Hostname: page-component-54cdcc668b-rfpnn Total loading time: 0.52 Render date: 2021-03-09T09:04:04.547Z Has data issue: true Feature Flags: { "shouldUseShareProductTool": true, "shouldUseHypothesis": true, "isUnsiloEnabled": true, "metricsAbstractViews": false, "figures": false, "newCiteModal": false, "newCitedByModal": true }

Parametric Analysis of Cemented Ultrahigh Molecular Weight Polyethylene (UHMWPE) Total Hip Acetabular Cups in a Quasi-Static Loading Model

Published online by Cambridge University Press:  22 February 2011

Thomas Mittlmeier
Affiliation:
Chirurgische Klinik und Poliklinik der Universität München, Klinikum Grosshadern, Marchioninistr. 15, D-8000 Munchen 70, FRG Labor für Biomechanik und Experimentelle Orthopädie, Orthopädische Klinik und Poliklinik der Universität München, Staatliche Orthopädische Klinik München, Harlachingerstr. 51, D-8000 Munchen 90, FRG
W. Plitza
Affiliation:
Chirurgische Klinik und Poliklinik der Universität München, Klinikum Grosshadern, Marchioninistr. 15, D-8000 Munchen 70, FRG Labor für Biomechanik und Experimentelle Orthopädie, Orthopädische Klinik und Poliklinik der Universität München, Staatliche Orthopädische Klinik München, Harlachingerstr. 51, D-8000 Munchen 90, FRG
H. Schmotzer
Affiliation:
Chirurgische Klinik und Poliklinik der Universität München, Klinikum Grosshadern, Marchioninistr. 15, D-8000 Munchen 70, FRG Labor für Biomechanik und Experimentelle Orthopädie, Orthopädische Klinik und Poliklinik der Universität München, Staatliche Orthopädische Klinik München, Harlachingerstr. 51, D-8000 Munchen 90, FRG
Get access

Abstract

Owing to the interest in ever increasing lifetimes for total hip prostheses, possible failure due to aseptic loosening of the acetabular component is an issue that may require increased attention. Mechanical factors, especially the deformation behavior of the material and the stress distribution at the implant-cement and the bone-cement interfaces, presumably play an essential role in total hip failure. Therefore the experimental model of the present work makes use of rosette strain gauge techniques to evaluate the deformation behavior of cemented polyethylene cups under quasi-static loading. Standard tests in UHMWPE beam specimens confirmed that the present method is a reliable tool for strain measurements in the polymer that was tested. On the other hand, the apparent elastic modulus of UHMWPE can be shown to be markedly dependent on the testing method, the geometry, and, owing to the visco-elastic properties, dependent on the strain rate. Thus in the present work a correlation between the measured strain and the ultimate strength was not attempted. Instead a parametric analysis quantifying the influence of the cup thickness and the cement distribution on the strain pattern was performed.

Type
Research Article
Copyright
Copyright © Materials Research Society 1986

Access options

Get access to the full version of this content by using one of the access options below.

References

1. Griss, P., Hackenbrock, M., Jäger, M., Preussner, B., Schäfer, T., Seebauer, R., van Eimeren, W., and Winkler, W. in Aktuelle Probleme in Chirugie und Orthopadie, Bd. 21, edited by Burri, C., Herfarth, Ch., and Jager, M. (Hans Huber Verlag, Bern-Stuttgart-Wien, 1982), p. 2933, 59–77.Google Scholar
2. Morscher, E., Schmassmann, A., Arch. Orthop. Traumat. Surg. 101, 137 (1983).CrossRefGoogle Scholar
3. Semlitsch, M. and Willert, H.G., Med. & Biol. Eng. & Comput. 18, 511 (1980).CrossRefGoogle Scholar
4. Schneider, R. in Aktuelle Probleme in Chirurgie und Orthopädie, Bd. 24, edited by Burri, C., Hergarth, Ch., and Jdger, M. (Hans Huber Verlag, Bern-Stuttgart-Wien, 1982).Google Scholar
5. Mittlmeier, T., Plitz, W., and Russe, W. in Application of Material Sciences to the Practice of Orthopedic Surgery (Martinus Nijhoff Publ., Den Haag, in press).Google Scholar
6. Salvati, E.A., Wright, T.M., Burstein, A.H., and Jacobs, B., J. Bone Joint Surg. 61–A, 1239 (1979).CrossRefGoogle Scholar
7. Holz, U., Hemminger, W., and Gasse, H., Arch. Orthop. Traumat. Surg. 91, 121 (1978).CrossRefGoogle Scholar
8. Pedersen, D.R., Crowninshield, R.D., Brand, R.A., and Johnston, R.C., J. Biomech. 15, 305 (1982).CrossRefGoogle Scholar
9. Vasu, R., Carter, D.R., and Harris, W.H., J. Biomech. 15, 155 (1982; J. Biomech. Eng. Trans. ASME 105, 332 (1983); D.R. -Crter, R. Vasu, W.H. Harris, J. Biomech. 15, 165 (1982).CrossRefGoogle Scholar
10. Gebauer, D., Winter, W., Hager, H., Biomed. Tech. 28, 297 (1983).Google Scholar
11. Plitz, W. (private communications; Dissertation, RWTH Aachen, 1984.Google Scholar
12. Pauwels, F., Gesammelte Abhandlungen zur funktionellen Anatomie des Bewegungsapparates (Springer Verlag, Berlin-Heidelberg-New York, 1965).CrossRefGoogle Scholar
13. Dolfen, E. and Schmidt, H., Industie-Anz. Kunststoffe und Kunststoffverarbeitung 90, 2021 (1968).Google Scholar
14. Straschill, M., Seife-Ole-Fette-Wachse 98, 318, 349, 430, 498, 548 (1972); Schreyer, G. in Konstruieren mit Kunststoffen, (Carl Hanser Verlag, München, 1972), p.155.Google Scholar
15. Glücklich, D., Berichte des Instituts für Modellstatik der Universität Stuttgart, Nov. 4, 1975.Google Scholar
16. Bushelow, M., and Oh, I., presented at the 11th Ann. Meet. Soc. Biomat., San Diego, CA, 1985.Google Scholar

Full text views

Full text views reflects PDF downloads, PDFs sent to Google Drive, Dropbox and Kindle and HTML full text views.

Total number of HTML views: 0
Total number of PDF views: 7 *
View data table for this chart

* Views captured on Cambridge Core between September 2016 - 9th March 2021. This data will be updated every 24 hours.

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Parametric Analysis of Cemented Ultrahigh Molecular Weight Polyethylene (UHMWPE) Total Hip Acetabular Cups in a Quasi-Static Loading Model
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Parametric Analysis of Cemented Ultrahigh Molecular Weight Polyethylene (UHMWPE) Total Hip Acetabular Cups in a Quasi-Static Loading Model
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Parametric Analysis of Cemented Ultrahigh Molecular Weight Polyethylene (UHMWPE) Total Hip Acetabular Cups in a Quasi-Static Loading Model
Available formats
×
×

Reply to: Submit a response


Your details


Conflicting interests

Do you have any conflicting interests? *