Abstract

Introduction: Aeromedical helicopters and fixed wing aircraft are used across Canada to transfer patients to definitive care. Given height limitation in aeromedical transport, CPR performance can be affected. An adapted manual compression technique has been proposed by H. Koch (pron. Cook) that uses the elbow to compress the sternum rather than the conventional hand. This preliminary study evaluated the quality of Koch compressions versus conventional bimanual compressions. Methods: Paramedics (5), registered nurses (3) and a physician (1) were recruited. Each participant performed a 2 minute cycle of each technique, were randomized to determine which technique was performed first, and rested 5 minutes between compression cycles. A Resusci Anne SkillReporter manikin atop a stretcher in a BK117 helicopter was used. The compressors performed without feedback or prompting. Outcomes include compression rate, depth, recoil, and fatigue. Results: The mean conventional compression rate was (bpm) 118 +/− 13 versus 111 +/− 10 in the Koch scenario (p=0.02) (target 100 to 120). Mean conventional compression depth (mm) was 44 +/− 9 versus 49 +/− 7 in the Koch scenario (p=0.01) (target 50 to 60). The mean percentage of compressions with complete release in the conventional scenario was 86 +/− 20 versus 84 +/− 22 in the Koch scenario (p=0.9) (target 100%). Using a Modified Borg Scale of 1 to 10, mean provider fatigue after conventional CPR was 7 (+/− 1.6) versus 3 (+/− 1.2) using Koch technique (p<0.001). On average, Koch technique improved the percentage of compressions at target rate by 26%, the percentage at correct depth by 9%, overall compression quality score by 13% and were more less fatiguing. Conclusion: Using an elbow in a height-restricted environment improved compression depth and reduced provider fatigue. From our limited data, Koch compressions appear to improve compression quality. Further study and external validation are required.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      P116: A randomized cross-over trial of conventional bimanual versus single elbow (Koch) chest compression quality in a height-restricted aeromedical helicopter
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      P116: A randomized cross-over trial of conventional bimanual versus single elbow (Koch) chest compression quality in a height-restricted aeromedical helicopter
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      P116: A randomized cross-over trial of conventional bimanual versus single elbow (Koch) chest compression quality in a height-restricted aeromedical helicopter
      Available formats
      ×

Copyright

Corresponding author

*Corresponding author

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed