Oxygen Monitor to Study Vascularization of Medical Devices

  • Avid Najdahmadi (a1), Rachel Gurlin (a2), Mellonie Zhang (a2), Jonathan RT Lakey (a2) (a3) and Elliot Botvinick (a1) (a2) (a3)...

Abstract:

Prevascularized medical devices can improve cell therapy. Such devices may replace whole organ transplantation with hosting only the necessary therapeutic cells. We have developed a noninvasive optical technology to study the vascularization into such medical devices. In our technique, oxygen partial pressure within a device is monitored by Oxygen Sensitive Tubes (OSTs), comprising oxygen permeable silicone tubing with inner luminal surfaces coated by an oxygen-sensitive porphyrin dye. OSTs were placed within a PDMS device and transplanted into the subcutaneous space of athymic nude mice. An optical probe placed over the skin excites the OSTs with a pulse of light and detects the luminescent lifetime of emitted light, which is uniquely related to oxygen partial pressure. Furthermore, we developed a Dynamic Inhalation Gas Test (DIGT) to determine the oxygen transport rate between the microvasculature and the device. DIGT works by monitoring oxygen partial pressure in a device following a step change in inhaled-gas oxygen content. We report DIGT oxygen dynamics measured intermittently over eight weeks. Our study shows DIGT dynamics are unique to each implant, supporting the important role of the host tissue response in the availability of oxygen over time.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      Oxygen Monitor to Study Vascularization of Medical Devices
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      Oxygen Monitor to Study Vascularization of Medical Devices
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      Oxygen Monitor to Study Vascularization of Medical Devices
      Available formats
      ×

Copyright

This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.

Corresponding author

Footnotes

Hide All
*

These authors contributed equally

Footnotes

References

Hide All
1Langer, R.S. and Vacanti, J.P., Sci. Am. 280, 86 (1999).
2Yoon, J.-W. and Jun, H.-S., American Journal of Therapeutics 12, 580 (2005).
3Am. J. Ophthalmol. 129, 704 (2000).
4Burke, G.W., Ciancio, G., and Sollinger, H.W., Transplantation 77, S62 (2004).
5Froud, T., Ricordi, C., Baidal, D.A., Hafiz, M.M., Ponte, G., Cure, P., Pileggi, A., Poggioli, R., Ichii, H., Khan, A., Ferreira, J.V., Pugliese, A., Esquenazi, V.V., Kenyon, N.S., and Alejandro, R., Am. J. Transplant 5, 2037 (2005).
6Juang, J.H., Bonner-Weir, S., Ogawa, Y., Vacanti, J.P., and Weir, G.C., Transplantation 61, 1557 (1996).
7Pileggi, A., Molano, R.D., Ricordi, C., Zahr, E., Collins, J., Valdes, R., and Inverardi, L., Transplantation 81, 1318 (2006).
8de Vos, P., Hamel, A.F., and Tatarkiewicz, K., Diabetologia 45, 159 (2002).
9Najdahmadi, A., Lakey, J.R.T., and Botvinick, E., MRS Advances 3, 2399 (2018).
10Lakey, J., Botvinick, E., and Najdahmadi, A., Nanoscale Imaging, Sensing, and Actuation for Biomedical Applications XV (2018).
11de Vos, P., de Vos, P., Spasojevic, M., and Faas, M.M., Advances in Experimental Medicine and Biology 38 (2010).
12Sakata, N., Aoki, T., Yoshimatsu, G., Tsuchiya, H., Hata, T., Katayose, Y., Egawa, S., and Unno, M., Diabetes. Metab. Res. Rev. 30, 1 (2014).
13Hakamivala, A., Huang, Y., Chang, Y., Pan, Z., Nair, A., Hsieh, J., and Tang, L., Advanced Biosystems 3, 1900019 (2019).
14Nojoomi, A., Tamjid, E., Simchi, A., Bonakdar, S., and Stroeve, P., International Journal of Polymeric Materials and Polymeric Biomaterials 66, 105 (2017).
15Pepper, A.R., Pawlick, R., Gala-Lopez, B., MacGillivary, A., Mazzuca, D.M., White, D.J.G., Toleikis, P.M., and James Shapiro, A.M., Transplantation 99, 2294 (2015).
16Phelps, E.A., Templeman, K.L., Thulé, P.M., and García, A.J., Drug Delivery and Translational Research 5, 125 (2015).
17Ratner, B.D., Regen Biomater 3, 107 (2016).
18Gurlin, R.E., Keating, M.T., Li, S., Lakey, J.R., de Feraudy, S., Shergill, B.S., and Botvinick, E.L., J. Tissue Eng. 8, 2041731417691645 (2017).
19Thorson, T.J., Gurlin, R.E., Botvinick, E.L., and Mohraz, A., Acta Biomater. 94, 173 (2019).
20Najdahmadi, A., M Smink, A., de Vos, P., Lakey, J.R.T. and Botvinick, E., Cell Transplantation (2020).
21Tonnesen, M.G., Feng, X., and Clark, R.A.F., Journal of Investigative Dermatology Symposium Proceedings 5, 40 (2000).

Keywords

Related content

Powered by UNSILO

Oxygen Monitor to Study Vascularization of Medical Devices

  • Avid Najdahmadi (a1), Rachel Gurlin (a2), Mellonie Zhang (a2), Jonathan RT Lakey (a2) (a3) and Elliot Botvinick (a1) (a2) (a3)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed.