Hostname: page-component-559fc8cf4f-sbc4w Total loading time: 0.649 Render date: 2021-03-06T02:38:44.632Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": false, "newCiteModal": false, "newCitedByModal": true }

Results of a Stemmed Bone Ingrowth HIP Resurfacing Arthroplasty in the Canine

Published online by Cambridge University Press:  22 February 2011

W. C. Kim
Affiliation:
Division of Orthopaedic Surgery, UCLA School of Medicine, Los Angeles, California 90024
H. Rechl
Affiliation:
Division of Orthopaedic Surgery, UCLA School of Medicine, Los Angeles, California 90024
H. C. Amstutz
Affiliation:
Division of Orthopaedic Surgery, UCLA School of Medicine, Los Angeles, California 90024
K. Hermens
Affiliation:
Division of Orthopaedic Surgery, UCLA School of Medicine, Los Angeles, California 90024
P. F. O'Carroll
Affiliation:
Division of Orthopaedic Surgery, UCLA School of Medicine, Los Angeles, California 90024
M. Kabo
Affiliation:
Division of Orthopaedic Surgery, UCLA School of Medicine, Los Angeles, California 90024
Get access

Abstract

A stemmed bone ingrowth hip resurfacing arthroplasty designed for use with bone deficient femoral heads raises concerns of stress shielding and is investigated in this study. Ten CoCr bone ingrowth hip resurfacing devices were implanted in five adult canines. Design consisted of a 6mm deep cylindrical cavity with porous beaded surface of 150um pore size and Imm nominal depth. A 3mm diameter smooth CoCr stem was eccentrically fixed to the component for additional fixation with threaded nut at the lateral cortex. Femoral head was reamed for interference fit with hole for the stem placed superiorly. Acrylic fixed polyethylene cups were used for acetabular components. Animals were followed with serial radiographs to sacrifice at 73 to 267 days. After sacrifice microradiographs of ground sections and histologic specimens were evaluated for bone ingrowth, remodeling, and femoral neck attenuation. All specimens showed well ingrown bone at the porous layer. Bone remodeling showed preservation of proximal femoral neck cancellous trabecular pattern and medial cortical support. Resorption of bone at the implant rim and femoral neck thinning were, however, present. Two specimens had neck thinning of 10% or less, four of 10 to 25%, three of 25 to 50%, and one greater than 50%. There was no correlation with time to sacrifice for parameters evaluated. Results indicate preservation of the compressive stresses through the femoral head. Resorption of bone at the rim and femoral neck attenuation, however, indicates load sharing between the implant and bone. Though a lower modulus material such as titanium would decrease load sharing, the geometrical design insures the presence of stress distribution anomalies.

Type
Research Article
Copyright
Copyright © Materials Research Society 1986

Access options

Get access to the full version of this content by using one of the access options below.

References

1. Kim, W. C., Amstutz, H.C., et al.: Proceedings of the Twelfth Open Scientific Meeting of the Hip Society, C.V. Mosby Co., St. Louis, p. 211, 1984.Google Scholar
2. Carter, D.R. and Vasu, R.: J. Biomechanics, 17:737, 1984.CrossRefGoogle Scholar
3. Hedley, A.K., Amstutz, H.C., et al.: Proceedings of the Seventh Open Scientific Meeting of The Hip Society, C.V. Mosby Co., St. Louis, p. 160, 1979.Google Scholar
4. GerngroB, H., Claes, L., and Burri, C.: In Clinical Applications of Biomaterials, edited by Lee, A.J.C. (John Wiley and Sons Ltd.), Chichester, p. 31, 1982.Google Scholar

Full text views

Full text views reflects PDF downloads, PDFs sent to Google Drive, Dropbox and Kindle and HTML full text views.

Total number of HTML views: 0
Total number of PDF views: 8 *
View data table for this chart

* Views captured on Cambridge Core between September 2016 - 6th March 2021. This data will be updated every 24 hours.

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Results of a Stemmed Bone Ingrowth HIP Resurfacing Arthroplasty in the Canine
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Results of a Stemmed Bone Ingrowth HIP Resurfacing Arthroplasty in the Canine
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Results of a Stemmed Bone Ingrowth HIP Resurfacing Arthroplasty in the Canine
Available formats
×
×

Reply to: Submit a response


Your details


Conflicting interests

Do you have any conflicting interests? *