An indoor system for the study of biological aerosols in open air conditions

Published online by Cambridge University Press:  15 May 2009

A. M. Hood
Affiliation:
Microbiological Research Establishment, Porton Down, Salisbury, Wilts
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

An indoor system designed for the study of survival of airborne micro-organisms in closed conditions has been successfully modified to allow the effect of open air to be measured. It was found that the unidentified open-air factors which are toxic for many species of microbes and rapidly lost when enclosed in conventional laboratory apparatus could be retained in the system by continuous ventilation at an adequate rate. The rate required allowed examination of Escherichia coli in aerosols generated from small amounts of material because of the short periods of ventilation required for appreciable viable decay to occur.

The validity of the system was tested by comparing the survival of E. coli in true aerosols with its survival when the droplets were held on microthread. An investigation of the role of relative humidity in open-air toxicity was included.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1971

References

REFERENCES

Arnold, W. A. (1959). The longevity of the phytotoxicant produced from gaseous ozone-olefin reactions. International Journal of Air Pollution 2, 167.Google ScholarPubMed
Dark, F. A. & Nash, T. (1970). Comparative toxicity of various ozonized olefins to bacteria suspended in air. Journal of Hygiene 68, 245.CrossRefGoogle ScholarPubMed
Druett, H. A. & May, K. R. (1968). Unstable germicidal pollutant in rural air. Nature, London 220, 395.CrossRefGoogle ScholarPubMed
Druett, H. A. & May, K. R. (1969). The open air factor. New Scientist 41, 579.Google Scholar
May, K. R. (1966). Multistage liquid impinger. Bacteriological Reviews 30, 559.CrossRefGoogle ScholarPubMed
May, K. R. & Druett, H. A. (1968). A microthread technique for studying the viability of microbes in a simulated airborne state. Journal of General Microbiology 51, 353.CrossRefGoogle Scholar