Abstract

A multi-cross-correlation method (MCCM) was developed in a particle image velocimetry (PIV) auto-processing system to reduce spurious vectors and improve accuracy of measurements. This technique is an improvement based on conventional cross-correlation method (CCM). Four typical neighboring interrogation windows were specified to be overlapped and calculated by MCCM. A high cross-correlation value is obtained in which many particle images match up with their corresponding spatially shifted partners, and small cross-correlation peaks due to interference of noises during experiments are reduced. Several parameters such as out-of-plane motions, particle size, and seeding density are considered for checking both MCCM and conventional PIV algorithms. The examination gives authenticity to the merits of MCCM for avoiding particles loss or mistaken velocity vectors.

Copyright

Corresponding author

*Professor, corresponding author

References

Hide All
1. Raffel, M, Willert, C, and Kompenhans, J, “Particle Image Velocimetry, a Practical Guide,” Springer, Berlin Heidelberg New York (1998).
2. Grue, J, Liu, P, and Pedersen, G, “PIV and Water Waves,” Advances in Coastal and Ocean Engineering, 9, World Scientific, Hackensack N.J. London, 352p (2004).
3. Chang, K, and Liu, P, “Pseudo Turbulence in PIV Breaking-Wave Measurements,” Experiments in Fluids, 29, pp. 331338 (2000).
4. Chang, K, Hsu, T, and Liu, P, “Vortex Generation and Evolution in Water Waves Propagating Over a Submerged Rectangular Obstacle, Part II: Cnoidal Waves,” Coastal Engineering, 52, pp. 257283 (2005).
5. Keane, R, and Adrain, R, “Optimization of Particle Image Velocimetry, Part I: Double Pulsed Systems,” Measurement Science and Technology, 1, pp. 12021215 (1990).
6. Raffel, M, and Kompenhans, J, “Theoretical and Experimental Aspects of Image-Shifting by Means of a Rotating Mirror System for Particle Image Velocimetry,” Measurement Science and Technology, 6, pp. 795808 (1995).
7. Dracos, T, “Three-Dimensional Velocity and Vorticity Measuring and Image Analysis Techniques,” Springer, Berlin Heidelberg New York (1996).
8. Shavit, U, Lowe, R. J. and Steinbuck, J. V., “Intensity Capping: A Simple Method to Improve Cross-Correlation PIV Results,” Experiments in Fluids, 42, pp. 225240 (2007).
9. Keane, R, and Adrain, R, “Theory of Cross-Correlation Analysis of PIV Images,” Applied Scientific Research, 49, pp. 191215 (1992).
10. Willert, C, and Gharib, M, “Digital Particle Image Velocimetry,” Experiments in Fluids, 10, pp. 181193 (1991).
11. Huang, H, Dabiri, D, and Gharib, M, “On Errors of Digital Particle Image Velocimetry,” Measurement Science and Technology, 8, pp. 14271440 (1997).
12. Westerweel, J, “Efficient Detection of Spurious Vectors in Particle Image Velocimetry Data,” Experiments in Fluids, 16, pp. 236247 (1994).
13. Huang, H, Fiedler, H, and Wang, J, “Limitation and Improvement of PIV, Part I: Limitation of Conventional Techniques Due to Deformation of Particle Image Patterns,” Experiments in Fluids, 15, pp. 168174 (1993a).
14. Huang, H, Fiedler, H, and Wang, J, “Limitation and Improvement of PIV, Part II: Particle Image Distortion, a Novel Technique,” Experiments in Fluids, 15, pp. 263273 (1993b).
15. Veber, P, Dahl, J, and Hermansson, R, “Study of the Phenomena Affecting the Accuracy of a Video-Based Particle Tracking Velocimetry Technique,” Experiments in Fluids, 22, pp. 482488 (1997).
16. Yamamoto, F, Wada, A, Iguchi, M, and Ishikawa, M, “Visualization and Image Processing of Torque Converter Internal Flow,” Journal of Flow Visualization Image Proceedings, 3, pp. 5164 (1996).
17. Nogueira, J, Lecunoa, A, and Rodriguez, P, “Data Validation, False Vectors Correction and Derived Magnitudes Calculation on PIV Data,” Measurement Science and Technology, 8, pp. 14931501 (1997).
18. Falchi, M, Querzoli, G, and Romano, G. P., “Robust Evaluation of the Dissimilarity Between Interrogation Windows in Image Velocimetry,” Experiments in Fluids, 41, pp. 279293 (2006).
19. Brevis, W, Nino, Y, and Jirka, G. H, “Integrating Cross- Correlation and Relaxation Algorithms for Particle Tracking Velocimetry,” Experiments in Fluids, DOI 10.1007/S00348-010-0907-Z. (2010).
20. Hart, D. P., “PIV Error Correction,” Experiments in Fluids, 29, pp. 1322 (2000).
21. Westerweel, J, Digital Particle Image Velocimetry-Theory and Application, PhD Dissertation, Delft University Press, Delft, The Netherlands (1993).
22. Keane, R, Adrian, R, and Zhang, Y, “Super-Resolution Particle Image Velocimetry,” Measurement Science and Technology, 6, pp. 754768 (1995).
23. Cowen, E, and Monismith, S, “A Hybrid Digital Particle Tracking Velocimetry Technique,” Experiments in Fluids, 22, pp. 199211 (1997).

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed