Evaluation of the Sterility and Stability of Insulin from Multidose Vials Used for Prolonged Periods

Published online by Cambridge University Press:  02 January 2015

Minaxi Rathod
Affiliation:
University of Michigan Medical School, the Division of Infectious Disease and Hospital Epidemiology, and the Division of Metabolic Diseases, Henry Ford Hospital, Detroit, Michigan
Louis Saravolatz*
Affiliation:
University of Michigan Medical School, the Division of Infectious Disease and Hospital Epidemiology, and the Division of Metabolic Diseases, Henry Ford Hospital, Detroit, Michigan
Donald Pohlod
Affiliation:
University of Michigan Medical School, the Division of Infectious Disease and Hospital Epidemiology, and the Division of Metabolic Diseases, Henry Ford Hospital, Detroit, Michigan
Fred Whitehouse
Affiliation:
University of Michigan Medical School, the Division of Infectious Disease and Hospital Epidemiology, and the Division of Metabolic Diseases, Henry Ford Hospital, Detroit, Michigan
Jose Goldman
Affiliation:
University of Michigan Medical School, the Division of Infectious Disease and Hospital Epidemiology, and the Division of Metabolic Diseases, Henry Ford Hospital, Detroit, Michigan
*
Division of Infectious Disease and Hospital Epidemiology, Henry Ford Hospital, 2799 West Grand Boulevard, Detroit, Ml 48202

Abstract

Diabetic patients frequently use their insulin vials for prolonged periods, even though antibacterial preservatives used in multidose insulin vials are not required to be effective beyond 28 days. For this reason, we evaluated the antibacterial activity present in multidose insulin vials for up to 50 days. Multidose lente insulin vials were inoculated with S. aureus and P. aeruginosa. Vials incubated at room temperature (21°C) were sterile by 48 hours, whereas when they were incubated at refrigerator temperatures (4°C), S. aureus contamination persisted up to the 17th day and P. aeruginosa were killed after 10 days. The same vials were serially contaminated on days 17, 30, and 50, and a similar antibacterial effect was maintained. Sixty-nine multidose insulin vials used for an average of 53 days were cultured. Eight vials demonstrated bacterial contamination with 1 cfu/ml of S. epidermidis or Propionibacterium acnes. No endotoxin was detected in the multidose vials used for more than 28 days. Insulin assays on 40 multidose insulin vials used for more than 28 days showed an average insulin content of 101.6±1.9 units/ml. This study did not demonstrate significant bacterial contamination, endotoxin activity, or insulin degradation of multidose insulin in vials used for periods longer than 28 days. In addition, antibacterial preservatives were more effective at room temperature than at refrigerator temperature; thus, the practice of patients not refrigerating insulin vials is sensible.

Type
Original Articles
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1985

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Schade, DS, Eaton, R: Bactericidal properties of commercial USP-formulated insulin. Diabetes 1982; 31:3639.Google Scholar
2.Longfield, R, Longfield, J, Smith, LP. et al: Multidose medication vial sterility: An in-use study and a review of the literature. Infect Control 1984; 5:165169.Google Scholar
3.Rosenzweig, AL: Potential health hazards in the multiple dose vial. Journal of the American Hospital Association 1964; 38:7174.Google Scholar
4.Anon, : The United States Pharmacopeia, 19th rev., The United States Pharmacopeia Convention, Inc., Rockville, Maryland, 1975; 587588.Google Scholar
5.Morgan, CR, Lazarow, A: Immunoassay of insulin: Two antibody systems. Plasma insulin levels in normal, subdiabetic and diabetic rats. Diabetes 1963; 12:115126.Google Scholar
6.Bothe, J: 1973 study shows contamination in multiple dose vials. AORN J 1973; 17:111114.Google Scholar
7.Ridgway, JF, McAuliff, WK: The sterility of multiple dose is challenged. Hospital Management 1967; 104:6772.Google Scholar
8.Sheth, HK, Post, GT, Wishiewski, TB, et al: Multidose vials versus single-dose vials: A study in sterility and cost effectiveness. J Clin Microbiol 1983; 17:377379.Google Scholar
9.Lehmann, CR: Effect of refrigeration on bactericidal activity of four preserved multiple-dose injectable drug products. Am J Hosp Pharm 1977; 34:11961200.Google Scholar
10.Hodge, RH, Krangaord, L, Sande, MA, et al: Multiple use of disposable insulin syringe needle units. JAMA 1980; 244:266267.Google Scholar
11.Collins, BJ, Richardson, SC. Spence, BK, et al: Safety of reusing disposable plastic insulin syringes. Lancet 1983; 559561.Google Scholar
12.Highsmith, AK, Anderson, RL, West, CM, et al: Characterization of an endotoxin-like substance recovered from an intravenous antibiotic solution involving pyrogenic reactions, in Cohen, E (ed): Biomedical Applications of the Horseshoe crab (Limuidae), New York, Alan R Liss, 1979; p 465.Google Scholar
13.Highsmith, AK, Greenhood, GP, Allen, IR: Growth of nosocomial pathogens in multidose parenteral medication vials. J Clin Microbiol 1982; 15:10241028.Google Scholar