Hostname: page-component-559fc8cf4f-s65px Total loading time: 0.246 Render date: 2021-02-27T10:21:36.165Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": false, "newCiteModal": false, "newCitedByModal": true }

Process Monitoring for Fabrication of Mercuric Iodide Room Temperature Radiation Detectors

Published online by Cambridge University Press:  22 February 2011

J. M. Van Scyoc
Affiliation:
Carnegie Mellon University, Department of Electrical and Computer Engineering, Pittsburgh, PA 15213
T. E. Schlesinger
Affiliation:
Carnegie Mellon University, Department of Electrical and Computer Engineering, Pittsburgh, PA 15213
H. Yao
Affiliation:
University of Nebraska, Center for Microelectronic and Optical Materials Research, and Department of Electrical Engineering, Lincoln, NE 68588
R. B. James
Affiliation:
Sandia National Laboratories, Advanced Materials Research Division, Livermore, CA 94550
M. Natarajan
Affiliation:
TN Technologies, Inc., Round Rock, TX 78680
X. J. Bao
Affiliation:
TN Technologies, Inc., Round Rock, TX 78680
J. S. Iwanczyk
Affiliation:
Xsirius, Inc., Camarillo, CA 93012
B. E. Patt
Affiliation:
Xsirius, Inc., Camarillo, CA 93012
L. van den Berg
Affiliation:
EG&G Energy Measurements, Goleta, CA 93116
Get access

Abstract

In the fabrication of mercuric iodide room temperature radiation detectors, as in any semiconductor process, the quality of the final device can be very sensitive to the details of the processing steps. Each processing step can either reduce the intrinsic defects and those extrinsic defects introduced by earlier steps, or it can introduce new defects. In mercuric iodide these defects can act as trapping and recombination centers, thereby degrading immediate device performance or leading to long-term reliability problems. With careful study and monitoring of each step, the process can be modified to improve the end product. In this work we used several techniques to study processing steps and their effects. Photoluminescence spectroscopy and photoionization revealed defects introduced during processing. One critical step is the formation of electrical contacts, as both the material choice and deposition method have an impact. Four point probe sheet resistance methods were used to characterize the loss of material from the contact as it reacted with or moved into the bulk semiconductor. Ellipsometry was used to characterize the intrinsic optical functions of the material, and to study the effects of surface aging on these functions. Results from this work provide suggestions for the modification and monitoring of the detector fabrication process.

Type
Research Article
Copyright
Copyright © Materials Research Society 1994

Access options

Get access to the full version of this content by using one of the access options below.

References

1. Willig, W. R., Nucl. Instrum. Methods 96, 615 (1971).CrossRefGoogle Scholar
2. Malm, H. L., IEEE Trans. Nucl. Sci. NS–19, 263 (1972).CrossRefGoogle Scholar
3. Ponpon, J. P., Stuck, R., and Siffert, P., Nucl. Instrum. Methods 119, 297 (1974).CrossRefGoogle Scholar
4. Howes, J. H. and Watling, J., Mat. Res. Soc. Symp. Proc. 16, 207 (1983).CrossRefGoogle Scholar
5. Malm, H. L., Raudoff, T. W., Martina, M., and Zanio, K. R., IEEE Trans. Nucl. Sci. NS–20, 500 (1973).CrossRefGoogle Scholar
6. Whited, R. C. and Schieber, M., Nucl. Instrum. Methods 162, 119 (1979).CrossRefGoogle Scholar
7. Skinner, N. L., Ortale, C., Schieber, M. M., and Berg, L. van den, Nucl. Instrum. Meth. Phys. Res. A283, 119 (1989).CrossRefGoogle Scholar
8. Bao, X. J., Schlesinger, T. E., James, R. B., Stulen, R. H., Ortale, C., and Cheng, A. Y., J. Appl. Phys. 68, 86 (1990).CrossRefGoogle Scholar
9. James, R. B., Bao, X. J., Schlesinger, T. E., Markakis, J. M., Cheng, A. Y., and Ortale, C., J. Appl. Phys. 66, 2578 (1989).CrossRefGoogle Scholar
10. Bao, X. J., Schlesinger, T. E., James, R. B., Gentry, G. L., Cheng, A. Y., and Ortale, C., J. Appl. Phys. 69, 4247 (1991).CrossRefGoogle Scholar
11. Bao, X. J., Schlesinger, T. E., James, R. B., Stulen, R. H., Ortale, C., and Berg, L. van den, J. Appl. Phys. 67, 7265 (1990).CrossRefGoogle Scholar
12. James, R. B., Bao, X. J., Schlesinger, T. E., Ortale, C., and Cheng, A. Y., J. Appl. Phys. 67, 2571 (1990).CrossRefGoogle Scholar
13. Scyoc, J. M. Van, Schlesinger, T. E., James, R. B., Cheng, A. Y., Ortale, C., and Berg, L. van den, Mat. Res. Soc. Symp. Proc. 302, 115 (1993).CrossRefGoogle Scholar
14. Yao, H. and Johs, B., Mat. Res. Soc. Symp. Proc. 302, 341 (1993).CrossRefGoogle Scholar

Full text views

Full text views reflects PDF downloads, PDFs sent to Google Drive, Dropbox and Kindle and HTML full text views.

Total number of HTML views: 0
Total number of PDF views: 8 *
View data table for this chart

* Views captured on Cambridge Core between September 2016 - 27th February 2021. This data will be updated every 24 hours.

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Process Monitoring for Fabrication of Mercuric Iodide Room Temperature Radiation Detectors
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Process Monitoring for Fabrication of Mercuric Iodide Room Temperature Radiation Detectors
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Process Monitoring for Fabrication of Mercuric Iodide Room Temperature Radiation Detectors
Available formats
×
×

Reply to: Submit a response


Your details


Conflicting interests

Do you have any conflicting interests? *