Hostname: page-component-78c5997874-t5tsf Total loading time: 0 Render date: 2024-11-17T16:36:48.416Z Has data issue: false hasContentIssue false

The Formation of Nano-voids in electroless Cu Layers

Published online by Cambridge University Press:  30 August 2019

T. Bernhard*
Affiliation:
Atotech Deutschland GmbH, Erasmusstrasse 20, 10553Berlin, Germany
S. Branagan
Affiliation:
Atotech USA, 255 Fuller Rd, 12203Albany, USA
R. Schulz
Affiliation:
Atotech Deutschland GmbH, Erasmusstrasse 20, 10553Berlin, Germany
F. Brüning
Affiliation:
Atotech Deutschland GmbH, Erasmusstrasse 20, 10553Berlin, Germany
L. Stamp
Affiliation:
Atotech Deutschland GmbH, Erasmusstrasse 20, 10553Berlin, Germany
K. Wurdinger
Affiliation:
Atotech Deutschland GmbH, Erasmusstrasse 20, 10553Berlin, Germany
S. Kempa
Affiliation:
Atotech Deutschland GmbH, Erasmusstrasse 20, 10553Berlin, Germany
Get access

Abstract

The electrical reliability of multilayer high density interconnection printed circuit boards (HDI-PCBs) is mainly affected by the thermo-mechanical stability of stacked micro via interconnections. Here, a critical failure mode is the stress related crack between the electrolytically filled via and the target pad, commonly known as target pad separation. The junction includes two Cu-Cu-interfaces, one between the target Cu pad and the thin electroless Cu layer and the second between electroless Cu and electrolytic Cu. In this paper we will show that state-of-the-art electroless Cu plating processes are able to provide solid, completely recrystallized and highly reliable stacked via junctions. Defect free interfaces were achieved by using ionic Pd-activators and electroless Cu baths with a cyanide based stabilizer system. Cyanide free electroless Cu baths tend more to the formation of nanometer sized defects, discovered via Transmission Electron Microscopy (TEM). In this case a precise adjustment of single stabilizer components is mandatory to achieve defect free layers. The defects are hollow and were identified as “nano voids”. A critical density of these nano voids weakens the interface, predefines the crack path and reduces the overall reliability of the junction. A precise localization of the nano voids within the junction was enabled by detecting the Ni-containing electroless Cu layer via TEM-Ni mapping. Slower volume exchange of the electroless Cu solution within the blind micro via (BMV) substantially increases the nano void density. The ability of nano voids to migrate and coalesce at elevated temperatures was investigated as well.

Type
Articles
Copyright
Copyright © Materials Research Society 2019 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Heer, H., Wong, R.,” Reliability of stacked microvia”, IPC APEX EXP Conference Proceedings (2015)Google Scholar
Schmidt, R., Beck, T., Rooney, R., Gewirth, A., “Optimization of electrodeposited copper for sub 5 µm L/S redistribution layer lines by plating additives”, IEEE 68th ECTC (2018), https://doi.org/ 101109/ECTC.2018.00188Google Scholar
Nakahara, S., Okinaka, Y., “The Hydrogen Effect in Copper”, Mat. Sci. Eng. A 101, 227-230 (1988), https://doi.org/ 10.1016/0921-5093(88)90069-XCrossRefGoogle Scholar
Graebner, J.E., Okinaka, Y,” Molecular hydrogen in electroless copper deposits”, J. Appl. Phys. 60, 36-39 (1986), https://doi.org/ 10.1063/1.337656CrossRefGoogle Scholar
Vaskelis, A., Juskenas, R., Jaciauskiene, J., “Copper hydride formation in the electroless copper plating process: in situ X-ray diffraction evidence and electrochemical study”, Electrochemica Acta, Vol. 43, 9, 1061-1066 (1998), https://doi.org/10.1016/S0013-4686(97)00282-XCrossRefGoogle Scholar
Sharma, T. et al., “Nickel dependence of hydrogen generation, hydrogen co-deposition and film stress in an electroless copper process”, Thin solid films, Vol. 666,9, 76-84 (2018), https://doi.org/101016/j.tsf.2018.09.029CrossRefGoogle Scholar
Bernhard, T. et al., “Main impact factors on internal stress of electroless deposited copper films”, IMAPS Fall conference, Vol. 2015, 99-104 (2015), https://doi.org/10.4071/isom-2015-TP42Google Scholar
Nakahra, S. et al., “Microscopic mechanism of the hydrogen effect on the ductility of electroless copper”, Acta Metallurgica, Vol. 36, 7, 1669-1681, (1988), https://doi.org/10.1016/0001-6160(88)90234-9CrossRefGoogle Scholar
Zeng, K., Williamson, J.M., “Improve interconnect reliability of BGA substrate with stacked vias by reducing carbon inclusion in the interface between via and land pad”, IEEE 68th ECTC (2018), https://doi.org/10.1109/ECTC.2018.00031Google Scholar
Lakoubovskii, K., Mitsuishi, K., Nakayama, Y., Furuya, K., “Thickness measurements with electron energy loss spectroscopy”, Microscopy Research and Technique, vol. 71, 8, 626-631, (2008), https://doi.org/10.1002/jemt.20597CrossRefGoogle Scholar
Clement, L. et al., “Strain measurements by convergent-beam electron diffraction: The importance of stress relaxation in lamella preparations”, Appl. Phys. Lett. 85, 651 (2004), https://doi.org/10.1063/1.1774275CrossRefGoogle Scholar
IPC-standard: IPC-TM-650 2.6.27AGoogle Scholar
Bernhard, T., Gregoriades, L., “Nanovoid Formation at Cu/Cu/Cu Interconnections of Blind Microvias: A Field Study”, will be published at IMAPS Conference Proceedings (2019)Google Scholar