Abstract

The effects of N-ion implantation on the corrosive-wear properties of Ti-6Al-4V, an alloy used for construction of the femoral component of artificial hip joints in humans, were tested. In corrosive-wear tests designed to simulate pertinent hip-joint parameters, electrochemical corrosion currents were measured for cylindrical samples in saline electrolyte in an arrangement which allowed the samples to be rotated between loaded polyethylene pads simultaneously with the current measurement. To further quantify material removal, Zr markers were ion-implanted into some samples so that, by use of Rutherford backscattering, material removal could be detected by changes in position of the marker relative to the surface. Corrosion currents were greatly reduced by implantation of approximately 20 at. % N, but even implantation of the Zr markers also reduced corrosion currents. The marker experiments confirmed the low rate of material removal for the implanted samples.


Type
Research Article
Copyright
Copyright © Materials Research Society 1984

Access options

Get access to the full version of this content by using one of the access options below.

Footnotes

Research sponsored in part by the Division of Materials Sciences, U. S. Department of Energy, under contract W-7405-eng-26 with the Union Carbide Corporation.


References

1. Rostoker, W. and Galante, J. O., J. Biomed. Eng. (Trans. ASME) 101, 2(1976).Google Scholar
2. Escalas, Felix, Galante, Jorge and Rostoker, William, J. Biomed. Mater. Res. 10, 175 (1976).CrossRefGoogle Scholar
3. Williams, D. F., Phys. Med. Biol. 25, 611 (1980).CrossRefGoogle Scholar
4. Merritt, Katharine, Shafer, Judith W., and Brown, Stanley A., J. Biomed. Mater. Res. 13, 101 (1979).CrossRefGoogle Scholar
5. Dumbleton, John H., Wear, 49, 297 (1978).CrossRefGoogle Scholar
6. Miller, P. D. and Holladay, J. W., Wear 2, 133 (1958/9).CrossRefGoogle Scholar
7. Buchanan, R. A., Turner, G. D., Gray, P. D., Melendez, J. G., Talbot, T. F., and McDonald, J. L., Corrosion 39, 377 (1983).CrossRefGoogle Scholar
8. Singer, I. L., Carosella, C. A., and Reed, J. R., Nucl. Inst. Methods 182/183, 923 (1981).CrossRefGoogle Scholar
9. Pethica, J. B. and Oliver, W. C., Mat. Res. Soc. Symp. Proc. 7, 373 (1982).CrossRefGoogle Scholar
(Eds. Thomas Picraux, S. and , W. J. Choyke.)Google Scholar
10. Dearnaley, G., to be published in Surface Engineering, NATO Advanced Study Inst., Les Arcs, France, July 1983, Kossowsky, R. and Singhal, Subhash C., eds.Google Scholar

Full text views

Full text views reflects PDF downloads, PDFs sent to Google Drive, Dropbox and Kindle and HTML full text views.

Total number of HTML views: 0
Total number of PDF views: 5 *
View data table for this chart

* Views captured on Cambridge Core between September 2016 - 3rd December 2020. This data will be updated every 24 hours.

Hostname: page-component-b4dcdd7-z76xg Total loading time: 1.423 Render date: 2020-12-03T21:14:34.967Z Query parameters: { "hasAccess": "0", "openAccess": "0", "isLogged": "0", "lang": "en" } Feature Flags last update: Thu Dec 03 2020 20:59:12 GMT+0000 (Coordinated Universal Time) Feature Flags: { "metrics": true, "metricsAbstractViews": false, "peerReview": true, "crossMark": true, "comments": true, "relatedCommentaries": true, "subject": true, "clr": false, "languageSwitch": true }

Send article to Kindle

To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Effect of N-Implantation on the Corrosive-Wear Properties of Surgical Ti-6Al-4V Alloy
Available formats
×

Send article to Dropbox

To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

Effect of N-Implantation on the Corrosive-Wear Properties of Surgical Ti-6Al-4V Alloy
Available formats
×

Send article to Google Drive

To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

Effect of N-Implantation on the Corrosive-Wear Properties of Surgical Ti-6Al-4V Alloy
Available formats
×
×

Reply to: Submit a response


Your details


Conflicting interests

Do you have any conflicting interests? *