Skip to main content Accessibility help
×
Home

Cryomesh™: A New Substrate for Cryo-Electron Microscopy

  • Craig Yoshioka (a1), Bridget Carragher (a1) and Clinton S. Potter (a1)

Abstract

Here we evaluate a new grid substrate developed by ProtoChips Inc. (Raleigh, NC) for cryo-transmission electron microscopy. The new grids are fabricated from doped silicon carbide using processes adapted from the semiconductor industry. A major motivating purpose in the development of these grids was to increase the low-temperature conductivity of the substrate, a characteristic that is thought to affect the appearance of beam-induced movement (BIM) in transmission electron microscope (TEM) images of biological specimens. BIM degrades the quality of data and is especially severe when frozen biological specimens are tilted in the microscope. Our results show that this new substrate does indeed have a significant impact on reducing the appearance and severity of beam-induced movement in TEM images of tilted cryo-preserved samples. Furthermore, while we have not been able to ascertain the exact causes underlying the BIM phenomenon, we have evidence that the rigidity and flatness of these grids may play a major role in its reduction. This improvement in the reliability of imaging at tilt has a significant impact on using data collection methods such as random conical tilt or orthogonal tilt reconstruction with cryo-preserved samples. Reduction in BIM also has the potential for improving the resolution of three-dimensional cryo-reconstructions in general.

Copyright

Corresponding author

Corresponding author. E-mail: cpotter@scripps.edu

References

Hide All
Booy, F.P. & Pawley, J.B. (1993). Cryo-crinkling: What happens to carbon films on copper grids at low temperature. Ultramicroscopy 48, 273280.
Bottcher, B. (1995). Electron cryo-microscopy of graphite in amorphous ice. Ultramicroscopy 58, 417424.
Brink, J., Sherman, M.B., Berriman, J. & Chiu, W. (1998). Evaluation of charging on macromolecules in electron cryomicroscopy. Ultramicroscopy 72, 4152.
Chen, J.Z., Sachse, C., Xu, C., Mielke, T., Spahn, C.M. & Grigorieff, N. (2008). A dose-rate effect in single-particle electron microscopy. J Struct Biol 161, 92100.
Downing, K., Sui, H. & Auer, M. (2007). Electron tomography: A 3D view of the subcellular world. Anal Chem 79, 79497957.
Dubochet, J. & Lepault, J. (1984). Cryo-electron microscopy of vitrified water. J Phys Colloques 45, 8494.
Glaeser, R.M. (1985). Electron crystallography of biological macromolecules. Ann Rev Phys Chem 36, 243275.
Glaeser, R.M. (2008). Retrospective: Radiation damage and its associated information limitations. J Struct Biol 163, 271276.
Glaeser, R.M. & Downing, K. (2004). Specimen charging on thin films with one conducting layer: Discussion of physical principles. Microsc Microanal 10, 790796.
Gyobu, N., Tani, K., Hiroaki, Y., Kamegawa, A., Mitsuoka, K. & Fujiyoshi, Y. (2004). Improved specimen preparation for cryo-electron microscopy using a symmetric carbon sandwich technique. J Struct Biol 146, 325333.
Henderson, R. (1992). Image contrast in high-resolution electron microscopy of biological macromolecules: TMV in ice. Ultramicroscopy 46, 118.
Henderson, R. & Glaeser, R.M. (1985). Quantitative analysis of image contrast in electron micrographs of beam-sensitive crystals. Ultramicroscopy 16, 139150.
Lander, G.C., Khayat, R., Li, R., Prevelige, P.E., Potter, C.S., Carragher, B. & Johnson, J.E. (2009). The P22 tail machine at subnanometer resolution reveals the architecture of an infection conduit. Structure 17, 789799.
Leschziner, A.E. & Nogales, E. (2006). The orthogonal tilt reconstruction method: An approach to generating single-class volumes with no missing cone for ab initio reconstruction of asymmetric particles. J Struct Biol 153, 284299.
Radermacher, M. (1988). Three-dimensional reconstruction of single particles from random and nonrandom tilt series. J Elec Microsc Tech 9, 359394.
Rhinow, D. & Kühlbrandt, W. (2008). Electron cryo-microscopy of biological specimens on conductive titanium-silicon metal glass films. Ultramicroscopy 108, 698705.
Stagg, S.M., Lander, G.C., Quispe, J., Voss, N.R., Cheng, A., Bradlow, H., Bradlow, S., Carragher, B. & Potter, C.S. (2008). A test-bed for optimizing high-resolution single particle reconstructions. J Struct Biol 163, 2939.
Suloway, C., Pulokas, J., Fellmann, D., Cheng, A., Guerra, F., Quispe, J., Stagg, S., Potter, C.S. & Carragher, B. (2005). Automated molecular microscopy: The new Leginon system. J Struct Biol 151, 4160.
Vonck, J. (2000). Parameters affecting specimen flatness of two-dimensional crystals for electron crystallography. Ultramicroscopy 85, 123129.
Yoshioka, C., Pulokas, J., Fellmann, D., Potter, C.S., Milligan, R.A. & Carragher, B. (2007). Automation of random conical tilt and orthogonal tilt data collection using feature-based correlation. J Struct Biol 159, 335346.

Keywords

Metrics

Altmetric attention score

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed