Skip to main content Accessibility help
×
Home

Effects of xenon on mesenteric blood flow

  • R. Bogdanski (a1), M. Blobner (a1), H. Fink (a1) (a2) and E. Kochs (a1)

Abstract

Summary

Background and objective: The effects of xenon on mesenteric vascular resistance have not been investigated. Because human beings anaesthetized with xenon show good cardiovascular stability, we believed that the agent would have little or no effect on vascular resistance in the splanchnic bed. We determined the effects of different inhaled xenon concentrations on mesenteric blood flow and mesenteric oxygen consumption in pigs sedated with intravenous propofol.

Methods: Twenty-three minipigs were instrumented with transit time flow probes around the pulmonary and superior mesenteric arteries as well as with pulmonary artery and portal venous catheters. A 14 h recovery was allowed followed by recordings of baseline values. Xenon was then randomly administered in 0.30, 0.50, and 0.70 end-tidal fractions.

Results: The administration of xenon resulted in an 8% (not dose dependent) decrease in mean arterial pressure (from 99 ± 15 to 91 ± 19 mmHg; P < 0.05), a 20% decrease in calculated systemic oxygen consumption (from 0.23 ± 0.07 to 0.19 ± 0.04 L min−1; P < 0.01), a 20% reduction in mesenteric oxygen delivery (from 41 ± 12 to 33 ± 11 mL min−1; P < 0.001), a 37% reduction in mesenteric metabolic rate of oxygen (from 11.3 ± 3.6 to 7.1 ± 3.2 mL min−1; P < 0.01) and an 8% decrease in mesenteric artery blood flow (0.22 ± 0.07 to 0.20 ± 0.07 L min−1; P < 0.05) in a dose-dependent fashion. Heart rate, cardiac output, systemic vascular resistance, mesenteric vascular resistance, mesenteric oxygen extraction fraction and portal lactate concentration were not significantly altered by xenon.

Conclusions: Xenon inhalation in the propofol-sedated pig had no measurable effects on mesenteric vascular resistance. This finding may partly explain the well-known cardiovascular stability observed in patients anaesthetized with xenon. Although mesenteric artery blood flow and mesenteric oxygen delivery decreased during xenon administration, unchanged mesenteric oxygen extraction fraction and portal lactate suggest that metabolic regulation of the splanchnic circulation remained unaltered.

Copyright

Corresponding author

Correspondence to: Manfred Blobner, Klinik für Anaesthesiologie der Technischen Universität München, Klinikum rechts der Isar, Ismaningerstr. 22, D-81675 Munich, Germany. E-mail: manfred.blobner@lrz.tum.de

References

Hide All

References

Boomsma F, Rupreht J, Man in 't Veld AJ, de Jong FH, Dzoljic M, Lachmann B. Haemodynamic and neurohumoral effects of xenon anaesthesia. A comparison with nitrous oxide. Anaesthesia 1990; 45: 273278.
Cullen SC, Eger EID, Cullen BF, Gregory P. Observations on the anesthetic effect of the combination of xenon and halothane. Anesthesiology 1969; 31: 305309.
Lachmann B, Armbruster S, Schairer W, et al. Safety and efficacy of xenon in routine use as an inhalational anaesthetic. Lancet 1990; 335: 14131415.
Dingley J, Ivanova-Stoilova TM, Grundler S, Wall T. Xenon: recent developments. Anaesthesia 1999; 54: 335346.
Nakata Y, Goto T, Morita S. Comparison of inhalation inductions with xenon and sevoflurane. Acta Anaesthesiol Scand 1997; 41: 11571161.
Goto T, Saito H, Nakata Y, Uezono S, Ichinose F, Morita S. Emergence times from xenon anaesthesia are independent of the duration of anaesthesia. Br J Anaesth 1997; 79: 595599.
Lane GA, Nahrwold ML, Tait AR, Taylor-Busch M, Cohen PJ, Beaudoin AR. Anesthetics as teratogens: nitrous oxide is fetotoxic, xenon is not. Science 1980; 210: 899901.
Luttropp HH, Romner B, Perhag L, et al. Left ventricular performance and cerebral haemodynamics during xenon anaesthesia. A transoesophageal echocardiography and transcranial Doppler sonography study. A minimal-flow system for xenon anesthesia. Anaesthesia 1993; 48: 10451049.
Jacob L, Boudaoud S, Payen D, et al. Isoflurane, and not halothane, increases mesenteric blood flow supplying esophageal ileocoloplasty. Anesthesiology 1991; 74: 699704.
Andreen M, Irestedt L, Zetterstrom B. The different responses of the hepatic arterial bed to hypovolaemia and to halothane anaesthesia. Acta Anaesthesiol Scand 1977; 21: 457469.
Tverskoy M, Gelman S, Fowler KC, Bradley EL. Intestinal circulation during inhalation anesthesia. Anesthesiology 1985; 62: 462469.
Gelman S, Fowler KC, Smith LR. Regional blood flow during isoflurane and halothane anesthesia. Anesth Analg 1984; 63: 557565.
Gelman SI. The effect of enteral oxygen administration on the hepatic circulation during halothane anaesthesia: experimental investigations. Br J Anaesth 1975; 47: 12531259.
Schindler E, Hempelmann G. Durchblutung und Metabolismus von Leber und Splanchnikusgebiet unter Sevofluran. Anaesthesist 1998; 47 (Suppl 1): S19–23.
Frink EJ Jr, Morgan SE, Coetzee A, Conzen PF, Brown BR Jr. The effects of sevoflurane, halothane, enflurane, and isoflurane on hepatic blood flow and oxygenation in chronically instrumented greyhound dogs. Anesthesiology 1992; 76: 8590.
O'Riordan J, O'Beirne HA, Young Y, Bellamy MC. Effects of desflurane and isoflurane on splanchnic microcirculation during major surgery. Br J Anaesth 1997; 78: 9596.
Marx T, Froeba G, Wagner D, et al. Effects on haemodynamics and catecholamine release of xenon anaesthesia compared with total i.v. anaesthesia in the pig. Br J Anaesth 1997; 78: 326327.
Stowe DF, Rehmert GC, Kwok WM, Weigt HU, Georgieff M, Bosnjak ZJ. Xenon does not alter cardiac function or major cation currents in isolated guinea pig hearts or myocytes. Anesthesiology 2000; 92: 516522.
Hettrick DA, Pagel PS, Kersten JR, et al. Cardiovascular effects of xenon in isoflurane-anesthetized dogs with dilated cardiomyopathy. Anesthesiology 1998; 89: 11661173.
Lynch C III, Baum J, Tenbrinck R. Xenon anesthesia. Anesthesiology 2000; 92: 865868.
Hellebrekers LJ, Liard JF, Laborde AL, Greene AS, Cowley AWM Jr. Regional autoregulatory responses during infusion of vasoconstrictor agents in conscious dogs. Am J Physiol 1990; 259: H12701277.
Granger DN, Granger HJ. Systems analysis of intestinal hemodynamics and oxygenation. Am J Physiol 1983; 245: G786796.
Shepherd AP. Intestinal blood flow autoregulation during foodstuff absorption. Am J Physiol 1980; 239: H156162.
Froeba G. Neue Aspekte der Xenonanaesthesie. Anaesthesiologie Intensivmedizin Notfallmedizin Schmerztherapie 1998; 33 (Suppl 3): 507.
Reinelt H, Schirmer U, Marx T, Topalidis P, Schmidt M. Diffusion of xenon and nitrous oxide into the bowel. Anesthesiology 2001; 94: 475477.
Cevese A, Grasso R, Poltronieri R, Schena F, Vacca G. Peripheral blood flows during colorectal distension in anaesthetised dogs. Pflugers Arch 1993; 424: 488493.
Nakata Y, Goto T, Saito H, et al. Plasma concentration of fentanyl with xenon to block somatic and hemodynamic responses to surgical incision. Anesthesiology 2000; 92: 10431048.
Megens AA, Canters LL, Awouters FH, Niemegeers CJ. Is in vivo dissociation between the antipropulsive and antidiarroheal properties of opioids in rats related to gut selectivity? Arch Int Pharmacodyn Ther 1989; 298: 220229.
Hartman JC, Olszanski DA, Hullinger TG, Brunden MN. In vivo validation of a transit-time ultrasonic volume flow meter. J Pharmacol Toxicol Methods 1994; 31: 153160.
Blobner M, Bogdanski R, Kochs E, Henke J, Findeis A, Jelen-Esselborn S. Effects of intraabdominally insufflated carbon dioxide and elevated intraabdominal pressure on splanchnic circulation: an experimental study in pigs. Anesthesiology 1998; 89: 475482.
Blobner M, Bogdanski R, Jelen-Esselborn S, Henke J, Erhard W, Kochs E. Viszerale Resorption von intraabdominell insuffliertem Kohlendioxid beim Schwein. Anasthesiol Intensivmed Notfallmed Schmerzther 1999; 34: 9499.
Fink H, Blobner M, Bogdanski R, Hanel F, Werner C, Kochs E. Effects of xenon on cerebral blood flow and autoregulation: an experimental study in pigs. Br J Anaesth 2000; 84: 221225.

Keywords

Effects of xenon on mesenteric blood flow

  • R. Bogdanski (a1), M. Blobner (a1), H. Fink (a1) (a2) and E. Kochs (a1)

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed