LO82: Normal bedside ultrasound of growth plates in healthy children

  • E. Beatty (a1), L. Audette (a1), A. Paré (a1), D. Simonyan (a1), V. Dion (a1), S. Berthelot (a1) and M. Parent (a1)...

Abstract

Introduction: The diagnosis of Salter-Harris Type 1 fractures in the Emergency Department (ED) is primarily clinical, as radiographs are usually unrevealing. We hypothesize that bilateral asymmetry of the growth plate, detected using bedside ultrasound (US), could improve the accuracy of this diagnosis in the ED. This study seeks to determine growth plate size according to age, and to establish normal variation in bilateral symmetry of growth plate cartilage, for the ulna, radius, tibia, and fibula, using bedside US in normal healthy children. Methods: This prospective observational study was conducted in a convenience sample of children ages 0-17 during planned visits to an elementary school, high school, and an outpatient pediatric clinic. A sample size of 177 was determined with a linear regression model using previously published data on the subject. The study was approved by the hospital and universitys ethics board. After a medical questionnaire with a research nurse, the participants underwent ultrasound evaluation of bilateral ulnae, radii, fibulae, and tibiae, to obtain still images of the physes from two orthogonal views. The evaluations were performed by 3 medical residents, 1 medical student, and by the supervising emergency physician. All ultrasonographers were EDE1 certified and specifically trained for growth plate imagery. The still images were evaluated ulteriorly and measurements taken of the physeal cartilage. Ten percent of the patients had their images re-evaluated by the supervising physician to determine inter-rater reliability. Results: A total of 227 patients were recruited. The median age was 8 years old with an interquartile range of (3;14). Mean growth plate size by age was determined, confirming decreasing growth plate size with advancing age for all articulations. The percentage of absolute difference between right and left, for all growth plates together, was a mean of 17% with a 95% CI of 16-19%. The overall inter-rater reliability was excellent at 0.84. Conclusion: This study establishes a reproducible technique of measuring growth plates with ultrasound. We suspect that increased asymmetry at the growth plate, beyond this established normal variation, may signify a physis widening or hematoma consistent with a Salter-Harris Type 1 fracture; this will be evaluated in a second study.

    • Send article to Kindle

      To send this article to your Kindle, first ensure no-reply@cambridge.org is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about sending to your Kindle. Find out more about sending to your Kindle.

      Note you can select to send to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be sent to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

      Find out more about the Kindle Personal Document Service.

      LO82: Normal bedside ultrasound of growth plates in healthy children
      Available formats
      ×

      Send article to Dropbox

      To send this article to your Dropbox account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Dropbox.

      LO82: Normal bedside ultrasound of growth plates in healthy children
      Available formats
      ×

      Send article to Google Drive

      To send this article to your Google Drive account, please select one or more formats and confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your <service> account. Find out more about sending content to Google Drive.

      LO82: Normal bedside ultrasound of growth plates in healthy children
      Available formats
      ×

Copyright

Corresponding author

*Corresponding author

Keywords

Metrics

Full text views

Total number of HTML views: 0
Total number of PDF views: 0 *
Loading metrics...

Abstract views

Total abstract views: 0 *
Loading metrics...

* Views captured on Cambridge Core between <date>. This data will be updated every 24 hours.

Usage data cannot currently be displayed