Hostname: page-component-77c89778f8-7drxs Total loading time: 0 Render date: 2024-07-20T22:04:18.688Z Has data issue: false hasContentIssue false

Branula used as T-tube introducer for middle-ear effusion

Published online by Cambridge University Press:  26 November 2007

R Raman*
Affiliation:
Department of Otorhinolaryngology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
O Rahmat
Affiliation:
Department of Otorhinolaryngology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia
*
Address for correspondence: Professor R Raman, Dept of Otorhinolaryngology, Faculty of Medicine, University Malaya, 50603, Kuala Lumpur, Malaysia. Fax: 006079556963 E-mail: ramanr_99@yahoo.com

Abstract

Objective:

We report a method of inserting a T-tube.

Method:

A 14-G branula and a T-tube are used.

Results:

This method was found to be simple and required few instruments.

Conclusions:

To the best of our knowledge, this method has not previously been reported.

Type
Short Communication
Copyright
Copyright © JLO (1984) Limited 2007

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1 Charlette, SD, Anari, S. Tympanotomy T-tube introducer: a simple technique using a Zoellner suction tube. Laryngoscope 2007:117;563CrossRefGoogle Scholar