Hostname: page-component-848d4c4894-r5zm4 Total loading time: 0 Render date: 2024-06-18T16:30:01.751Z Has data issue: false hasContentIssue false

X-Ray Microanalysis of Human Erythrocytes Artificially Jetted Through Tubes At Different Pressures by “in vitro Cryotechnique”

Published online by Cambridge University Press:  02 July 2020

Y. Fujii
Affiliation:
Department of Anatomy, Yamanashi Medical University, 1110 Shimokato, Tamaho, Yamanashi, 409-3898, Japan
N. Terada
Affiliation:
Department of Anatomy, Yamanashi Medical University, 1110 Shimokato, Tamaho, Yamanashi, 409-3898, Japan
T. Baba
Affiliation:
Department of Anatomy, Yamanashi Medical University, 1110 Shimokato, Tamaho, Yamanashi, 409-3898, Japan
H. Ueda
Affiliation:
Department of Anatomy, Yamanashi Medical University, 1110 Shimokato, Tamaho, Yamanashi, 409-3898, Japan
S. Ohno
Affiliation:
Department of Anatomy, Yamanashi Medical University, 1110 Shimokato, Tamaho, Yamanashi, 409-3898, Japan
Get access

Abstract

It is well known that flowing erythrocytes in blood capillaries were morphologically changing in vivo, as observed by light microscopy. Recently, dynamic morphological changes of flowing mouse erythrocytes in large blood vessels and hepatic sinusoids were demonstrated by scanning (SEM) or transmission (TEM) electron microscopy with our “in vivo cryotechnique”. Moreover, human erythrocyte deformability was already studied under artificially jetting conditions at different pressures by using “in vivo cryotechnique”, followed by freeze-substitution method for SEM. in this study, we have analyzed elemental changes of each human erythrocyte at different jetting pressures by “in vivo cryotechnique” combined with SEM for X-ray microanalysis.

Human blood was collected with heparin-coated syringes, divided into two groups and kept at 4°C and 36°C. They were directly jetted into isopentane-propane cryogen (-193°C) through tubes (21 gauge) at different pressures (0-220mmHg) (Fig.la). The frozen blood samples were freeze-dried (4-6×10-7torr,-95°C,24h) in Eiko FD-3AS apparatus (Eiko Engineering, Japan) (Fig. lb).

Type
Cryoimmobilization, Freeze Substitution and Cryoem (Organized by S. Erlandsen)
Copyright
Copyright © Microscopy Society of America 2001

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Xue, M. et al.,J. Anat, 193(1998)73.CrossRefGoogle Scholar
2.Terada, N. et al.,J. Electron Micros., 47(1998)67.Google Scholar
3.Terada, N. et al.,J. Electron Micros., 47(1998)489.CrossRefGoogle Scholar