T03:28:28.345Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": false, "newCiteModal": false, "newCitedByModal": true }

Secondary Ion Mass Spectrometry with Gas Cluster Ion Beams

Published online by Cambridge University Press:  17 March 2011

Noriaki Toyoda
Affiliation:
Material Processing Center, Massachusetts Institute of Technology 77 Massachusetts Avenue, Cambridge, MA 02139.
Jiro Matsuo
Affiliation:
Ion Beam Engineering Experimental Lab., Kyoto Univ. Sakyo, Kyoto, 606-8501, JAPAN
Takaaki Aoki
Affiliation:
Ion Beam Engineering Experimental Lab., Kyoto Univ. Sakyo, Kyoto, 606-8501, JAPAN
Shunichi Chiba
Affiliation:
Ion Beam Engineering Experimental Lab., Kyoto Univ. Sakyo, Kyoto, 606-8501, JAPAN
Isao Yamada
Affiliation:
Laboratory of Advanced Science and Technology for Industry, Himeji Institute of Technology, Hyogo, 678-1205, JAPAN
David B. Fenner
Affiliation:
Epion Corporation, 37 Manning Road, Billerica, MA 01821.
Richard Torti
Affiliation:
Epion Corporation, 37 Manning Road, Billerica, MA 01821.
Get access

Abstract

Secondary Ion Mass Spectrometry (SIMS) with Gas Cluster Ion Beams (GCIB) was studied with experiments and molecular dynamics (MD) simulations to achieve a high-resolution depth profiling. For this purpose, it is important to prevent both ion-mixing and the surface roughening due to energetic ions. As the Ar cluster ion beam shows surface smoothing effects and high secondary-ion yield in the low-energy regime, the cluster ion beam would be suitable for the primary ion beam of SIMS. From MD simulations of Ar cluster ion impact on a Si substrate, the ion-mixing is heavier than for Ar monomer ions at the same energy per atom, because the energy density at the impact point by clusters is extremely high. However, the sputtering yields with Ar cluster ions are one or two orders of magnitude higher than that with Ar monomer ions at the same energy per atom. Comparing at the ion energy where the ion-mixing depths are the same by both cluster and monomer ion impacts, cluster ions show almost ten times higher sputtering yield than Ar monomer ions. Preliminary experiment was done with a conventional SIMS detector and a mass resolution of several nm was achieved with Ar cluster ions as a primary ion beam.

Type
Research Article
Copyright
Copyright © Materials Research Society 2001

Access options

Get access to the full version of this content by using one of the access options below.

References

1. Clegg, J.B., Beall, R.B., “Secondary Ion Mass Spectroscopy SIMS IV”, ed. by Benninghoven, A., Evans, C.A., McKeegan, k.D., Storms, H.A., Werner, H.W., John Wiley (1990).Google Scholar
2. Akizuki, M., Matsuo, J., Harada, M., Ogasawara, S., Doi, A., Yoneda, K., Yamaguchi, T., Takaoka, G.H., Ascheron, C.E. and Yamada, I., Nucl. Instr. And Meth. B99, 225 (1995).Google Scholar
3. Toyoda, N., Hagiwara, N., Matsuo, J. and Yamada, I., Nucl. Instr. And Meth. B148, 639 (1999).CrossRefGoogle Scholar
4. Fenner, D.B., Torti, R.P., Allen, L.P., Toyoda, N., Kirkpatrick, A.R., Greer, J.A., DiFilippo, V. and Hautala, J., Mat. Res.Soc. Symp. Proc. 585, 27 (2000).CrossRefGoogle Scholar
5. Goto, K., Matsuo, J., Tada, Y., Tanaka, T., Momiyama, Y., Sugii, T. and Yamada, I., IEDM Tech. Dig., 471 (1997).Google Scholar
6. Matsuo, J., Toyoda, N., Akizuki, M. and Yamada, I., Nucl. Instr. and Meth. B121, 459 (1997).CrossRefGoogle Scholar
7. Biersack, J.P., Berg, S. and Nender, C., Nucl. Instr. and Meth. B59/60, 21 (1991).CrossRefGoogle Scholar
8. Biersack, J.P., Nucl. Instr. and Meth. B133, 398 (1999).CrossRefGoogle Scholar
9. Aoki, T., Chiba, S., Matsuo, J., Yamada, I. and Biersack, J.P., Nucl. Instr. and Meth. B, to be published.Google Scholar
10. Stillinger, F.H. and Weber, T.A., Phys. Rev. B31, 5262 (1985).CrossRefGoogle Scholar
11. Ziegler, J.F., Biersack, J.P. and Littmark, U., “The stopping and range of ions in solids”, Pergamon press, New York, 1985, p.321.Google Scholar

Full text views

Full text views reflects PDF downloads, PDFs sent to Google Drive, Dropbox and Kindle and HTML full text views.

Total number of HTML views: 0
Total number of PDF views: 7 *
View data table for this chart

* Views captured on Cambridge Core between September 2016 - 23rd April 2021. This data will be updated every 24 hours.

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Secondary Ion Mass Spectrometry with Gas Cluster Ion Beams
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Secondary Ion Mass Spectrometry with Gas Cluster Ion Beams
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Secondary Ion Mass Spectrometry with Gas Cluster Ion Beams
Available formats
×
×

Reply to: Submit a response


Your details


Conflicting interests

Do you have any conflicting interests? *