A large Legionnaires' disease outbreak in Pamplona, Spain: early detection, rapid control and no case fatality

  • J. CASTILLA (a1) (a2), A. BARRICARTE (a1) (a2), J. ALDAZ (a1), M. GARCÍA CENOZ (a1), T. FERRER (a1), C. PELAZ (a3), S. PINEDA (a4), B. BALADRÓN (a3), I. MARTÍN (a4), B. GOÑI (a1), P. ARATAJO (a5), J. CHAMORRO (a5), F. LAMEIRO (a6), L. TORROBA (a5), I. DORRONSORO (a6), V. MARTÍNEZ-ARTOLA (a5), M. J. ESPARZA (a7), M. A. GASTAMINZA (a1), P. FRAILE (a1) and P. ALDAZ (a1)...

Summary

An outbreak of Legionnaire's disease was detected in Pamplona, Spain, on 1 June 2006. Patients with pneumonia were tested to detect Legionella pneumophila antigen in urine (Binax Now; Binax Inc., Scarborough, ME, USA), and all 146 confirmed cases were interviewed. The outbreak was related to district 2 (22 012 inhabitants), where 45% of the cases lived and 50% had visited; 5% lived in neighbouring districts. The highest incidence was found in the resident population of district 2 (3/1000 inhabitants), section 2 (14/1000). All 31 cooling towers of district 2 were analysed. L. pneumophila antigen (Binax Now) was detected in four towers, which were closed on 2 June. Only the strain isolated in a tower situated in section 2 of district 2 matched all five clinical isolates, as assessed by mAb and two genotyping methods, AFLP and PFGE. Eight days after closing the towers, new cases ceased appearing. Early detection and rapid coordinated medical and environmental actions permitted immediate control of the outbreak and probably contributed to the null case fatality.

  • View HTML
    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      A large Legionnaires' disease outbreak in Pamplona, Spain: early detection, rapid control and no case fatality
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      A large Legionnaires' disease outbreak in Pamplona, Spain: early detection, rapid control and no case fatality
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      A large Legionnaires' disease outbreak in Pamplona, Spain: early detection, rapid control and no case fatality
      Available formats
      ×

Copyright

Corresponding author

*Author for correspondence: Dr J. Castilla, Instituto de Salud Pública de Navarra, Leyre 15, 31003 Pamplona, Navarra, Spain. (Email: jcastilc@navarra.es)

References

Hide All
1. Dondero, TJ, et al. An outbreak of Legionnaires' disease associated with a contaminated air-conditioning cooling tower. New England Journal of Medicine 1980; 302: 365370.
2. García-Fulgueiras, A, et al. Legionnaires' disease outbreak in Murcia, Spain. Emerging Infectious Diseases 2003; 9: 915921.
3. Centers for Disease Control and Prevention. Legionnaires' disease associated with cooling towers. Morbidity and Mortality Weekly Report 1994; 43: 491499.
4. Brown, CM, et al. A community outbreak of Legionnaires' disease linked to hospital cooling towers: an epidemiological method to calculate dose of exposure. International Journal of Epidemiology 1999; 28: 353359.
5. Sabria, M, et al. A community outbreak of Legionnaires' disease: evidence of a cooling tower as the source. Clinical Microbiology and Infection 2006; 12: 642647.
6. Blystad, H, Brantsaeter, AB, Lovoll, O. Outbreak of community-acquired legionnaires disease in southeast Norway, May 2005. Eurosurveillance 2005; 10: 127.
7. Barrufet-Barque, MP, et al. Legionnaires' disease outbreak [in Spanish]. Medicina Clinica (Barcelona) 2006; 126: 178182.
8. Nguyen, TM, et al. A community-wide outbreak of legionnaires disease linked to industrial cooling towers – how far can contaminated aerosols spread? Journal of Infectious Diseases 2006; 193: 102111.
9. Rota, MC, et al. Legionnaires' disease outbreak in Rome, Italy. Epidemiology and Infection 2005; 133: 853859.
10. Bhopal, RS, et al. Proximity of the home to a cooling tower and risk of non-outbreak Legionnaires' disease. British Medical Journal 1991; 302: 378383.
11. Mathieu, L, et al. Legionella bacteria in aerosols: sampling and analytical approaches used during the legionnaires disease outbreak in Pas-de-Calais. Journal of Infectious Diseases 2006; 193: 13331335.
12. Watson, JM, et al. Piccadilly Circus legionnaires' disease outbreak. Journal of Public Health Medicine 1994; 16: 341347.
13. Keller, DW, et al. Community outbreak of Legionnaires' disease: an investigation confirming the potential for cooling towers to transmit Legionella species. Clinical Infectious Diseases 1996; 22: 257261.
14. Barricarte, A, et al. Current legionellosis outbreak with 139 cases in Pamplona, Spain. Eurosurveillance 2006; 11: 141.
15. Heymann, DL (ed.). Control of Communicable Diseases Manual, 18th edn. Washington, DC. American Public Health Association, 2004.
16. Pelaz, C, García, L, Martín-Bourgon, C. Legionellae isolated from clinical and environmental samples in Spain (1983–90): monoclonal typing of Legionella pneumophila serogroup 1 isolates. Epidemiology and Infection 1992; 108: 397402.
17. Joly, JR, et al. Development of a standardized subgrouping scheme for Legionella pneumophila serogroup 1 using monoclonal antibodies. Journal of Clinical Microbiology 1986; 23: 768771.
18. Helbig, JH, et al. Pan-European study on culture-proven Legionnaires' disease: distribution of Legionella pneumophila serogroups and monoclonal subgroups. European Journal of Clinical Microbiology and Infectious Diseases 2002; 21: 710716.
19. Fry, NK, et al. Assessment of intercentre reproducibility and epidemiological concordance of Legionella pneumophila serogroup 1 genotyping by amplified fragment length polymorphism analysis. European Journal of Clinical Microbiology and Infectious Diseases 2000; 19: 773780.
20. Baladrón, B, Pelaz, C. Distribution of Legionella pneumophila serogroup 1 AFLP-types of unrelated clinical isolates in Spain. Procedings of the 17th Meeting of the European Working Group on Legionella Infections, Malta, pp. 38, 2002.
21. Lück, PC, et al. Epidemiologic investigation by macrorestriction analysis and by using monoclonal antibodies of nosocomial pneumonia caused by Legionella pneumophila serogroup 10. Journal of Clinical Microbiology 1994; 32: 26922697.
22. Bursed, LJ, et al. A large, travel-associated outbreak of legionellosis among hotel guests: utility of the urine antigen assay in confirming Pontiac fever. Clinical Infectious Diseases 2007; 44: 222228.
23. Addis, DG, et al. Community-acquired Legionnaire's disease associated with a cooling tower: evidence for longer distance transport of Legionella pneumophila. American Journal of Epidemiology 1989; 130: 557568.
24. Den Boer, JW, et al. A large outbreak of Legionnaire's disease at a flower show, the Netherlands, 1999. Emerging Infectious Diseases 2002; 8: 3743.
25. Heath, CH, Grove, DI, Looke, DFM. Delay in appropriate therapy of Legionella pneumonia associated with increased mortality. European Journal of Clinical Microbiology and Infectious Diseases 1996; 15: 286290.
26. Benin, AL, Benson, RF, Besser, RE. Trends in Legionnaires disease, 1980–1998: declining mortality and new patterns of diagnosis. Clinical Infectious Diseases 2002; 35: 10391046.
27. Cayla, JA, et al. A community outbreak of Legionnaires' disease in Barcelona: epidemiologic and environmental study [in Spanish]. Medicina Clinica (Barcelona) 1989; 93: 526530.
28. Storch, G, et al. Sporadic community-acquired Legionnaires' disease in the United States. A case-control study. Annals of Internal Medicine 1979; 90: 596600.
29. Real Decreto del Ministerio de Sanidad y Consumo por el que se establecen los criterios higiénico-sanitarios para la prevención y control de la legionelosis. Real Decreto 865/2003. Boletín Oficial del Estado. July 18, 2003 (http://www.boe.es/boe/dias/2003/07/18/pdfs/A28055-28069.pdf). Accessed 20 May 2007.
30. Ordóñez-Iriarte, JM, et al. Prevalence of Legionella in cooling towers in the community of Madrid [in Spanish]. Medicina Clinica (Barcelona) 2006; 126: 189195.
31. Decreto Foral 54/2006, de 31 de julio, por el que se establecen medidas para la prevención y control de la legionelosis. Boletín Oficial de Navarra n° 96 de 11 de agosto de2006 (http://www.cfnavarra.es/bon/068/bon06096.pdf). Accessed 20 May 2007.

A large Legionnaires' disease outbreak in Pamplona, Spain: early detection, rapid control and no case fatality

  • J. CASTILLA (a1) (a2), A. BARRICARTE (a1) (a2), J. ALDAZ (a1), M. GARCÍA CENOZ (a1), T. FERRER (a1), C. PELAZ (a3), S. PINEDA (a4), B. BALADRÓN (a3), I. MARTÍN (a4), B. GOÑI (a1), P. ARATAJO (a5), J. CHAMORRO (a5), F. LAMEIRO (a6), L. TORROBA (a5), I. DORRONSORO (a6), V. MARTÍNEZ-ARTOLA (a5), M. J. ESPARZA (a7), M. A. GASTAMINZA (a1), P. FRAILE (a1) and P. ALDAZ (a1)...

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed