P056: Non-invasive measurement of the central venous pressure using near-infrared spectroscopy versus point-of-care ultrasound

  • N. Goumeniouk (a1), J. Newbigging (a1), M. McDonnell (a1) and M.L.A. Sivilotti (a1)

Abstract

Introduction: A fundamental hemodynamic parameter, the central venous pressure (CVP) is rarely available in the emergency patient due the delay and risks inherent to central vein cannulation. Recently, two non-invasive strategies have emerged: a) point-of-care ultrasound to supplement traditional inspection the internal jugular waveform ; or b) near-infrared spectroscopy (NIRS) of the external jugular vein. Methods: Five medical students underwent standardized training on both NIRS device (Venus 2000 CVP; Mespere Life Sciences, Waterloo ON) and ultrasound-assisted CVP assessment. During prescheduled, randomly permuted and balanced shifts, a pair of students obtained blinded independent measurements using each device within 10 minutes of each other. High priority subjects likely to have abnormal CVP (e.g. vomiting, dehydrated, heart failure, sepsis) were approached preferentially, followed by a convenience sample of other eligible patients in the emergency department. Secondary outcomes were stopwatch-recorded time from device ready to stable measurement, as well as operator ease, operator confidence and patient discomfort. The blinded treating physician rated each subjects volume status on an ordered scale: depleted, neutral and overloaded. Results: We enrolled 104 patients (median [IQR] age 68 [53, 78] years; 50% male; BMI 27.6 [17.0, 47.7] kg/m2; admission rate 27%) in June-August 2017. Treating physicians classified 17 as volume depleted and 12 overloaded. CVP measurements differed widely between techniques: ultrasound 8 [7, 9] cmH2O (3 cases unobtainable) vs NIRS 12 [8, 17] cmH2O (13 unobtainable). Agreement and correlation between the two devices was extremely low (R2=0.04). While neither technique demonstrated a strong association with the treating physicians estimate of volume status, only the ultrasound values increased monotonically with physician estimate. With regards to secondary outcomes, ultrasound measurements took less time (paired difference 50 seconds [95% CI 7, 93]), and operators were more confident (0.63 [0.02, 1.23] out of 10) and at ease (0.78, [0.13, 1.43]) with ultrasound; patients rated discomfort equally (-0.06 [-0.30, 0.18]). Conclusion: Non-invasive measurement of CVP remains a challenge in the emergency department. The external jugular pressure by NIRS has very high variability and poor agreement with ultrasound-enhanced inspection of the internal jugular, suggesting that this technique is not yet practical for use by non-experts.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      P056: Non-invasive measurement of the central venous pressure using near-infrared spectroscopy versus point-of-care ultrasound
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      P056: Non-invasive measurement of the central venous pressure using near-infrared spectroscopy versus point-of-care ultrasound
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      P056: Non-invasive measurement of the central venous pressure using near-infrared spectroscopy versus point-of-care ultrasound
      Available formats
      ×

Copyright

Corresponding author

*Corresponding author

Keywords

P056: Non-invasive measurement of the central venous pressure using near-infrared spectroscopy versus point-of-care ultrasound

  • N. Goumeniouk (a1), J. Newbigging (a1), M. McDonnell (a1) and M.L.A. Sivilotti (a1)

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed.