Evaluation of plan optimisers in prostate VMAT using the dose distribution index

  • James C. L. Chow (a1) (a2), Runqing Jiang (a3) (a4) and Lu Xu (a3) (a4)

Abstract:

Purpose:

Dose distribution index (DDI) is a treatment planning evaluation parameter, reflecting dosimetric information of target coverage that can help to spare organs at risk (OARs) and remaining volume at risk (RVR). The index has been used to evaluate and compare prostate volumetric modulated arc therapy (VMAT) plans using two different plan optimisers, namely photon optimisation (PO) and its predecessor, progressive resolution optimisation (PRO).

Materials and methods:

Twenty prostate VMAT treatment plans were created using the PO and PRO in this retrospective study. The 6 MV photon beams and a dose prescription of 78 Gy/39 fractions were used in plans with the same dose–volume criteria for plan optimisation. Dose–volume histograms (DVHs) of the planning target volume (PTV), as well as of OARs such as the rectum, bladder, left and right femur were determined in each plan. DDIs were calculated and compared for plans created by the PO and PRO based on DVHs of the PTV and all OARs.

Results:

The mean DDI values were 0·784 and 0·810 for prostate VMAT plans created by the PO and PRO, respectively. It was found that the DDI of the PRO plan was about 3·3% larger than the PO plan, which means that the dose distribution of the target coverage and sparing of OARs in the PRO plan was slightly better. Changing the weighting factors in different OARs would vary the DDI value by ∼7%. However, for plan comparison based on the same set of dose–volume criteria, the effect of weighting factor can be neglected because they were the same in the PO and PRO.

Conclusions:

Based on the very similar DDI values calculated from the PO and PRO plans, with the DDI value in the PRO plan slightly larger than that of the PO, it may be concluded that the PRO can create a prostate VMAT plan with slightly better dose distribution regarding the target coverage and sparing of OARs. Moreover, we found that the DDI is a simple and comprehensive dose–volume parameter for plan evaluation considering the target, OARs and RVR.

Copyright

Corresponding author

Author for correspondence: Dr James Chow, Department of Medical Physics, Princess Margaret Cancer Centre/UHN, 7/F, 700 University Avenue, Toronto, ON, Canada M5G 1X6. Tel: 416 946 4501. Fax: 416 946 6566. E-mail: james.chow@rmp.uhn.ca

References

Hide All
1. Fraass, B, Doppke, K, Hunt, M et al. American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning. Med Phys 1998; 25 (10): 17731829.
2. Malicki, J. The importance of accurate treatment planning, delivery, and dose verification. Rep Pract Oncol Radiother 2012; 17 (2): 6365.
3. Smilowitz, J B, Das, I J, Feygelman, V et al. AAPM medical physics practice guideline 5. a.: commissioning and QA of treatment planning dose calculations—megavoltage photon and electron beams. J App Clin Med Phys 2015; 16 (5): 1434.
4. Feuvret, L, Noël, G, Mazeron, J J, Bey, P. Conformity index: a review. Int J Radiat Oncol Biol Phys 2006; 64 (2): 333342.
5. Yoon, M, Park, SY, Shin, D et al. A new homogeneity index based on statistical analysis of the dose–volume histogram. J App Clin Med Phys 2007; 8 (2): 917.
6. Wagner, T H, Bova, F J, Friedman, W A, Buatti, J M, Bouchet, L G, Meeks, S L. A simple and reliable index for scoring rival stereotactic radiosurgery plans. Int J Radiat Oncol Biol Phys 2003; 57 (4): 11411149.
7. Chow, J C L, Jiang, R, Markel, D. Variation of PTV dose distribution on patient size in prostate VMAT and IMRT: a dosimetric evaluation using the PTV dose–volume factor. J Radiother Pract 2014; 13 (2): 189194.
8. Chow, J C L, Jiang, R, Kiciak, A, Markel, D. Dosimetric comparison between the prostate intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans using the planning target volume (PTV) dose–volume factor. J Radiother Pract 2016; 15 (3): 263268.
9. Webb, S, Nahum, A E. A model for calculating tumour control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic cell density. Phys Med Biol 1993; 38 (6): 653666.
10. Kutcher, G J, Burman, C. Calculation of complication probability factors for non-uniform normal tissue irradiation: the effective volume method gerald. Int J Radiat Oncol Biol Phys 1989; 16 (6): 16231630.
11. Niemierko, A. Reporting and analyzing dose distributions: a concept of equivalent uniform dose. Med Phys 1997; 24 (1): 103110.
12. Warkentin, B, Stavrev, P, Stavreva, N, Field, C, Fallone, B G. A TCP-NTCP estimation module using DVHs and known radiobiological models and parameter sets. J App Clin Med Phys 2004; 5 (1): 5063.
13. Paudel, N R, Narayanasamy, G, Han, E Y et al. Dosimetric and radiobiological comparison for quality assurance of IMRT and VMAT plans. J App Clin Med Phys 2017; 18 (5): 237244.
14. Isa, M, Jiang, R, Kiciak, A, Rehman, J, Afzal, M, Chow J C L. Dosimetric and radiobiological characterizations of prostate IMRT and VMAT: a single-institution review of 90 cases. J Med Phys 2016; 41: 162168.
15. Alfonso, J C, Herrero, M A, Nunez, L. A dose-volume histogram based decision-support system for dosimetric comparison of radiotherapy treatment plans. Radiat Oncol 2015; 10 (1): 263.
16. Chow, J C L, Jiang, R, Kiciak, A. Dose-volume consistency and radiobiological characterization between prostate IMRT and VMAT plans. Int J Cancer Ther Oncol 2016; 4: 447.
17. Quan, EM, Li, X, Li, Y et al. A comprehensive comparison of IMRT and VMAT plan quality for prostate cancer treatment. Int J Radiat Oncol Biol Phys 2012; 83 (4): 11691178.
18. Davidson, M T, Blake, S J, Batchelar, D L, Cheung, P, Mah, K. Assessing the role of volumetric modulated arc therapy (VMAT) relative to IMRT and helical tomotherapy in the management of localized, locally advanced, and post-operative prostate cancer. Int J Radiat Oncol Biol Phys 2011; 80 (5): 15501558.
19. EclipseTM Photon and Electron Reference Guide. Document ID P1015026-001-A ed. Palo Alto, CA, USA: Varian Medical Systems Inc.; 2015. p. 343.
20. Liu, H, Sintay, B, Pearman, K et al. Comparison of the progressive resolution optimizer and photon optimizer in VMAT optimization for stereotactic treatments. J Appl Clin Med Phys 2018; 19: 155162.
21. Binny, D, Kairn, T, Lancaster, C M, Trapp, J V, Crowe, S B. Photon optimizer (PO) vs progressive resolution optimizer (PRO): a conformality-and complexity-based comparison for intensity-modulated arc therapy plans. Med Dosim 2018; 43 (3): 267275.
22. Jiang, F, Wu, H, Yue, H, Jia, F, Zhang, Y. Photon Optimizer (PO) prevails over Progressive Resolution Optimizer (PRO) for VMAT planning with or without knowledge-based solution. J Appl Clin Med Phys 2017; 18 (2): 914.
23. Chow, J C L, Jiang, R. Prostate volumetric-modulated arc therapy: dosimetry and radiobiological model variation between the single-arc and double-arc technique. J Appl Clin Med Phys 2013; 14: 312.
24. Bentzen, S M, Constine, L S, Deasy, J O et al. Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): an introduction to the scientific issues. Int J Radiat Oncol Biol Phys 2010; 76 (3): S3S9.
25. Li, G, Zhang, Y, Jiang, X et al. Evaluation of the ArcCHECK QA system for IMRT and VMAT verification. Phys Med 2013; 29 (3): 295303.
26. Neilson, C, Klein, M, Barnett, R, Yartsev, S. Delivery quality assurance with ArcCHECK. Med Dosim 2013; 38 (1): 7780.
27. Chow, J C L. Internet-based computer technology on radiotherapy. Rep Pract Oncol Radiother 2017; 22: 455462.