Hostname: page-component-7c8c6479df-ws8qp Total loading time: 0 Render date: 2024-03-28T10:17:42.663Z Has data issue: false hasContentIssue false

An Outbreak of Needlestick Injuries in Hospital Employees Due to Needles Piercing Infectious Waste Containers

Published online by Cambridge University Press:  02 January 2015

Anne M. Anglim
Affiliation:
The University of Virginia Health Sciences Center, Charlottesville, Virginia
June E. Collmer
Affiliation:
The University of Virginia Health Sciences Center, Charlottesville, Virginia
T. Joel Loving
Affiliation:
The University of Virginia Health Sciences Center, Charlottesville, Virginia
Kenneth A. Beltran
Affiliation:
The University of Virginia Health Sciences Center, Charlottesville, Virginia
Betty J. Coyner
Affiliation:
The University of Virginia Health Sciences Center, Charlottesville, Virginia
Karim Adal
Affiliation:
The University of Virginia Health Sciences Center, Charlottesville, Virginia
Janine Jagger
Affiliation:
The University of Virginia Health Sciences Center, Charlottesville, Virginia
Nikolas J. Sojka
Affiliation:
The University of Virginia Health Sciences Center, Charlottesville, Virginia
Barry M. Farr*
Affiliation:
The University of Virginia Health Sciences Center, Charlottesville, Virginia
*
Box 473, University of Virginia Health Sciences Center, Charlottesville, VA 22908.

Abstract

Objectives:

To investigate the cause of an outbreak of needlestick injuries (NSIs) in hospital employees.

Setting:

A 700-bed university hospital.

Design:

Outbreak investigation, laboratory evaluation of a medical waste disposal device, cost analysis.

Methods:

Employee health department records were reviewed of workers suffering sticks from needles piercing fiberboard-contaminated material containers (CMCs). A laboratory evaluation of needle-puncture resistance properties of the CMCs was performed using a testing apparatus. The cost of a hospital waste disposal program using fiberboard CMCs was compared with the cost of a program using rigid plastic (polypropylene) boxes.

Results:

During 40 months of surveillance in 1986 and from 1989 to 1991, only one NSI had occurred from a needle piercing a CMC. During 9 months in 1993, 13 NSIs occurred due to needles piercing CMCs (P<.001). No clinical illness resulted from the NSIs. The outbreak was halted by a temporary change to plastic (polypropylene) boxes for sharps disposal ($4.92 to $23.33/cu ft) until receipt of a box with a newly designed solid fiberboard liner ($1.25/cu ft). CMC liners used during the epidemic had a mean needle puncture resistance of 527 g, as compared with 660 g for liners used before the outbreak (P<.001). The new solid fiberboard liner has a mean puncture resistance of 1,765 g. A program of waste disposal using fiberboard CMCs was found to cost approximately one-seventh the cost of a program using plastic boxes for disposal of infectious waste.

Conclusion:

A program for infectious waste disposal using fiberboard CMCs can be safe and cost-effective if appropriate standards for puncture resistance are met.

Type
Original Articles
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1995

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Weinstein, SA. Disposable needle and syringe containers. Infect Control 1985;6:4143.Google Scholar
2.Seeff, LB, Wright, EC, Zimmerman, HJ, et al.Type B hepatitis after needle-stick exposure: prevention with HBIG. Final report from the VA cooperative study. Ann Intern Med 1978;88:285293.Google Scholar
3.Meyers, JD, Dienstag, JL, Purcell, RH, Thomas, ED, Holmes, KK. Parenterally transmitted non-A non-B hepatitis: an epidemic reassessed. Ann Intern Med 1977;87:5759.Google Scholar
4.Kiyosawa, K, Sodeyama, T, Tanaka, E, et al.Hepatitis C in hospital employees with needlestick injuries. Ann Intern Med 1991;115:367369.Google Scholar
5.McCray, E. Occupational risk of the acquired immunodeficiency syndrome among health care workers. N Engl J Med 1986;314:11271132.Google Scholar
6.Becker, CE, Cone, JE, Gerberding, JL. Occupational infection with human immunodeficiency virus. Ann Intern Med 1989;110:653656.Google Scholar
7.McCormick, RD, Maki, DG. Epidemiology of needle-stick injuries in hospital personnel. Am J Med 1981;70:928932.Google Scholar
8.Neuberger, JS, Harris, JA, Kundlin, WD, Bischone, A, Chin, TDY. Incidence of needlestick injuries in hospital personnel: implications for prevention. Am J Infect Control 1984;12:171176.Google Scholar
9.Jagger, J, Hunt, EH, Brand-Elnaggar, J, Pearson, RD. Rates of needle-stick injury caused by various devices in a university hospital. N Engl J Med 1988;319:284288.Google Scholar
10.Centers for Disease Control. Guidelines for Prevention of Transmission of Human Immunodeficiency Virus and Hepatitis B Virus to Health-Care and Public-Safety Workers—A Response to PL 100-607. The Health Omnibus Programs Extension Act; 1988. Department of Health and Human Services, February 1989. DHHS (NIOSH) publication no. 89-109.Google Scholar
11.Occupational Safety and Health Administration. Occupational exposure to bloodborne pathogens; final rule (29 CFR 1910.1030). Federal Register. December 6, 1991;56(235):6417564182.Google Scholar
12.Ribner, BS, Landry, MN, Gholson, GL, Linden, LA. Impact of a rigid, puncture resistant container system upon needlestick injuries. Infect Control 1987;8:6366.Google Scholar
13.Krasinski, K, LaCouture, R, Holzman, RS. Effect of changing needle disposal systems on needle puncture injuries. Infect Control 1987;8:5962.Google Scholar
14.Linnemann, CC JrCannon, C, DeRonde, M, Lanphear, B. Effect of educational programs, rigid sharps containers, and universal precautions on reported needlestick injuries in healthcare workers. Infect Control Hosp Epidemiol 1991;12:214219.Google Scholar
15.Loving, TJ. Infectious waste: doing your best for the environment, your employees, and your bottom line. J Healthcare Mat Manage 1992;10:3041.Google Scholar
16.Osterman, CA. Relation of new disposal unit to risk of needle puncture injuries. Hosp Topics 1975;53:1213.Google Scholar
17. Department of Transportation. DOT Hazardous Materials Guide (49 CFR 178.210).Google Scholar
18.Fibre Box Association. Fibre Box Handbook. 20th ed. Rolling Meadows, IL: Fibre Box Association; 1992;126.Google Scholar
19.Rosner, B. Fundamentals of Statistics, 3rd ed. Belmont, CA: Duxbury Press; 1990.Google Scholar
20.British Standards Institution. BS 7320:1990: specifications for sharps containers. London, England: BSI; 1990.Google Scholar
21.American Society for Testing and Materials. Performance standard specifications for puncture resistance of containers for discarded medical needles and other sharps. ASTM Task Force F04.65.01 (in preparation).Google Scholar
22.Emergency Care Research Institute (ECRI). Sharps disposal containers. Health Devices 1993;22:359412.Google Scholar