Three-dimensional magnetic resonance imaging of congenital cardiac anomalies

Published online by Cambridge University Press:  24 May 2005

Reza S. Razavi
Affiliation:
Cardiac MR Research Group, Division of Imaging Sciences, King's College London, Guy's Hospital, London, UK
Derek L. G. Hill
Affiliation:
Cardiac MR Research Group, Division of Imaging Sciences, King's College London, Guy's Hospital, London, UK
Vivek Muthurangu
Affiliation:
Cardiac MR Research Group, Division of Imaging Sciences, King's College London, Guy's Hospital, London, UK
Marc E. Miquel
Affiliation:
Cardiac MR Research Group, Division of Imaging Sciences, King's College London, Guy's Hospital, London, UK
Andrew M. Taylor
Affiliation:
Cardiac MR Research Group, Division of Imaging Sciences, King's College London, Guy's Hospital, London, UK
Sebastian Kozerke
Affiliation:
Cardiac MR Research Group, Division of Imaging Sciences, King's College London, Guy's Hospital, London, UK
Edward J. Baker
Affiliation:
Cardiac MR Research Group, Division of Imaging Sciences, King's College London, Guy's Hospital, London, UK

Abstract

We describe a new method of three-dimensional magnetic resonance imaging of the heart that has been used to produce high quality diagnostic images in 274 patients with congenital cardiac disease, ranging in age from 1 day to 66 years. Using a steady state free precession gradient echo technique and parallel imaging, rapid acquisition of the entire cardiac volume is possible during 8 to 15 sequential breath-holds, each lasting between 8 and 15 s. We obtained high-resolution images, with a resolution of 1 mm3, at between 3 and 10 phases of the cardiac cycle.

While images of diagnostic quality were obtained in all cases, in 52 patients there was some degradation due to various factors. Children under 8 years were ventilated, and ventilation was suspended for the breath-holds. For patients breathing spontaneously a novel respiratory navigator technique was developed, using a navigator echo placed over the right hemidiaphragm. This was used successfully in 20 patients, and reduced the misalignment of images obtained during different breath-holds.

Images were analysed using multi-planar reformatting and volume rendering. Image processing took approximately five minutes for each study. End-diastolic images were processed for all patients. Systolic images were also processed in selected cases.

Further improvements in parallel imaging should reduce imaging times further, so that it is possible to obtain the full volume image in a single breath-hold. This will enable imaging of complex anatomy to be obtained using a standard imaging protocol that does not require the operator to understand the cardiac malformation, making the magnetic resonance imaging of congenital cardiac disease faster and more effective.

Type
Original Article
Copyright
© 2003 Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Footnotes

Sources of funding: Higher Education Funding Council for England Joint Research Equipment Initiative, Evelina Children's Heart Fund and the Charitable Foundation of Guy's and St Thomas Trust.

References

Razavi R, Baker E. Magnetic resonance imaging comes of age. Cardiol Young 1999; 9: 529538.Google Scholar
Prince MR, Grist TM, Debatin JF. 3D contrast MR angiography. Springer-Verlag, Berlin, 1997.
Miquel ME, Razavi RS, Simon RDB, Hill DLG, Baker EJ, Keevil SF. Three-and four-dimensional reconstruction of intra-cardiac anatomy from two-dimensional magnetic resonance images. Int J Cardiovasc Imaging 2003 July; in press.
Andriantsimiavona R, Griffin LD, Hill DLG, Razavi RS. Simple segmentation of cardiac MR. ISMRM 2003.
Pruessmann KP, Weiger M, Scheidegger MB, Boesiger P. SENSE: sensitivity encoding for fast MRI. Magn Reson Med 1999; 42: 952962.Google Scholar
Kozerke S, Tsao J, Pruessmann KP, Boesiger P. Accelerating cine 3D acquisitions using kt-BLAST. ISMRM 2003.