2118 Solid-state MRI as a nonradiative alternative to computed tomography for craniofacial imaging

  • Rosaline Zhang (a1), Hyunyeol Lee (a2), Xia Zhao (a2), Hee K. Song (a2), Felix W. Wehrli (a2) and Scott P. Bartlett (a3)...

Abstract

OBJECTIVES/SPECIFIC AIMS: Computed tomography (CT) enables 3-dimensional (3D) visualization of cortical bone structures with high spatial resolution, and thus has been the gold-standard method for evaluation and diagnosis of craniofacial skeletal pathologies. However, ionizing radiation and, in particular, repeated scanning for presurgery and postsurgery assessments, is of concern when applied to infants and young children. Recent advances in solid-state MRI allow the capture of the short-T2 signals in cortical bone while suppressing the signal from soft-tissue protons having T2 relaxation time 1–2 orders of magnitude longer (50–100 ms). One approach, a dual-radiofrequency (RF) pulse and ultrashort echo time (UTE) imaging based method, exploits different sensitivities of bone and soft tissue to different RF pulse widths and TEs. This study aims to demonstrate the feasibility of producing 3D renderings of the human skull and visualization of cranial sutures using the bone-selective MRI technique in comparison to CT. METHODS/STUDY POPULATION: Imaging technique: Two RF pulses differing in duration and amplitude are alternately applied in successive repetition time (TR) along the pulse train. Within each TR, 2 echoes are acquired. Acquisition of the first echo starts at the ramp-up of the encoding gradient (TE1), allowing for capture of signals with very short lifetimes (bone), while that of the second starts after a longer delay (TE2). In total, 4 echoes are obtained: ECHO11 (RF1TE1), ECHO12 (RF1TE2), ECHO21 (RF2TE1), and ECHO22 (RF2TE2). During reconstruction, ECHO11 is combined with ECHO21 and ECHO12 is combined with ECHO22, resulting in 2 images. The subtraction of these 2 images yields an enhanced bone contrast. Data acquisition/processing: The pulse sequence described above was applied for MR imaging of a human cadaveric skull and 2 adult human subjects in vivo, at 3T field strength (Siemens Prisma, Erlangen, Germany). Imaging parameters: TR/TE1/TE2=7/0.06/2.46 ms, RF1/RF2 durations=40/520 μs, flip angle=12°, matrix size=2563, field of view=2803 mm3, voxel size=1.1 mm isotropic, number of radial spokes=25,000, and scan time=6 minutes. Segmentation of bone voxels was performed using ITK-SNAP in a semi-automatic fashion, leading to 3D renderings of the skull. For comparison, a CT scan was also performed in the human cadaveric skull with 1 mm isotropic resolution. Validation: The biometric accuracy was assessed by measuring eight anatomic distances: (1) Maximum craniocaudal aperture of the right orbit. (2) Maximum craniocaudal aperture of the left orbit. (3) Maximum height of the mandible from chin point in the midline. (4) Maximum cranial length (5) Maximum cranial width. (6) Maximum height of piriform aperture. (7) Distance between lateral most aspect of mandibular condyles. (8) Distance between lateral most aspect of posterior hard palate in both CT- and MRI-based 3D renderings of the human cadaveric skull using Mimics software (Materialise®, Ghent, Belgium). These distances were compared with those directly measured on the cadaveric skull. RESULTS/ANTICIPATED RESULTS: Compares CT with the proposed MRI method on cadaveric human skull images, along with corresponding 3D renderings. Compared with CT, the 3D rendered images maintain most features over the entire head (e.g., zygomatic arch), except for appearance of some artifacts in the mandibular region. In vivo head images in 2 adult subjects: axial magnitude images and 3D rendering. In the axial images, bone voxels as well as the inner table of the cranium are clearly visualized, and cranial and spinal bone structures are well depicted in the 3D renderings. Some voxels were erroneously included or excluded in the renderings. The mean difference in measurements of the 8 anatomic distances was 6, 4, and 2 mm when comparing MRI Versus CT, MRI Versus in situ, and CT Versus in situ, respectively. DISCUSSION/SIGNIFICANCE OF IMPACT: Bone proton magnetization exhibits a substantial level of signal decay during the relatively long duration of RF2 due to its very short T2 relaxation time. In contrast, soft-tissue retains nearly the same level of signal intensities over all echoes. Thus, subtraction of ECHO22 from ECHO11, when compared with the difference between ECHO11 and ECHO12, enhances bone contrast from soft tissue. The proposed, dual-RF dual-echo 3D UTE imaging technique produces isotropic high-resolution bone-specified images in the whole head within a clinically feasible imaging time (6 min), leading to clear visualization of craniofacial skeletal structures. These are key components necessary for translation to the clinical setting. Optimization of postprocessing for more realistic 3D renderings and thus accurate anatomic measurements is currently being implemented. The proposed method’s potential as a nonradiative alternative to CT will then be thoroughly evaluated in pediatric patients.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      2118 Solid-state MRI as a nonradiative alternative to computed tomography for craniofacial imaging
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      2118 Solid-state MRI as a nonradiative alternative to computed tomography for craniofacial imaging
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      2118 Solid-state MRI as a nonradiative alternative to computed tomography for craniofacial imaging
      Available formats
      ×

Copyright

This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed