Skip to main content Accessibility help
×
Home

Atomic Force Microscopy (AFM) Analysis of an Object Larger and Sharper than the AFM Tip

  • Zhe Chen (a1) (a2), Jiawei Luo (a1) (a2), Ivo Doudevski (a2), Sema Erten (a2) and Seong H. Kim (a1) (a2)...

Abstract

Atomic force microscopy (AFM) is typically used for analysis of relatively flat surfaces with topographic features smaller than the height of the AFM tip. On flat surfaces, it is relatively easy to find the object of interest and deconvolute imaging artifacts resulting from the finite size of the AFM tip. In contrast, AFM imaging of three-dimensional objects much larger than the AFM tip height is rarely attempted although it could provide topographic information that is not readily available from two-dimensional imaging, such as scanning electron microscopy. In this paper, we report AFM measurements of a vertically-mounted razor blade, which is taller and sharper than the AFM tip. In this case, the AFM height data, except for the data collected around the cutting edge of the blade, reflect the shape of the AFM tip. The height data around the apex area are effectively the convolution of the AFM tip and the blade cutting edge. Based on computer simulations mimicking an AFM tip scanning across a round sample, a simple algorithm is proposed to deconvolute the AFM height data of an object taller and sharper than the AFM tip and estimate its effective curvature.

Copyright

Corresponding author

*Author for correspondence: Seong H. Kim, E-mail: shkim@engr.psu.edu

References

Hide All
Allen, MJ, Hud, NV, Balooch, M, Tench, RJ, Siekhaus, WJ & Balhorn, R (1992). Tip-radius-induced artifacts in AFM images of protamine-complexed DNA fibers. Ultramicroscopy 42-44, 10951100.
Atamny, F & Baiker, A (1995). Direct imaging of the tip shape by AFM. Surf Sci 323(3), L314L318.
Binnig, G, Quate, CF & Gerber, C (1986). Atomic force microscope. Phys Rev Lett 56(9), 930933.
Dongmo, LS, Villarrubia, JS, Jones, SN, Renegar, TB, Postek, MT & Song, JF (2000). Experimental test of blind tip reconstruction for scanning probe microscopy. Ultramicroscopy 85(3), 141153.
Flater, EE, Zacharakis-Jutz, GE, Dumba, BG, White, IA & Clifford, CA (2014). Towards easy and reliable AFM tip shape determination using blind tip reconstruction. Ultramicroscopy 146, 130143.
Gołek, F, Mazur, P, Ryszka, Z & Zuber, S (2014). AFM image artifacts. Appl Surf Sci 304, 1119.
Hübner, U, Morgenroth, W, Meyer, HG, Sulzbach, T, Brendel, B & Mirandé, W (2003). Downwards to metrology in nanoscale: Determination of the AFM tip shape with well-known sharp-edged calibration structures. Appl Phys A 76(6), 913917.
Josep, C-F, Eugenio, C, Alicia, F-A & Elena, P-C (2014). Correction of the tip convolution effects in the imaging of nanostructures studied through scanning force microscopy. Nanotechnology 25(39), 395703.
Keller, D (1991). Reconstruction of STM and AFM images distorted by finite-size tips. Surf Sci 253(1), 353364.
Kondratov, AV, Rogov, OY & Gainutdinov, RV (2017). AFM reconstruction of complex-shaped chiral plasmonic nanostructures. Ultramicroscopy 181, 8185.
Lui, CH, Liu, L, Mak, KF, Flynn, GW & Heinz, TF (2009). Ultraflat graphene. Nature 462, 339341.
Montelius, L & Tegenfeldt, JO (1993). Direct observation of the tip shape in scanning probe microscopy. Appl Phys Lett 62 (21), 26282630.
Reiss, G, Schneider, F, Vancea, J & Hoffmann, H (1990). Scanning tunneling microscopy on rough surfaces: Deconvolution of constant current images. Appl Phys Lett 57(9), 867869.
Ricci, D & Braga, PC (2004). Recognizing and avoiding artifacts in AFM imaging. In Atomic Force Microscopy: Biomedical Methods and Applications, Braga, PC & Ricci, D (Eds.), pp. 2537. Totowa, New Jersey: Humana Press.
Scienceofsharp (2015). The pasted strop – Part 3. Available at https://scienceofsharp.wordpress.com/2015/03/31/the-pasted-strop-part-3/ (retrieved May 05, 2019).
Severin, N, Dorn, M, Kalachev, A & Rabe, JP (2011). Replication of single macromolecules with graphene. Nano Lett 11(6), 24362439.
Shen, J, Zhang, D, Zhang, F-H & Gan, Y (2017). AFM tip-sample convolution effects for cylinder protrusions. Appl Surf Sci 422, 482491.
Tranchida, D, Piccarolo, S & Deblieck, RAC (2006). Some experimental issues of AFM tip blind estimation: The effect of noise and resolution. Meas Sci Technol 17(10), 26302636.
Villarrubia, JS (1994). Morphological estimation of tip geometry for scanned probe microscopy. Surf Sci 321(3), 287300.
Villarrubia, JS (1997). Algorithms for scanned probe microscope image simulation, surface reconstruction, and tip estimation. J Res Natl Inst Stand Technol 102(4), 425454.
Winzer, AT, Kraft, C, Bhushan, S, Stepanenko, V & Tessmer, I (2012). Correcting for AFM tip induced topography convolutions in protein–DNA samples. Ultramicroscopy 121, 815.

Keywords

Atomic Force Microscopy (AFM) Analysis of an Object Larger and Sharper than the AFM Tip

  • Zhe Chen (a1) (a2), Jiawei Luo (a1) (a2), Ivo Doudevski (a2), Sema Erten (a2) and Seong H. Kim (a1) (a2)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed