Hostname: page-component-848d4c4894-ttngx Total loading time: 0 Render date: 2024-05-06T02:08:23.275Z Has data issue: false hasContentIssue false

Total Reflection X-Ray Fluorescence Spectroscopy: Analysis Of Gaas And InGaAs

Published online by Cambridge University Press:  06 March 2019

Leigh Ann Filcs-Sesler
Affiliation:
Texas Instruments P.O. Box 655936, MS 147 Dallas, Texas 75265
Don Plumton
Affiliation:
Texas Instruments P.O. Box 655936, MS 147 Dallas, Texas 75265
Yung-Chung Kao
Affiliation:
Texas Instruments P.O. Box 655936, MS 147 Dallas, Texas 75265
Tae S. Kim
Affiliation:
Texas Instruments P.O. Box 655936, MS 147 Dallas, Texas 75265
Get access

Abstract

This article explores applications of total reflection x-ray fluorescence (TRXRF) to GaAs processes. The applications include determination of surface contamination and InGaAs layer thicknesses. Surface contamination can deteriorate device performance and can occur in starting substrates and in subsequent processing. We demonstrate that TRXRF is a quick, nondestructive method for identifying sulfur contamination on incoming wafers and low levels of metallic impurities from device fabrication. Variable angle TRXRF has been used to determine heterostmeture film thickness, measuring films of InGaAs on GaAs as thin as 4 nm.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1993

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Yoneda, Y. and Horiuchi, T., “Optical flats for use in x-ray speetrochemical microanalysis,” Rev. Sci. Inst. 42(7):1069(1971).Google Scholar
2. Klockenkamper, R., Knoth, J., Prange, A., and Schwenke, H., “Total-reflection X-ray fluorescence spectroscopy,” Anal Chem. 4(23): 1115A (1992).Google Scholar
3. Penka, V. and Hub, W., “Application of total reflection x-ray fluorescence in semiconductor surface analysis,” Spec. Chim. Acta 44B(5):483 (1989).Google Scholar
4. Hoekett, R.S., Metz, J., and Tower, J.P., “The measurement of” trace metal contamination on gallium arsenide substrate surfaces by total reflection x-ray fluorescence (TXRF),“ Semi-Insulating III-V Materials. Proc. 6th Conference, p. 281 (1990).Google Scholar
5. Hockett, R.S., “Surface analysis of trace metals on GaAs by total reflection x-ray fluorescence (TXRF), Proc. Electrochem. Soc. 91:1:183, (1991).Google Scholar
6. Sze, S.M., Physics of semiconductor devices, Second Edition, John Wiley & Sons, New York, p. 21(1981).Google Scholar
7. Martin, G.M., Farges, J. P., Jacob, G., Hallais, J. P., and Poiblaud, G., “Compensation mechanisms in GaAs,“ J. Appl. Phys. 51(5):2840 (1980).Google Scholar
8. Zilko, L. and Williams, R. S., “Auger electron spectroscopy study of GaAs substrate cleaning,“ Electrochem. Soc. 129(2):406 (1982).Google Scholar
9. Shibaya, H., Konda, H., and Tomizawa, K., “Surface contamination level of GaAs wafers treated with solutions of organic base measured by total reflection x-ray fluorescence (TXRF),” Conf. Proc, Chemical Surface Preparation, Passivation and Cleaning for Semiconductor Growth and Processing Symposium, p. 329 (1992).Google Scholar
10. Schaff, W.J. et al., Semiconductors and Semimetals, edited by Pearsall, T.P., Vol, 33, Chap. 2, Academic, New York (1991).Google Scholar
11. Kao, Y.C., Celii, F.G., and Liu, H.Y., “Detection and reduction of indium segregation during molecular beam epitaxial growth of InGaAs/GaAs using in situ reflection mass spectrometry,” J. Vac. Sci. Technol. B11: 1023, (1993)Google Scholar
12. Brunei, M. and Gilles, B., “Grazing incidence x-ray fluorescence,” Colloque de Physique C7(10):85(1989).Google Scholar
13. Schwenke, H., Gutschke, R., Knoth, J., and Kock, M., “Treatment of roughness and concentration gradients in total reflection x-ray fluorescence analysis of surfaces,” Appl. Phys. A54: 460, (1992).Google Scholar